REPAIR EXTERIOR WALL | ABOVE FRONT WINDOW AT 2 MISSING AND LOOSE BRICKS | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH AND SOUTH PARAPETS LOOSE BRICKS FRACTURES AND MISSING MORTAR | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS GRADE TO BASEMENT NO RAIL | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | FRONT PORCH GUTTER AT1 PEELING PAINT | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | REAR DOWNSPOUT RUSTED AND HOLES | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE ROOF ROTTES SHINGLES OVERHEAD DOOR PEELING PAINT | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | ALL AROUND PROPERRTY DEBRIS | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT AND REAR STAIRWAY AT 2 NO SMOKE DETECTOR | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION / EXTERIOR WALL- SECTIONS OF SIDING LOOSE, WITH SOME SECTIONS MISSING. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH, AND SOUTH ELEVATIONS/ PARAPET WALLS- SPALLING BRICKS, WITH WASHED OUT MORTAR. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
CHIMNEY | SOUTH ELEVATION/ CHIMNEY- SPALLING BRICKS, WITH WASHED OUT MORTAR. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
MAINTAIN PROJECTIONS | REAR EXTERIOR DOOR CANOPY- ROTTING, WITH PEELING PAINT. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE ROOF/ SHINGLES- PEELING, AND WORN OUT. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION/ BASEMENT WINDOW VENT- BROKEN PANE. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS, AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS, AND REAR ENCLOSED PORCH. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BUILDING ADDRESS- MISSING. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING/ OWNERS ID SIGN- MISSING. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST SMOKE DETECTOR OUT OF ORDER. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | AT 1ST FRONT AND 2REAR DOORS ALL GLASS- REPLACE. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | ENTRANCE DOOR FRAME MISSING SECTION. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST CARBON MONOXIDE DETECTOR OUT OF ORDER. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR DOOR HARDWARE | INTERIOR DOOR KNOB 1ST MISSING. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REAR SIDING MISSING SECTION. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS MISSING. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 1ST BATHROOM CEILING LARGE HOLES AND LEAKING. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURE (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | AT FRONT VESTIBULE WALL SCONCE | 5135 S SAWYER AVE | COMPLAINT | PASSED | View |
DEFECTIVE OUTLETS | LIVING ROOM | 5135 S SAWYER AVE | COMPLAINT | PASSED | View |
GROUNDING RECEPTACLES | THROUGH OUT 1ST FLOOR UNIT | 5135 S SAWYER AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT AND 2ND FLOOR | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY NO CAP | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST KITCHEN CEILING FULL OF STAIN. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | 1ST OUTLET OUT OF ORDER. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | FOYER AREA HANGING LIGHT FIXTURE AND WIRING. | 5135 S SAWYER AVE | COMPLAINT | FAILED | View |