Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEFECTIVE FEEDER | RESOLVE MIXED CIRCUITS ALL UNITS 18-27-215.2,3,4,5,6, | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR DOOR AT BSMT DOUBLE KEY LOCK | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
LIGHT AND VENT | BSMT GLASS BLOCK PANES THROUGHOUT | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FOYER NO SMOKE DETECTOR | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND PERMIT FOR AUTHORIZE ALTERATIONS TO BSMT OR RESTORE THE BLDG TO THE ORIGINAL STATE | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BSMT REAR CEILING HGHT LESS THAN 7 FEET | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | DOORS NO VIEW DEVICE | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS AT SOUTH ELEVATION. GRADE TO 1ST FLOOR GUARD AND HANDRAILS.HORIZONTIAL DESIGNED. GUARDRAIL AT TOP STEPS NOT BOLTED TO BUILDING AND LESS THAN 42" HIGH.TO RAILS ROTTED 2X4 AND NEWEL POST NOT SECURE TO STRINGERS.PERMIT ONLY FOR REPAIRS AT REAR. | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT STAIR SYSTEM - EAST ELEVATION GUARDRAILS 30"HIGH PICKETS SPACING RANGES 4-8",NO FOOTINGS 2X6 JOISTS HAVE NO HANGERS.LEDGERS NOT BOLTED.PICKETS OUT SIDE GUARD AND HANDRAILS.PERMIT ONLY FOR REPAIRS. | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | SOUTH ELEVATION VENEER PEELING ON DOOR BOTTOM | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | SOUTH ELEVATION LARGE GAP UNDER DOOR- 1ST FLOOR | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | REAR HOLE IN CONCRETE AT STEP | 6112 S WINCHESTER AVE | COMPLAINT | FAILED | View |
DEFECTIVE POWER SERVICE | 6112 S WINCHESTER AVE | PERMIT | FAILED | View | |
SEE INSPECTOR COMMENTS | SEE DEFECT NOTICE | 6112 S WINCHESTER AVE | PERMIT | FAILED | View |