Last Modification Date: 2024-08-30 @ 4:41 PM
PIN: 16244160240000
Property Address: 2010 S ROCKWELL ST
City - Zip: CHICAGO - 60608
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77115
2023 Tax District: 77001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 25 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# (SR#07-00278191) OWNER'S ID SIGN NOT POSTED 2010 S ROCKWELL ST COMPLAINT PASSED View
SCRAPE/PAINT FIRE ESCAPE EAST ELEVATION: EXTENSION LADDER IS MISSING FROM FIRE ESCAPE, RAIL IS NOT WELDED AT 3RD LEVEL, PICKETS ARE MORE THAN 4 INCHES APART, REMOVE OR REPAIR; OBTAIN PERMIT FOR EITHER CHOICE 2010 S ROCKWELL ST COMPLAINT PASSED View
REPAIR EXTERIOR WALL EAST, SOUTH ELEVATIONS: OPEN MORTAR JOINTS IN EXTERIOR WALL; SOUTH ELEVATION: ERODED MORTAR AT GRADE 2010 S ROCKWELL ST COMPLAINT PASSED View
WORK NOT ALLOWED EAST ELEVATION: NEW MASONRY WORK ON UPPER EAST FACADE, REMOVE WORK PERFORMED WITHOUT PERMIT AND RESTORE BUILDING TO ORIGINAL CONSTRUCTION 2010 S ROCKWELL ST COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR EAST ELEVATION: OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO UPPER EAST FACADE OR RESTORE THE BUILDING TO THE ORIGINAL STATE 2010 S ROCKWELL ST COMPLAINT PASSED View
REPAIR LINTELS EAST ELEVATION: STEEL LINTEL MISSING FROM 3RD FLOOR WINDOW 2010 S ROCKWELL ST COMPLAINT PASSED View
USE SANITARY REFUSE CONTAINERS NORTH ELEVATION: REMOVE DEMO DEBRIS IN SIDE YARD 2010 S ROCKWELL ST COMPLAINT PASSED View
REPAIR FENCE NORTH, EAST ELEVATION: FENCE IS NOT ATTACHED TO TOP RAIL, LEANING 2010 S ROCKWELL ST COMPLAINT PASSED View
SERVICE WALK, PASSAGE, AREAWAY WEST, NORTH ELEVATION: SERVICEWALKS HAVE BEEN REMOVED; OBTAIN PERMIT FOR REPLACEMENT 2010 S ROCKWELL ST COMPLAINT PASSED View
PARAPET SOUTH ELEVATION: OPEN MORTAR JOINTS AT PARAPET WALL 2010 S ROCKWELL ST COMPLAINT PASSED View
CHIMNEY SOUTH ELEVATION: CHIMNEY CAP IS MISSING 2010 S ROCKWELL ST COMPLAINT PASSED View
REPUTTY WINDOW PANES EAST ELEVATION: CAULK IS MISSING AROUND 1ST & 3RD FLOOR WINDOWS 2010 S ROCKWELL ST COMPLAINT PASSED View
REPLACE D&H PORCH NORTH ELEVATION, SIDE PORCH: ENTIRE STRUCTURE IS LEANING, FOUNDATION UNKNOWN, BEAMS ARE INADEQUATELY SUPPORTED AND CONNECTED TO COLUMNS, UNDERSIZED 2X8 JOISTS ARE ROTTING AND SPACED MORE THAN 16 INCHES ON CENTER, RIM JOISTS ARE ROTTING, RAILS ARE LESS THAN 42 INCHES TALL, LEANING AND DANGEROUSLY UNSTABLE! INTERMEDIATE POSTS ARE PULLING AWAY FROM STRUCTURE, PICKETS ARE SPACED MORE THAN 4 INCHES APART, HANDRAIL FROM GRADE TO 1ST IS CRACKED AND SPLIT, TREADS ARE CRACKED, CHIPPED, AND WEAK, 1X1'S ARE USED AS RISERS, NOSING MISSING ON MOST STEPS, DECKBOARDS