Chicago Building Violations Data: 7 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION FRONT YARD GATE LOCKED, UNABLE TO GET ACCESS TO DOOR TO RING BELL OR KNOCK - NO ENTRY. UNABLE TO VERIFY DETECTORS, CONDITIONS, AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRS. UNABLE TO INSPECT REAR PORCH. 5233 S CARPENTER ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL FRONT ELEVATION /EXTERIOR WALL - 1ST. AND 2ND. FL. - VINYL "J" BEAD - MISSING AROUND WINDOWS; NORTH ELEVATION - MISSING VINYL SIDING; 5233 S CARPENTER ST COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTION REQUIRED 13-32-270 WARM AIR FURNACES * ARRANGE FOR COMPLETE PERMIT INSPECTION WHEN WORK IS COMPLETED 5233 S CARPENTER ST COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT 7040) 18-28-803.9 CHIMNEY CONNECTOR CONSTRUCTION * CHIMNEY CONNECTOR FOR LOW HEAT APPLIANCES SHALL BE MADE OF SHEET METAL PIPE THAT IS RESISTANT CORROSION AND HEAT NO LESS THAN THAT REQUIRED FOR GALVANIZED STEEL AS SPECIFIED FLUES MUST BE PITCHED DOWN TO THE APPLIANCE 5233 S CARPENTER ST COMPLAINT FAILED View
REPAIR OR REPLACE REPAIR OR REPLACE 18-28-911.2.5 * RETURN AIR MUST BE DUCTED OUT SIDE OF MECHANICAL ROOM 5233 S CARPENTER ST COMPLAINT FAILED View
HEAT UNIT ADEQUATELY ROOM TEMPERATURE 59.5 HEATING SYSTEM IS OFF AT TIME OF INSPECTION THERMOSTAT NOT WORKING 5233 S CARPENTER ST COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT 7012) 18-28-801 CHIMNEYS AND VENTS * COMMON VENTING SYSTEM FOR APPLIANCES LOCATED ON MORE THAN ONE FLOOR LEVEL SHALL BE PROHIBITED 5233 S CARPENTER ST COMPLAINT FAILED View