The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ENCLSE FLOOR OPENINGS W/IHR FR | FIRE STOPPAGE NEEDED IN BASEMENT WHERE PIPING PASSES THROUGH MASONRY WALL. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
MICE/RODENTS | BUILDING WITH SEVERE MICE INFESTATION FROM BASEMENT THRU THIRD FLOOR. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | NOT REGISTERED 2006 | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO SIGN POSTED. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | MANAGER REFUDED ENTRY. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR GATE PAD LOCKED. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
REPAIR FENCE | REAR ELEVATION FENCE MISSING TOP RAIL, GATE BROKEN AND LEANING. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | RAER PORCH RECENT ALTERATIONS WITH OUT PERMIT -OBTAIN PLANS AND PERMIT FOR REPAIRS -PLANS MAY BE AVAILABLE ONLINE AT THE CITY OFV CHICAGO WEBSITE FREE OF CHARGE. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S ID SIGN INCOMPLETE, MISSING MAILING ADDRESS. POST CURRENT AND COMPLETE OWNER'S / MANAGEMENT INFORMATION. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT ENTRY DOOR - BROKEN LOCK AND MISSING HANDLE ON INSIDE OF DOOR. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS - TORN AND MISSING WINDOW SCREENS. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
PROVID SELF CLSING SCREEN DVCE | REAR APARTMENT DOORS - MISSING SCREEN DOORS AND CLOSERS. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 5209 APARTMENT 3N REAR DOOR - BROKEN GLASS PANE. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
PARAPET | SOUTH ELEVATION PARAPET WALL - WASHED OUT MORTAR. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | WEST ELEVATION - RUSTED AND DEFLECTING LINTELS. MASONRY PERMIT REQUIRED. REMOVE METAL WRAP COVERING THAT IS CAUSING PREMATURE FAILURE OF LINTELS. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION - BULGING, SHIFTING BRICKS, STEP FRACTURES AND WASHED OUT MORTAR. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR 3 STORY WOOD PORCH WITH DANGEROUS AND HAZARDOUS CONDITIONS.6X6 COLUMNS SET ON CONCRETE SLAB WITH CONCRETE POURED AROUND BASE OF COLUMN, FOUNDATIONS STATUS UNKNOWN.6X6 COLUMNS ARE DOUBLE NOTCHED AT BEAM TO COLUMN CONNECTION AREA.STRINGERS ARE WRAPPED UNDER HEADERS AND NAILED TO JOIST.2X8 JOIST SPAN 10 FEET..6X6 BEAMS SPAN 8 FEET.4X4 COLUMNS USED FOR SUPPORT ARE OVER 12 FEET IN HEIGHT.GUARDRAILS ARE MISSING INTERMEDIATE SUPPORT POST.ENTIRE LANDINGS AND STAIR SYSTEM SWAYS WHEN LATERAL FORCES ARE APPLIED.PLANS AND PERMIT REQUIRED. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | NO PLANS SUBMITTED OR PERMIT APPLIED FOR FOR RECENT REPAIRS TO REAR PORCH. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. NO ENTRY TO VERIFY COMPLAINT OF NO WORKING LIGHTS IN COMMON AREAS AND NO HOT WATER IN BUILDING. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | FILE BUILDING REGISTRATION FOR 2010. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT ENTRY CONCRETE STAIRS - WASHED OUT MORTAR. | 5209 S INDIANA AVE | PERIODIC | FAILED | View |