The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
STOP/REMOVE NUISANCE | REAR AT ALLEY WOOD DEBRIS FROM REAR PORCH ALL OVER GROWN | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH DECKING DEBRIS REPLACED AND OTHER REPAIRS NO PERMIT FOR PORCH REPAIRS RAILS TOO LOW IMPROPER BEAM TO COLUMN CONNECTION | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMITS FOR ALL REPAIR TO BUILDING AND REAR 6 FOOT WOODEN FENCE | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY NO CAP | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR WINDOW BOARDED | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR DOORS BOARDED | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | REAR STAIRS NO LIGHTS | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | NORTH LOOSE DOWNSPOUT SECTION 18-29-1101-2-1 | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 6621 S LANGLEY AVE | COMPLAINT | CLOSED | View | |
SUPPLY HOT WTR MIN TEMP 120DEG | APT. - 1 / GAS SERVICE - SHUT OFF, NO HOT WATER PROVIDED. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
RELOCATE SMOKE DETECTOR | APT. - 1 / SMOKE DETECTOR - LOCATED 4 FEET FROM CEILING. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT FURNACE AREA AND 1ST FLOOR APT. / CARBON MONOXIDE DETECTORS - MISSING | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY AND BASEMENT / SMOKE DETECTORS - MISSING. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | APT. - 1 / GAS SERVICE - SHUT OFF, NO HEAT PROVIDED. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / 2 STORY WOOD PORCH / COLUMNS - ERECTED ON CONCRETE BLOCKS AND ON SOIL. FOUNDATION STATUS - UNKNOWN. COLUMN HALF LAP JOINTS - FASTENED WITH NAILS ONLY. 1ST FLOOR BEAM - SCABBED BLOCK AT EXTERIOR WALL CONNECTION. BEAMS - SEPERATING AT FIRE CUT CONNECTIONS. 2X6 JOISTS SPAN UP TO 10 FEET LONG. DECK JOISTS - SAGGING. 2ND FLOOR STAIR SYSTEM SAGGING OUT OF LEVEL. UPPER ENDS OF STRINGERS - FASTENED WITH NAILS ONLY. 2ND FLOOR LANDING - SUPPORTED BY 4X4 THAT IS ERECTED ON 1ST FLOOR DECKING.WEST ELEVATION / MASONRY PORCH WITH ROOF / GUARDRAIL WALLS - MEASURE 24 INCHES HIGH. HAND RAILS - MEASURE APROX. 24 INCHES HIGH AND HAS MASONRY FRACTURES. PLANS AND PERMIT REQUIRED TO REPLACE REAR 2 STORY WOOD PORCH. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
NATURAL LIGHT NEEDED | BASEMENT WINDOWS - BLOCKED UP WITH STUD FRAME WALLS AND DRYWALL INSTALLED THROUGHOUT. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | 2ND FLOOR KITCH FLOOR - SAGGING. FLOOR TILE CRACKED WITH LOOSE CERMIC TILES. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | APT. - 1 / FRONT AND REAR EXIT DOORS - GAPS ON ALL SIDES. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | 1ST FLOOR APARTMENT HAS BEEN DUPLEXED INTO THE BASEMENT. REAR BEDROOM HAS HAD NEW STAIRS INSTALLED LEADING TO BASEMENT. BASEMENT WINDOWS AND SOUTH EXIT DOOR HAVE BEEN ENCLOSED WITH MASONRY BLOCK. SUBMIT PLANS AND OBTAIN PERMIT TO AUTHORIZE ALTERATIONS TO 1ST FLOOR AND BASMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION / ATTIC TURRET WINDOWS - BROKEN. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | 1ST FLOOR INTERIO DOORS - DAMAGED THROUGHOUT. 1 BEDROOM DOOR - INSTALLED UPSIDE DOWN. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT FURNACE ROOM / DRYWALL WALLS - BLACK SUBSTANCE. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | STAIRS LEADING TO BASEMENT / GUARD RAILS LOOSE AND PULLING WITH LOOSE AND MISSING BALLUSTERS. HEADROOM - NOT 6 FEET 8 INCHES. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
HEATING PLANT ENCLOSURE | BASEMENT FURNACE ROOM WALLS - MISSING DRYWALL. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / 2 STORY WOOD PORCH - WOOD COLUMNS ERECTED ON HOLLOW BLOCK AND DIRT. FOUNDATION STATUS UNKNOWN. COLUMN NOTCHED OUT WITH SCAB BLOCKING. END BEAM SUPPORTED BY 2 X 6 AT BEAM POCKET. END BEAM NOTCHED AROUND MAIN ELECTRIC SUPPLY. 1ST FLOOR DECK IS SAGGING. 2X6 JOISTS SPAN APPROX. 10'. SECOND FLOOR 2X6 JOISTS CRACKED. LOOSE DECKING THROUGHOUT. ENTIRE STRUCTURE MOVES WITH SHAKEN. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | BUILDING / SCREENS - MISSING IN VARIOUS LOCATIONS. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | EAST ELEVATION/ WINDOW FRAMES - ROTTING | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION / MASONRY STAIR - SPALLED TREADS AND DECK. GUARDRAIL KNEEWALL UNDERSIZED.SOUTH ELEVATION / GRADE TO BASEMENT / HANDRAILS ARE MISSING.EAST ELEVATION / GRADE TO BASEMENT / GUARDRAIL AND HANDRAIL - MISSING. | 6621 S LANGLEY AVE | COMPLAINT | FAILED | View |