Chicago Building Violations Data: 33 Violations
Violation Inspector Comments Address Category Status View
REPAIR DOOR, INT. COMMON HALLWAY DOOR DOESN'T FASTEN AND MISSING LOCKSET. 6427 S DREXEL AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION ALLOW FOR A FULL INTERIOR INSPECTION OF ENTIRE PROPERTY . NO ENTRY TO UNITS 3N,3S,2S,1N. 6427 S DREXEL AVE COMPLAINT FAILED View
REPAIR LINTELS LINTELS USED AS SUPPORT FOR BALCONIES MISSING MORTAR BUCKLING AND UNSECURED TO BRICK STRUCTURE FOR ALL BALCONIES AT THE FRONT OF PROPERTY WEST ELEVATION. 6427 S DREXEL AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR MISSING HANDRAIL FOR STAIR SYSTEM LOCATED AT THE FRONT OF PROPERTY WEST ELEVATION. 6427 S DREXEL AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL MISSING MORTAR ALL ELEVATIONS EXTERIOR WALLS. 6427 S DREXEL AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH GUARDRAILS FOR BALCONIES LOCATED AT THE FRONT OF PROPERTY UNDER REQUIRED 42" 6427 S DREXEL AVE COMPLAINT FAILED View
REPAIR EXTERIOR PLATFORM CONCRETE PICKETS FOR BALCONIES LOOSE WITH WASHED OUT MORTAR OVER FRONT ENTRANCE DANGEROUS AND HAZARDOUS. 6427 S DREXEL AVE COMPLAINT FAILED View
MICE/RODENTS UNIT 2N MICE INFESTATION. EXTERMINATOR REQUIRED. 6427 S DREXEL AVE COMPLAINT FAILED View
ROACHES UNIT 2N ROACH INFESTATION. EXTERMINATOR NEEDED. 6427 S DREXEL AVE COMPLAINT FAILED View
REPAIR DOOR, INT. UNFINISHED BATHROOM CEILING UNIT 2N. UNIT 1S BATHROOM CEILING WATER DAMAGED. REPAIRS REQUIRED. 6427 S DREXEL AVE COMPLAINT FAILED View
1-HR HEATING PLANT ENCLOSURE FURNACE ROOM LOCATED IN 2N AND 1S SEALED WITH UNAPPROVED FIRE BLOCKING MATERIALS. CURRENTLY COMBUSTIBLE MATERIAL USED TO SEAL PENETRATION (SPRAY FOAM) . REMOVE ALL NON COMBUSTIBLE MATERIAL AND REPLACE WITH FIRE RESISTANT MATERIAL THROUGHOUT PROPERTY. 6427 S DREXEL AVE COMPLAINT FAILED View
FIRE EXTNGSHR REQ, RESDNTL ALL FIRE EXTINGUISHER LOCATED AT THE COMMON AREA HALLWAY SHALL BE PROPERLY TAGGED AND FULLY CHARGED. 6427 S DREXEL AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS UNIT 1S MISSING SMOKE DETECTORS. DANGEROUS AND HAZARDOUS. 6427 S DREXEL AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID UNIT 1S MISSING CARBON MONOXIDE DETECTORS . DANGEROUS AND HAZARDOUS. 6427 S DREXEL AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN ALL NECESSARY PLANS AND PERMIT FOR CORRECTION OF BUILDING CODE VIOLATIONS AND ALL ALTERATIONS PERFORMED THROUGHOUT PROPERTY WITHOUT PROPER PLANS AND PERMITS. 6427 S DREXEL AVE COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL UNAPPROVED CORRUGATED PVC TUBULAR DRAINAGE PIPING AT UNIT 2N BATHROOM LAVATORY.(18-29-702) 6427 S DREXEL AVE COMPLAINT FAILED View
REPLACE DEFECTIVE FAUCET LEAKING LAVATORY FAUCET AT 2N BATHROOM.(18-29-102.3) 6427 S DREXEL AVE COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE CHIPPED WORN TUB AT UNIT 2N BATHROOM. 6427 S DREXEL AVE COMPLAINT FAILED View
