Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR ROOF | ROOF LEAKING | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
INTERIOR FINISH FIRERESISTANCE | BASEMENT MECHANICAL ROOM WALL CEILING PANELING | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | BASEMENT MECHANICAL AREA NO SMOKE DETECTOR | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | BASEMENT MECHANICAL AREA NO CARBON MONOXIDE DETECTOR | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
INSTALL VENT PIPE FOR TRAP | VENT KITCHEN SINK & LAVATORY 1ST FLOOR ALSO BATH TUB IST FLOOR LOOSE WATER CLOSET 1ST FLOOR | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
OBTAIN PERMIT FOR HOTWATER HTR | RELOCATE WATER HEATER AS TO PROVIDE ACCESS TO MAINTAIN & REPLACE PRESENTLY BEHIND FURNACE | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
OBTAIN PERMIT FOR PLUMBING | TO CORRECT ALL PLUMBING VIOLATIONS | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | A LICENSED & BONDED PLUMBING CONTRACTOR IS REQUIRED | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
STRAP SERVICE CONDUIT | SOUTH EXTERIOR PROPERLY STRAP SERVICE RISER | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | 1ST FLOOR KITCHEN AND BATHROOM GFCI'S IN REQUIRED LOCATIONS (18-27-570.8) | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
SERVICE DROP OUT OF REACH | WEST EXTERIOR SERVICE DROP CONDUCTORS WITHIN NORMAL REACH OF BACK PORCH (REMOVE TEMPORARY WIRES ACROSS BACK OF BUILDING | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | BASEMENT STAIRWELL LIGHT FIXTURE IS HANGING FROM WIRES | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | BASEMENT REMOVE ABANDONED METER SOCKET NEXT TO ELECTRIC PANEL (18-27-110.12(E) | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
CORD TO FIXTURE | BASEMENT REMOVE UNPROVED CORD WIRED LIGHT SOCKET | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
SECURE RACEWAY | BASEMENT PROPERLY STRAP ARMORED CABLE BY ELECTRIC PANEL | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | BASEMENT - MISSING SMOKE DETECTOR | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | BASEMENT - MISSING CARBON MONOXIDE DETECTOR | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | EAST - REMOVE JUNK FROM FRONT LAWN | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
INT WALL/CEILING CHIP PLASTER | BASEMENT- BATHROOM WALLS WITH WATER DAMAGE AT THE BOTTOM | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | BASEMENT TO 1ST FLOOR STAIRS WITHOUT HANDRAILS | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | SOUTH - DOOR AT GRADE WITH FORCED ENTRY DAMAGE, SEE HOLE | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT AREA CURRENTLY BEING USED AS SLEEPING QUARTERS FOR EXTENDED FAMILY, CEILING HEIGHT VARIES AND ALL AREAS UNDER 7'0". DISCONTINUE USE OF BASEMENT AS BEDROOMS | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR SUPPLY CORD TO HVAC HEATER IN BASEMENT | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
APPLIANCE INSIGHT DISCONNECT | PROVIDE DISCONNECT FOR HVAC UNIT IN BASEMENT AREA | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES, WIRING, DEVICES, FITTINGS, AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT BASEMENT AREA - 13-12-380. | 3204 S MILLARD AVE | COMPLAINT | PASSED | View | |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF CONDUIT, BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT BASEMENT AREA WITHOUT PERMIT | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
UNAPPROVED CORDS | REMOVE CORD AND INSTALL APPROVED RACEWAY FOR HVAC UNIT IN BASEMENT AREA | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR. | 3204 S MILLARD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST WOOD STAIRS HAS UNDERSIZED GUARDRAILS 4X4 WOOD SUPPORTS ON SLAB. WEST WOOD STAIRS HAS UNDERSIZED GUARDRAILS INCORRECT RISER HEIGHTS AND TREADS ARE PITCHED OR OUT OF LEVEL. | 3204 S MILLARD AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO GARAGE INTERIOR AND EXTERIOR. | 3204 S MILLARD AVE | COMPLAINT | FAILED | View |
PROVIDE PERMIT TO CORRECT VIOLATIONS. (13.12.360) | 3204 S MILLARD AVE | COMPLAINT | FAILED | View | |
REPAIR INTERIOR WALLS/CEILING | 1ST KITCHEN CEILING WATER DAMAGED WITH HOLE | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
PROVIDE TRAP FOR FIXTURE | NO TRAP UNDER BATHTUB | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | BASEMENT MECHANICAL ROOM JUNK * DEBRIS | 3204 S MILLARD AVE | COMPLAINT | PASSED | View |
INSTALL GFCI TO GARAGE AREAS.(18.27.210.8) | 3204 S MILLARD AVE | COMPLAINT | FAILED | View |