Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:23 PM
PIN: 20091120180000
Property Address: 729 W 50TH ST
City - Zip: CHICAGO - 60609
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72092
2023 Tax District: 72103
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 9 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR WALL WEST ELEVATION,WASHED OUT MORTAR. 729 W 50TH ST COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH SOUTH ELEVATION,STAIRS GRADE TO BASEMENT,GUARD RAILS,LOOSE AND PULLING. 729 W 50TH ST COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION SOUTH ELEVATION,STONE FOUNDATION WALL,WASHED OUT MORTAR. 729 W 50TH ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM NORTH ELEVATION,FRONT PORCH GRADE TO 1ST FLOOR,4X4 COLUMNS SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN,LEDGER IS FACE NAILED ONLY,JOISTS ARE FACE NAILED ONLY,STRINGERS ARE FACE NAILED ONLY,ROTTED TREADS COVERED WITH CARPET,WEAK AND LOOSE SECTIONS,RAILS ARE LOOSE AND PULLING,32''HIGH,STAIRS HAVE VARYING RISER HEIGHTS OF 6'',7'',8'',DECKING BOARDS ARE WEAK.SOUTH ELEVATION,EXTERIOR PORCHS GRADE TO 2ND FLOOR,6X6 COLUMNS SET ON CONCRETE PIERS ,FOUNDATION STATUS UNKNOWN,COLUMNS ARE OVER NOTCHED,BEAM AT MID-LANDING ARE BOWED,CRACKED,STRINGERS CRACKED,TREADS SPLITTING,LIGHT GAGE METAL,ANGLES,VARYING RISER HEIGHTS OF 4'',7'',7 1/2'',8'',RAILS ARE LOOSE AND PULLING END SUPPORTS ARE MISSING BOLTS,DECKING BOARDS ARE SPLITTING,BEAMS WITH SCABB LUMBER,COLUMNS MISSING AUTO IMPACK POST AT REAR PARKING AREA.PLANS AND PERMIT REQUIRED. 729 W 50TH ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION BUILDING NO ENTRY TO CHECK OCCUPANCY,DETECTORS AND 729-1S ,2ND FLOOR-LOOSE FLOOR TILES,LEAKING ROOF. 729 W 50TH ST COMPLAINT FAILED View
EXPOSED WIRING REMOVE EXPOSE WIRE KITCHEN & FURNACE AREA 729 W 50TH ST COMPLAINT CLOSED View
INSTALL COVERS REPLACE MISSING COVERS ON SWITCHES THRU-OUT 1ST FLOOR REMOVE EXPOSE WIRE KITCHEN & FURNACE AREA 729 W 50TH ST COMPLAINT CLOSED View
REPAIR WINDOW SILLS WEST ELEVATION,STONE WINDOW SILLS,WASHED OUT MORTAR. 729 W 50TH ST COMPLAINT FAILED View
PARAPET WEST ELEVATION,BULGING BRICKS AT CHIMNEY AREA. 729 W 50TH ST COMPLAINT FAILED View