OBTAIN PERMIT FOR PLUMBING OBTAIN PERMIT BEFORE CONSTRUCTING , ALTERING OR USING PLUMBING SYSTEM. 6427 S DREXEL AVE COMPLAINT FAILED View
SYSTEM III INSTALL SYSTEM III EM LIGHTS. EXISTING EM LIGHTS NIT COMPLETELY OPERABLE. EXISTING EM LIGHTS NOT BEING MAINTAINED. 6427 S DREXEL AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES INSTALL COVERS FOR FRONT EXTERIOR LIGHT FIXTURE AND REPAIR/REPLACE INOPERABLE LIGHT FIXTURES WHERE REQUIRED THROUGHOUT PREMISES. FLICKERING LIGHT FIXTURES UNIT 2N. 6427 S DREXEL AVE COMPLAINT FAILED View
SECURE RACEWAY SECURE UNSUPPORTED CONDUIT AT UNIT 2N FURNACE ROOM AD WHERE REQUIRED IN TYPICAL UNITS AND SPACES THROUGHOUT PREMISES. THROUGHOUT 6427 S DREXEL AVE COMPLAINT FAILED View
ALL EXTERIOR LIGHT FIXTURES,BOXES,FITTINGS MUST BE SUITABLE FOR WET LOCATION.(14E-1-110.3) 6427 S DREXEL AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS INSTALL APPROVED SHOWER TRIM FOR RECESS LIGHT FIXTURE AT UNIT 2N BATH. 6427 S DREXEL AVE COMPLAINT FAILED View
DOOR ACESS/INTERCOM SYSTEM DOES NOT APPEAR TO BE IN OPERABLE CONDITION. (14E-8-800.24) 6427 S DREXEL AVE COMPLAINT FAILED View
UNAPPROVED CORDS PROVIDE PLANS AND PERMITS TO REPAIR WATER DAMAGED ELECTRICAL SYSTEM AT UNIT 2N BATH, AND WHERE REQUIRED IN TYPICAL UNITS AND SPACES THROUGHOUT PREMISES.(13-12-360) 6427 S DREXEL AVE COMPLAINT FAILED View
UNAPPROVED CORDS PROVIDE PLANS AND PERMITS TO CORRECT VIOLATIONS AND FOR THE INSTALLATION OF ELECTRICAL CONDUITS , BOXES,WIRE,DEVICES AND EQUIPMENT INSTALLED THROUGHOUT UNIT 1N,2N AND WHERE REQUIRED IN TYPICAL UNITS AND AREAS THROUGHOUT PREMISES.FULL GUT REHAB ENTIRE BUILDING INCLUDING NEW SERVICE. PREVIOUS PERMITS INSUFFICIENT. NO INSPECTIONS.(13-12-360) 6427 S DREXEL AVE COMPLAINT FAILED View
UNAPPROVED CORDS PROVIDE ALL REQUIRED ROUGH INSPECTIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT,BOXES,WIRE,DEVICES AND EQUIPMENT INSTALLED THROUGHOUT UNIT 1N.2N AND WHERE REQUIRED IN TYPICAL UNITS AND AREAS THROUGHOUT PREMISES. FULL GUT REHAB ENTIRE BUILDING INCLUDING NEW SERVICE. PREVIOUS PERMITS INSUFFICIENT. NO INSPECTIONS.(13-12-3800 6427 S DREXEL AVE COMPLAINT FAILED View
CONTINUITY OF RACEWAYS ENSURE RACEWAY CONNECTED TO FURNACE AT UNIT 2N FURNACE AND ENSURE GROUND CONTINUITY WHERE REQUIRED THROUGHOUT PREMISES. DANGEROUS AND HAZARDOUS 6427 S DREXEL AVE COMPLAINT FAILED View
WORK NOT ALLOWED REAR OF PROPERTY WOOD PICKET FENCE OVER 5' . REMOVE, REDUCE OR OBTAIN PERMIT TO STAND AS IS. 6427 S DREXEL AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE UNAPPROVED FLEXIBLE WATER SUPPLIES TO BATHROOM TOILETS, LAVATORIES AND KITCHEN SINKS THROUGHOUT PREMISES,(18-29605) 6427 S DREXEL AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING (18-29-106.10 6427 S DREXEL AVE COMPLAINT FAILED View
REMOVE REMOVE ALL COOKING EQUIPMENT FROM REAR OPEN WOOD PORCH EAST ELEVATION CURRENTLY GRILLS HOUSED AND USED ON COMBUSTIBLE MATERIAL (WOOD) PORCH DANGEROUS AND HAZARDOUS.34-13-196-440. 6427 S DREXEL AVE COMPLAINT FAILED View