Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | WEST: ERODED MORTAR | 5427 S HARPER AVE | PERIODIC | PASSED | View |
REPLACE D&H PORCH | 5427: COLUMNS OVERNOTCHED, SEPARATING AT CONNECTION TO BEAMS AND SITTING ON UNSTABLE BLCOK FOUNDATIONS; STRINGERS OVERCUT, CRACKED; JOISTS AND BEAMS OVERSPANNED; GUARD RAILS UNDER 42" WITH WEAK RAILS AND FAILING CONNECTIONS; 5429: COLUMNS OVERNOTCHED, STACKED; DEFICIENT BEAM-COLUMN CONNECTION, SEPARATING; ROTTED, LOOSE TREADS AND RISERS; MISSING ALL REQUIRED HARDWARE; 5431: STRINGERS ROTTED, OVERCUT, AND PULLING OUT OF POSITION; SEVERE DEFLECTION AT GUARD RAILS; COLUMNS OVERNOTCHED; JOISTS AND BEAMS OVERSPANNED; OBTAIN PLANS AND PERMITS TO REPLACE THREE D/H PORCH SYSTEMS | 5427 S HARPER AVE | PERIODIC | PASSED | View |
POST OWNER/MANAGERS NAME/# | POST MANAGEMENT INFO. | 5427 S HARPER AVE | PERIODIC | PASSED | View |
MAINTAIN WINDOW SASH | ALL ELEVATIONS: ROTTED WINDOW SASH | 5427 S HARPER AVE | PERIODIC | PASSED | View |
FLAKY INTERIOR PAINT | WINDOW FRAMES: PEELING PAINT | 5427 S HARPER AVE | PERIODIC | PASSED | View |
RAT STOP AROUND EXTERIOR | EXTERMINATE FOR RODENTS | 5427 S HARPER AVE | PERIODIC | PASSED | View |
PARAPET | NORTH AND SOUTH ELEVATIONS / PARAPET WALL / MULTIPLE LOCATIONS / MASONRY - BULGING AND SHIFTING; WASHED OUT MORTAR. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW | WEST ELEVATION BASEMENT AND MOST COURTYARD WINDOWS - ROTTED WOOD SASH AND FRAMES. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPAIR BALCONY | FRONT ELEVATION / 2ND AND 3RD FLOORS / ALL METAL BALCONIES - SEVERELY RUSTED; SPALLING MASONRY. PERMIT ONLY REQUIRED FOR BALCONIES REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL BY IRON BUREAU. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | INTERIOR STAIRWAYS / MULTIPLE LOCATIONS / SMOKE DETECTORS - OUT OF SERVICE WITH LOW BATTERIES. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF DWELLING UNITS - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. 5431 S. / 2ND FLOOR BACK - NO ENTRY, UNABLE TO VERIFY COMPLAINT OF OLD STOVE OBSTRUCTING PATH OF EGRESS. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SR#801879516/ COURTYARD OPEN MORTAR JOINTS AND SPALLING BRICKS | 5427 S HARPER AVE | COMPLAINT | PASSED | View |
REPAIR CORNICE | COURTYARD DECORAVTIVE LIMESTONE MISSING MORTAR. NO ENTRY TO VERIFY OCCUPANCY SMOKE, AND CARBON DETECTORS | 5427 S HARPER AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | 5429 3RD FLOOR COURTYARD WINDOW FRAMES PEELING AND DAMAGED. | 5427 S HARPER AVE | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | COURTYARD VARIOUS LOCATION WHERE CAPPING IS MISSING WINDOW SILLS ROTTED | 5427 S HARPER AVE | COMPLAINT | PASSED | View |
REPAIR BALCONY | ALL ELEVATION WEST BALCONIES RUSTED GUARD RAILS, BRACING AND UNDERSIDE RUSTED AND DAMAGED 2ND AND 3RD FLOOR 5427 AND 5431 | 5427 S HARPER AVE | COMPLAINT | PASSED | View |
FILE BLDG REGISTRATION | NOT REGISTERED 2011 | 5427 S HARPER AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | SOME UNITS SCREEN MISSING VARIOUS LOCATIONS 1-3 | 5427 S HARPER AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALKS BROKEN UNEVEN CONCRETE | 5427 S HARPER AVE | PERIODIC | FAILED | View |
RATS | RATS DROPPINGS SITE IN BASEMENT AREAS | 5427 S HARPER AVE | PERIODIC | PASSED | View |
RAT STOP AROUND EXTERIOR | RAT PROOF BUILDING | 5427 S HARPER AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR STAIR | REAR EXTERIOR STAIRS GRADE TO BASEMENT SPALLED CONCRETE TREADS AND NO RAILS | 5427 S HARPER AVE | PERIODIC | FAILED | View |
DEFECTIVE OUTLETS | BASEMENT LAUNDRY ROOMS NO GFCI OUTLETS | 5427 S HARPER AVE | PERIODIC | PASSED | View |
DEBRIS, EXCESSIVE | EXCESSIVE STORAGE ON REAR PORCHES | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCHES (3) SOME POSTS AND COLUMNS NOT ON FOUNDATION, DECK JOISTS UNDERSIZED SUPPORT BEAMS NOT SUPPORTED PROPERLY, MOST COLUMN NOT LAPPED AND BOLTED, GUARDRAILS NOT 42" AND DEFLECT UNFERLOADS STAIRS SOME WEAK TREADS AND OVERCUT STRINGERS, VARIOUS LOCATION ALL LEVELS DECK NAILS POPPING | 5427 S HARPER AVE | PERIODIC | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | STRUCTURAL ENGINEERS REPORT AN REAR PORCHES (3) 2 COPIES SUBMITTED TO DEPARTMENT OF BUILDING AT 120 N RACINE CHGO ILL | 5427 S HARPER AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PERMITS FOR PORCH REPAIR OR REPLACEMENT | 5427 S HARPER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO APARTMENT UNITS ON FRONT STAIRWAYS | 5427 S HARPER AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | #5427 - PEDESTAL SINK ON 2ND FLOOR DECK; A/C UNIT ON 3RD FLOOR DECK#5431 - A/C UNIT ON 1ST FLOOR DECK | 5427 S HARPER AVE | PERIODIC | FAILED | View |
