The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | (SR#07-00278191) OWNER'S ID SIGN NOT POSTED | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
SCRAPE/PAINT FIRE ESCAPE | EAST ELEVATION: EXTENSION LADDER IS MISSING FROM FIRE ESCAPE, RAIL IS NOT WELDED AT 3RD LEVEL, PICKETS ARE MORE THAN 4 INCHES APART, REMOVE OR REPAIR; OBTAIN PERMIT FOR EITHER CHOICE | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | EAST, SOUTH ELEVATIONS: OPEN MORTAR JOINTS IN EXTERIOR WALL; SOUTH ELEVATION: ERODED MORTAR AT GRADE | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | EAST ELEVATION: NEW MASONRY WORK ON UPPER EAST FACADE, REMOVE WORK PERFORMED WITHOUT PERMIT AND RESTORE BUILDING TO ORIGINAL CONSTRUCTION | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | EAST ELEVATION: OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO UPPER EAST FACADE OR RESTORE THE BUILDING TO THE ORIGINAL STATE | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
REPAIR LINTELS | EAST ELEVATION: STEEL LINTEL MISSING FROM 3RD FLOOR WINDOW | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
USE SANITARY REFUSE CONTAINERS | NORTH ELEVATION: REMOVE DEMO DEBRIS IN SIDE YARD | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
REPAIR FENCE | NORTH, EAST ELEVATION: FENCE IS NOT ATTACHED TO TOP RAIL, LEANING | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | WEST, NORTH ELEVATION: SERVICEWALKS HAVE BEEN REMOVED; OBTAIN PERMIT FOR REPLACEMENT | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
PARAPET | SOUTH ELEVATION: OPEN MORTAR JOINTS AT PARAPET WALL | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
CHIMNEY | SOUTH ELEVATION: CHIMNEY CAP IS MISSING | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
REPUTTY WINDOW PANES | EAST ELEVATION: CAULK IS MISSING AROUND 1ST & 3RD FLOOR WINDOWS | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | NORTH ELEVATION, SIDE PORCH: ENTIRE STRUCTURE IS LEANING, FOUNDATION UNKNOWN, BEAMS ARE INADEQUATELY SUPPORTED AND CONNECTED TO COLUMNS, UNDERSIZED 2X8 JOISTS ARE ROTTING AND SPACED MORE THAN 16 INCHES ON CENTER, RIM JOISTS ARE ROTTING, RAILS ARE LESS THAN 42 INCHES TALL, LEANING AND DANGEROUSLY UNSTABLE! INTERMEDIATE POSTS ARE PULLING AWAY FROM STRUCTURE, PICKETS ARE SPACED MORE THAN 4 INCHES APART, HANDRAIL FROM GRADE TO 1ST IS CRACKED AND SPLIT, TREADS ARE CRACKED, CHIPPED, AND WEAK, 1X1'S ARE USED AS RISERS, NOSING MISSING ON MOST STEPS, DECKBOARDS ARE SPLITTING, BOWED, AND HAVE EXCESSIVE GAPS, THERE IS APPROXIMATELY 5 INCHES BETWEEN DECKBOARDS AND BOTTOM OF PICKETS; WEST ELEVATION, REAR PORCH: PORCH IS LEANING EXCESSIVELY, 2X4'S USED AS COLUMNS AT STRINGERS, BEAMS ARE INADEQUATELY CONNECTED TO COLUMNS, 6X6 BEAMS SPAN OVER 7 FEET, 6X6 BEAMS ON 3RD FLOOR ARE ROTTING, UNDERSIZED 2X6 JOISTS SPAN OVER 23 FEET AND ARE SPACED MORE THAN 16 INCHES IB CENTER, STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMNS, NON-UNIFORM RISER HEIGHT, RISER AT 2ND FLOOR IS BROKEN, RAILS ON 2ND FLOOR ARE LOOSE, RAILS ON 3RD FLOOR ARE OF A LADDER DESIGN, PICKETS ARE MISSING AT HANDRAILS, INTERMEDIATE POST IS MISSING AT 1ST FLOOR RAILING SECTION, HOLES IN DECKBOARDS ARE SPACED EXCESSIVELY ON 2ND AND 3RD FLOOR, DECKBOARDS ON 3RD FLOOR ARE BUTTED AND TOENAILED TO FLOOR JOISTS, BIRD FECES ON 3RD FLOOR RAILS, ALL STAIRS ARE LEANING, CEILING/ROOF HATCH IS ROTTING; SUBMIT PLANS AND OBTAIN PERMIT FOR REPLACEMENT | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | WEST ELEVATION: GATE ON PORCH (1ST FLOOR) IS PADLOCKED, PREVENTING REAR EXIT; NORTH: SIDE GATE IS PADLOCKED | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
FLAKY INTERIOR PAINT | NORTH ELEVATION: PEELING PAINT ON 8X8 COLUMN; WEST ELEVATION: PEELING PAINT ON REAR PORCH | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | WEST ELEVATION: LAZY BOY CHAIR ON 2ND FLOOR; CHAIRS AND GARBAGE BAGS ON 3RD FLOOR; NORTH: BROKEN CONCRETE IN YARD | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
NO CLOSET/STORAGE UNDER STAIR | WEST ELEVATION: BIKES, LUMBER, TRASHM CANS, TOYS ARE STORED UNDERNEATH PORCH | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
REPAIR ROOF STRUCTURE | WEST ELEVATION: ROOF HATCH OVER REAR PORCH IS DILAPIDATED AND ROTTING; OBTAIN PERMIT FOR REPAIRS | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
SEND EX. METAL LETTER | SUBMIT ENGINEER REPORT | 2010 S ROCKWELL ST | COMPLAINT | FAILED | View |
PROTECT METAL MEMBERS | SCRAPE PAINT | 2010 S ROCKWELL ST | COMPLAINT | FAILED | View |
F.E. RAILINGS | REPAIR AND REPLACE FIRE ESCAPE RAILING AND PLATFORM | 2010 S ROCKWELL ST | COMPLAINT | FAILED | View |
DEMO DEBRIS | NORTH ELEVATION: BROKEN CONCRETE AND BRICKS IN SIDE YARD | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
REPAIR OR REPLACE | NORTH ELEVATION: DOWNSPOUT IS MISSING (SEC. 18-29-1101.2.1) | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | EAST ELEVATION: BRICKS ON WINDOW SILL AT 2ND FLOOR | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |
FOUNDATION, ADEQUATELY SUPPORT | WEST ELEVATION: FOUNDATION AT BASEMENT HAS BEEN BROKEN UP AND REMOVED; OBTAIN PERMIT FOR REPLACEMENT. SERVICE WALK HAS BEEN REMOVED, ALSO. | 2010 S ROCKWELL ST | COMPLAINT | PASSED | View |