The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLCE WINDOW PANES, PLEXGLAS | FRONT ENTRY DOOR BROKEN PLATE GLASS | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | GATES CHAINED & LOCKED | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE BROKEN OVERHEAD DOOR PANELS | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY INTERIOR DOORS GATES LOCKED NEED ACCESS VERIFY # UNITS | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT ENTRY DOOR SHATTERED GLASS PANE - BOARDED UP | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - 3 LEVELS - SIGNS OF WOOD ROT AT STRUCTURAL BEAMS AT BEAM END CONNECTION WITH STRUCTURAL COLUMNS. ALSO COLUMNS ARE WITHOUT PROPER FOOTING. EXISTING FOOTING ARE ON THE CONCRETE PATIO SLAB (9" -6' DEEP). ALL STAIR AND PORCH BANISTERS ARE TOO LOW (32"). NO BOLTS AT FOLLOWING CRITICAL JOINT CONNECTIONS (NEWEL POSTS STAIR STRINGERS, RIM BEAMS. ALSO NO FLOOR JOIST HANGERS. ALSO NO STRUCTURAL SHEAR RESISTANT BOLTS AT ANY STRUCTURAL LEDGER BEAMS. | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | FOR ALL PORCH REPAIRS | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | BUILDING IS VACANT - NOTIFY THIS DEPARTMENT AS TO THE PROPOSED USE OF THIS VACANT PROPERTY. | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
CHIMNEY | ALL EXTERIOR PAINTED SURFACES - PEELING PAINT | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH WITH QUESTIONABLE FOOTING UNDER COLUMNS. 2, COLUMNS WITH OUT PROPER LAP JOINTS / BOLTS. 3 BEAMS WITH OUT TIE STRAPS. 4, FRONT HEADER JOISTS NOT BOLTS TO COLUMN OTHERS MISSING THE HANGERS WHERE REQ. 5, STRINGERS NOT BOLTED TO WALL, POST / COLUMN .6 GUARD RAILS LOW, SOME SECTIONS WITH WORSE DISCONNECTED PICKETS. OBTAIN PERMIT TO REPAIR PORCH SYSTEM. | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | 2ND FL APARTMENT WITH LACK OF HYGIENE, NOXIOUS ODORS. | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | ENTIRE BUILDING WITH OUT WATER. | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | ENTIRE BUILDING WITH OUT HOT WATER. | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION AT GRADE SPALLED BRICKS | 7359 N HOYNE AVE | COMPLAINT | FAILED | View |