FLAKY INTERIOR PAINT | KITCHEN - PEELING, BUBBLING, HANGING PAINT; INTERIOR STAIRWELL - PEELING PAINT AT 3RD FLOOR CEILING | 5427 S HARPER AVE | PERIODIC | FAILED | View |
PARAPET | PARAPET WALL - LEANING; WASHED OUT MORTAR, SPALLING BRICKS. PERMIT REQUIRED TO REPAIR PARAPET WALL. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - LOOSE TREAD FROM 1ST TO 2ND FLOOR. (PORCH COMPLIED 3/31/2008 BY BL00947). | 5427 S HARPER AVE | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAILS MISSING AT GRADE FOR BASEMENT AREAWAY. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | KITCHEN - LOOSE PLASTER; #5429 - CRACKS, HOLES IN WALLS THRU-OUT INTERIOR STAIRWELL | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPUTTY WINDOW PANES | WINDOW TRIM - ROTTING | 5427 S HARPER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. UNABLE TO INSPECT #5427 INTERIOR, STAIRWELL, APARTMENTS, BASEMENT. APARTMENT 3W APPEARS VACANT. UNVERIFIED DETECTORS AND OCCUPANCY. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPAIR OR REPLACE | KITCHEN - DRAWER MISSING AT BASE CABINET; BATHROOM - CABINET NOT SECURED TO WALL; ROTTING AT BOTTOM.(SEC. 7-28-060) | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REMOVE | DECORATIVE OWL HANGING FROM 2ND FLOOR OVER FRONT ENTRANCE; UNSECURED. REMOVE (SEC. 7-28-060) | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR - HANGING | 5427 S HARPER AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | CARBON MONOXIDE DETECTOR - MISSING | 5427 S HARPER AVE | PERIODIC | FAILED | View |
RESTORE EXIT AND EM | EMERGENCY LIGHTS - NOT WORKING AT TIME OF INSPECTION. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
STOP LEAKING WATER | KITCHEN - WATER LEAKING AT CEILING | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | BATHROOM - SHOWERHEAD, SINK - WATER LEAKING AT FIXTURES. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | BATHROOM - TOILET CLOGGED UP | 5427 S HARPER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 5427 BASEMENT WINDOWS, BROKEN PANES, 1ST AND 2ND FLOOR STORM WINDOWS, BROKEN FRAMES. | 5427 S HARPER AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 1ST FLOOR APARTMENT, LIVING ROOM AND BEDROOM RADIATORS HAVE BROKEN VALVES. | 5427 S HARPER AVE | COMPLAINT | FAILED | View |
REPAIR BALCONY | ALL BROKEN STEEL RUSTED. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | NORTH, EAST, SOUTH PORCHES GRADE TO 3RD FLOOR RAILING, STRINGERS UPRIGHT JOIST ROTTED AND WALK , UPRIGHTS, BUTT SPLICED JOISTS MISSING HANGER TO LONG OF SPAN RAILINGS LESS THAN 423" HIGH. | 5427 S HARPER AVE | PERIODIC | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | ALL PORCHES REPAIRS PLANS AND PERMITS NEEDED. | 5427 S HARPER AVE | PERIODIC | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY MOST UNDER. | 5427 S HARPER AVE | PERIODIC | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S ID SIGN POSTED. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
NO POSTED ADDRESS | BUILDING - POST ADDRESS RANGE OF BUILDING SO IT IS VISIBLE FROM THE STREET. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW | WEST ELEVATION BASEMENT AND MOST COURTYARD WINDOWS - ROTTED WOOD SASH AND FRAMES. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - LOOSE TREAD FROM 1ST TO 2ND FLOOR. (PORCH COMPLIED 3/31/2008 BY BL00947). | 5427 S HARPER AVE | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAILS MISSING AT GRADE FOR BASEMENT AREAWAY. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED FROM 2005 THROUGH 2016. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
REPAIR BALCONY | WEST ELEVATION BALCONYS - RUSTED. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
PARAPET | SOUTH ELEVATION PARAPET WALL AT REAR - MINOR SPALLING BRICKS AND WASHED OUT MORTAR. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS, UNABLE TO VERIFY COMPLAINT OF BED BUGS IN 5431 APARTMENT 3. | 5427 S HARPER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR | 5427 S HARPER AVE | PERIODIC | PASSED | View |
MAINTAIN WINDOW | WEST ELEVATION/WINDOW FRAMES ROTTED 1ST THROUGH 3RD FLOOR. | 5427 S HARPER AVE | COMPLAINT | PASSED | View |
REPAIR DEFECTIVE FOUNDATION | 5431 FOUNDATION WALL CRACKED AND BROKEN/NEAR BASEMENT APARTMENT | 5427 S HARPER AVE | COMPLAINT | PASSED | View |
CHIMNEY | CHIMNEY BRICK FRACTURES | 5427 S HARPER AVE | PERIODIC | PASSED | View |