Last Modification Date: 2024-08-30 @ 2:41 PM
PIN: 20342150040000
Property Address: 8019 S EVANS AVE
City - Zip: CHICAGO - 60619
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70120
2023 Tax District: 70001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 14 Violations
Violation Inspector Comments Address Category Status View
REPLCE WINDOW PANES, PLEXGLAS EAST ELEVATION / 2ND FLOOR WINDOW - BROKEN GLASS PANE. 8019 S EVANS AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM EAST ELEVATION / 3 STORY WOOD PORCH / COLUMNS - ERECTED ON CONCRETE BLOCKS. UNABLE TO VERIFY SOME FOUNDATION STATUSES. COLUMN HALF LAP JOINTS MEASURE ONLY 12 INCHES WITH ONLY 2 1/2 INCH BOLTS USED. 4X4 HALF LAP JOINTS - FASTENED WITH NAILS ONLY. JOISTS - FASTENED WITH NAILS ONLY. UPPER ENDS OF STRINGERS - FASTENED WITH NAILS ONLY. TREADS - ROTTING AND CRACKED. DECKING - ROTTING WITH HOLES. ALL RAILING SYSTEMS - FASTENED WITH NAILS ONLY. STAIR SYSTEM MOVES WHEN SHAKEN. PLANS AND PERMIT REQUIRED TO REPLACE ENTIRE PORCH STRUCTTURE. SUBJECT TO FIELD INSPECTION AND APPROVAL. 8019 S EVANS AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO VERIFY CONDITION OF FRONT INTERIOR STAIRWAY AND BASEMENT. 8019 S EVANS AVE COMPLAINT FAILED View
CHIMNEY CAPPING NORTH ELEVATION / CHIMNEY CAPPING - MISSING. 8019 S EVANS AVE COMPLAINT FAILED View
CHIMNEY NORTH ELEVATION / CHIMNEY - WASHED OUT MORTAR WITH LOOSE BRICK WORK. 8019 S EVANS AVE COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS REAR YARD - HIGH WEEDS. 8019 S EVANS AVE COMPLAINT FAILED View
ABANDONED REFRIGERATOR REAR YARD - STORING REFRIGERATOR. 8019 S EVANS AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH, EAST AND WEST ELEVATIONS / EXTERIOR WALLS - SPALLED MASONRY WITH MASONRY FRACTURES AND LOOSE MORTAR. REAR MASONRY GARAGE WALLS - SPALLED MASONRY. 8019 S EVANS AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS WITH AN OUTSIDE TEMPERATURE OF 37DEG.F THE FORCED AIR FURNACE HEATING SYSTEM WAS OFF AND THE THERMOSTAT WAS SET TO 90DEG.F (14X-3-305.1, 14X-8-804.1, 14X-8-804.4 AND 14X-8-804.5) 8019 S EVANS AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY WHILE 37DEG.F OUTSIDE AT 4:03PM IN THE 1ST FLOOR APARTMENT - THE FURNACE WAS OFF AND THE AIR TEMPERATURE IN THE THE LIVING ROOM WAS 68DEG.F AND THE BEDROOM WAS 65DEG.F (14X-8-802.2, 14X-8-802.2.1 AND 14X-8-802.2.2) 8019 S EVANS AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE 1ST FLOOR APARTMENT - THE KITCHEN OVEN WAS OPEN AND ON WITH EXTENSIVE USE OF PORTABLE PLUG-IN SPACE HEATERS FOR PRIMARY HEAT THROUGHOUT (14X-8-802.2) 8019 S EVANS AVE COMPLAINT FAILED View
INSECTS BED BUG INFESTATION THROUGHOUT THE PREMISES - PROPERTY NEEDS TO BE TREATED BY CERTIFIED BED BUG EXTERMINATOR(S) THROUGHOUT THE PREMISES - THE CHICAGO DEPARTMENT OF BUILDINGS WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION AND PROOF OF EXTERMINATOR'S QUALIFICATIONS SPECIFICALLY WITH REGARD TO BED BUGS 8019 S EVANS AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR REAR 3-STORY OPEN WOOD STAIR WITH ROOF AND BASEMENT ACCESS -(1) JOIST CONNECTIONS ARE ONLY FACE NAILED OR TOE NAILED(2) SINGLE BEAMS ARE UNDERSIZED(3) COLUMNS BEAR ON CONCRETE BLOCKS WITH UNKNOWN FOUNDATIONS(4) STRINGERS CONNECTIONS TO POST, COLUMNS AND RIM JOIST ARE ONLY FACE NAILED OR TOE NAILED(5) DRAWINGS ARE REQUIRED TO OBTAIN THE PERMIT 8019 S EVANS AVE COMPLAINT FAILED View
PLANS & PERMITS REQUIRED 1ST FLOOR APARTMENT -(1) INTERIOR RENOVATION INCLUDING NEW WALLS CREATING SPACES WITH PLUMBING AND ELECTRICAL SYSTEMS MODIFIED AND UPGRADED WITH NO DRAWINGS OR PERMITS ON FILE(2) FORCED AIR FURNACE SYSTEM INSTALLED REPLACING THE ORIGINAL HEATING SYSTEM WITH NO DRAWINGS OR PERMITS ON FILE(3) DRAWINGS ARE REQUIRED TO OBTAIN THE PERMIT 8019 S EVANS AVE COMPLAINT FAILED View