The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CARB MONOX DETECT IN RESID | CARBON MONOXIDE DETECTORS MISSING IN ALL APARTMENTS. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | CENTER STAIRWAY - WINDOWS BROKEN AT 2ND FLOOR. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR IN CENTER STAIRWAY. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE PLANS AND OBTAIN PERMIT FOR OWNERS UNIT AT 2ND FLOOR REAR. SHOW PARATITION WALLS, PLUMBING AND ELECTRICAL ALSO FOR ATTIC UNITS. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
LIGHT AND VENT | INADEQUATE LIGHT AND VENTILATION AT OWNERS UNIT AND ATTIC UNITS. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' | INADEQUATE CEILING HEIGHT AT OWNERS UNIT 2ND FLOOR REAR AND ATTIC UNITS. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT AND REAR STAIR SYSTEMS: STRINGERS NOT BOLTED TO COLUMNS. RISER BOARDS MISSING. EXCESSIVE SPACING BETWEEN PICKETS. RAIL TOO LOW. RAILS HORIZONTAL. RAIL MISSING TO REAR ATTIC UNIT. OBTAIN PERMIT FOR REPAIRS. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST MANAGEMENT | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BUILDING - POSTED ADDRESS NOT VISIBLE FROM STREET. FIRE AND SAFETY HAZARD. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT AND REAR GATES TO SERVICE WALK / CHAINED AND PAD LOCKED. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 3-STORY / EXTERIOR WOOD PORCH - 4X4 COLUMNS ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. TWO 4X4 COLUMNS SUPPORTING PARTIAL ROOF ENCLOSURE AND LANDING, RESTING ON 1ST FLOOR CANTILIVERE. UPPER ENDS OF STRINGERS, INADEQUATELY SUPPORTED ONLY NAILED THROUGHOUT. STAIR RAILINGS WITH 7 INCH GAPS AT THE BOTTOM.TREADS ROTTED AND CRACKED. RISER JUST BELOW 2ND FLOOR DECK - 10 INCHES HIGH. PLANS AND PERMIT REQUIRED FOR REPLACEMENT OF REAR 3-STORY PORCH. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE; UNVERIFIED DETECTORS, CONDITIONS, OCCUPANCY AND COMPLAINT OF FESTATION OF RODENTS. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BROKEN PLASTER AT CENTER STAIRWAY AT CEILING. | 1721 N KIMBALL AVE | COMPLAINT | FAILED | View |