Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR PORCH UNDER PORCH LATTICE PROTECTING DROP DAMAGED DANGEROUS. | 1617 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 COLUMNS OVERNOTCHED AND ROTTING AT NE CORNER (NEAREST PRIVACY WALL); STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; STRINGERS, DECKS, AND LANDINGS LEANING FROM 1ST TO 3RD FLOOR; LOOSE RAILS AT 3RD FLOOR; 2ND FLOOR RAILS DEFLECTING; 3RD FLOOR RAIL HEIGHT ONLY 32"; TREADS, DECKBOARDS WORN, ROTTING, PAINT PEELING AT 1ST FLOOR; VERY WEAK, LOOSE LANDING BETWEEN 2ND AND 3RD FLOORS; PRIVACY WALL (NORTH) ROTTING. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 1617 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1617 SECOND FLOOR FRONT UNIT SMOKE DETECTOR BEEPING;ALL STAIRWELLS SMOKE DETECTORS BEEPING. | 1617 S SAWYER AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | GRILLES, JUNK, GARBAGE STORED IN ALL STAIRWELLS. | 1617 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | FRONT MAIN ENTRANCE DOOR HARDWARE DAMAGED | 1617 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - WEST ELEVATION LARGE SHELF ANGLES AND LINTELS SEVERELY RUSTING CAUSING DAMAGED AND LARGE JOINTS TO SURROUNDING BRICK, LARGE STRESS CRACKS, WIDE JOINTS.SOUTH ELEVATION PARAPET WALL WASHED OUT MORTAR.PLANS AND PERMITS FOR ALL MASONRY AND SHELF ANGLE AND LINTEL REPAIRS. | 1617 S SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE,UNVERIFIED DETECTORS. | 1617 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 COLUMNS OVERNOTCHED AND ROTTING AT NE CORNER (NEAREST PRIVACY WALL); STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; STRINGERS, DECKS, AND LANDINGS LEANING FROM 1ST TO 3RD FLOOR; LOOSE RAILS AT 3RD FLOOR; 2ND FLOOR RAILS DEFLECTING; 3RD FLOOR RAIL HEIGHT ONLY 32"; TREADS, DECKBOARDS WORN, ROTTING, PAINT PEELING AT 1ST FLOOR; VERY WEAK, LOOSE LANDING BETWEEN 2ND AND 3RD FLOORS; PRIVACY WALL (NORTH) ROTTING. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 1617 S SAWYER AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | BACK HALLWAY CARBON MONOXIDE DETECTOR LOW BATTERY. | 1617 S SAWYER AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | LEAKING STEAM LINE BELOW SW RADIATOR IN 1ST FLOOR UNIT DUE TO STEAM LEAK, WOOD FLOOR IS SATURATED AND SAGGING UNDER LIVING FLOOR RADIATOR. STEAM LINE IS BEING PROPED UP WITH A PIECE OF WOOD IN BASEMENT. | 1617 S SAWYER AVE | COMPLAINT | FAILED | View |