ARE SPLITTING, BOWED, AND HAVE EXCESSIVE GAPS, THERE IS APPROXIMATELY 5 INCHES BETWEEN DECKBOARDS AND BOTTOM OF PICKETS; WEST ELEVATION, REAR PORCH: PORCH IS LEANING EXCESSIVELY, 2X4'S USED AS COLUMNS AT STRINGERS, BEAMS ARE INADEQUATELY CONNECTED TO COLUMNS, 6X6 BEAMS SPAN OVER 7 FEET, 6X6 BEAMS ON 3RD FLOOR ARE ROTTING, UNDERSIZED 2X6 JOISTS SPAN OVER 23 FEET AND ARE SPACED MORE THAN 16 INCHES IB CENTER, STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMNS, NON-UNIFORM RISER HEIGHT, RISER AT 2ND FLOOR IS BROKEN, RAILS ON 2ND FLOOR ARE LOOSE, RAILS ON 3RD FLOOR ARE OF A LADDER DESIGN, PICKETS ARE MISSING AT HANDRAILS, INTERMEDIATE POST IS MISSING AT 1ST FLOOR RAILING SECTION, HOLES IN DECKBOARDS ARE SPACED EXCESSIVELY ON 2ND AND 3RD FLOOR, DECKBOARDS ON 3RD FLOOR ARE BUTTED AND TOENAILED TO FLOOR JOISTS, BIRD FECES ON 3RD FLOOR RAILS, ALL STAIRS ARE LEANING, CEILING/ROOF HATCH IS ROTTING; SUBMIT PLANS AND OBTAIN PERMIT FOR REPLACEMENT 2010 S ROCKWELL ST COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY WEST ELEVATION: GATE ON PORCH (1ST FLOOR) IS PADLOCKED, PREVENTING REAR EXIT; NORTH: SIDE GATE IS PADLOCKED 2010 S ROCKWELL ST COMPLAINT PASSED View
FLAKY INTERIOR PAINT NORTH ELEVATION: PEELING PAINT ON 8X8 COLUMN; WEST ELEVATION: PEELING PAINT ON REAR PORCH 2010 S ROCKWELL ST COMPLAINT PASSED View
DEBRIS, EXCESSIVE WEST ELEVATION: LAZY BOY CHAIR ON 2ND FLOOR; CHAIRS AND GARBAGE BAGS ON 3RD FLOOR; NORTH: BROKEN CONCRETE IN YARD 2010 S ROCKWELL ST COMPLAINT PASSED View
NO CLOSET/STORAGE UNDER STAIR WEST ELEVATION: BIKES, LUMBER, TRASHM CANS, TOYS ARE STORED UNDERNEATH PORCH 2010 S ROCKWELL ST COMPLAINT PASSED View
REPAIR ROOF STRUCTURE WEST ELEVATION: ROOF HATCH OVER REAR PORCH IS DILAPIDATED AND ROTTING; OBTAIN PERMIT FOR REPAIRS 2010 S ROCKWELL ST COMPLAINT PASSED View
SEND EX. METAL LETTER SUBMIT ENGINEER REPORT 2010 S ROCKWELL ST COMPLAINT FAILED View
PROTECT METAL MEMBERS SCRAPE PAINT 2010 S ROCKWELL ST COMPLAINT FAILED View
F.E. RAILINGS REPAIR AND REPLACE FIRE ESCAPE RAILING AND PLATFORM 2010 S ROCKWELL ST COMPLAINT FAILED View
DEMO DEBRIS NORTH ELEVATION: BROKEN CONCRETE AND BRICKS IN SIDE YARD 2010 S ROCKWELL ST COMPLAINT PASSED View
REPAIR OR REPLACE NORTH ELEVATION: DOWNSPOUT IS MISSING (SEC. 18-29-1101.2.1) 2010 S ROCKWELL ST COMPLAINT PASSED View
STOP/REMOVE NUISANCE EAST ELEVATION: BRICKS ON WINDOW SILL AT 2ND FLOOR 2010 S ROCKWELL ST COMPLAINT PASSED View
FOUNDATION, ADEQUATELY SUPPORT WEST ELEVATION: FOUNDATION AT BASEMENT HAS BEEN BROKEN UP AND REMOVED; OBTAIN PERMIT FOR REPLACEMENT. SERVICE WALK HAS BEEN REMOVED, ALSO. 2010 S ROCKWELL ST COMPLAINT PASSED View