The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PERMIT REQUIRED - CONTRACTOR | 5'-7" IRON SLIDING FENCE BUILT - NO PERMIT OBTAINED. | 5009 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH WOOD FRAME EXTERIOR WALL IS OUT OF PLUMB (INWARD CURVING WALL, BOTTOM TO TOP). PLANS AND PERMIT ARE REQUIRED FOR REPAIRS. | 5009 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | SOUTH GUTTER IS SAGGING. | 5009 S ASHLAND AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR PARKING AREA - JUNK ACCUMULATION. | 5009 S ASHLAND AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | FRONT 2ND FLOOR (2) WINDOWS MADE SMALLER. SOUTH ELEVATION 2ND FLOOR WINDOW MADE SMALLER .PERMIT REQUIRED FOR WINDOW. | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |
CHIMNEY | SOUTH ELEVATION - CHIMNEY WASHED OUT MORTAR. | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |
MAINTAIN EXIT SIGN ILLUMINATED | FRONT 1ST FLOOR STORE FRONT AND REAR EXIT SIGN NOT WORKING AT TIME OF INSPECTION.. | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |
REPAIR LINTELS | FRONT 2ND FLOOR LINTEL (1) LINTEL 6' SAGGING .FRONT 2ND FLOOR LINTEL (5) LINTEL SAGGINGPLANS AND PERMIT REQUIRED FOR REPLACE LINTELS. | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | FRONT 1ST FLOOR WASHED OUT MORTAR.SOUTH ELEVATION 1ST,2ND AND 3RD FLOOR WASHED OUT MORTAR AND STEP CRACKS.SOUTH AND EAST ELEVATION SIDING MISSING.MASON PERMIT REQUIRED FOR ALL MASONARY WORK TO BE DONE. | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |
CHIMNEY | SOUTH ELEVATION - CHIMNEY WASHED OUT MORTAR. | 5009 S ASHLAND AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | SOUTH ELEVATION - CHIMNEY CAP MISSING. | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |
FIRE EXTNGSHR RECHARGE & TAG | FRONT 1ST FLOOR STORE FIRE EXTINGUIHER TAGGED APRIL 2017 | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |
MAINTAIN EXIT SIGN ILLUMINATED | FRONT 1ST FLOOR STORE FRONT AND REAR EXIT SIGN NOT WORKING AT TIME OF INSPECTION.. | 5009 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | 1ST FLOOR STORE REAR EXTERIOR DOOR NO CLOSER. | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | REAR YARD LOOSE PAVERS .REAR YARD GAS TANKS.REAR STAIRS DEBRIS UNDER STAIRS TANKS AND SHEET METAL PARTS. | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS GRADE TO 1ST FLOOR 4X4 COLUMNS ERECTED ON SERVICE WALK FOUNDATION STATUS UNKOWN.LEDGER BOARD NAILED.TREADS ROTTED RISER LOOSE.GUARD RAILS AND STRINGERS NAILED TO COLUMNS,HEADERS AND WALL .GUARD RAILS LOOSE.PICKS MISSING. PERMIT REQUIRED FOR REPAIRS TO REAR PORCH.SOUTH ELEVATION - PORCH GRADE TO 2ND FLOOR 4X6 ERECTED ON DIRT.LEDGER BOARD NAILED TO WALL .GUARD RAILS AND STRINGER NAILED TO COLUMNS ,HEADERS AND WALL.GUARD RAILS LOOSE AND 10' SECTION. RISERS 9" HIGH AND 5" HIGH.PLANS AND PERMIT REQUIRED FOR SOUTH PORCH. | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |
PERMIT REQUIRED - CONTRACTOR | FRONT 2ND FLOOR (2) WINDOWS MADE SMALLER. SOUTH ELEVATION 2ND FLOOR WINDOW MADE SMALLER .PERMIT REQUIRED FOR WINDOW. | 5009 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPAIR COPING | FRONT COPING OPEN MORTAR JOINT. | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |
REPAIR WINDOW SILLS | FRONT 2ND FLOOR OPEN MORTAR JOINT. | 5009 S ASHLAND AVE | COMPLAINT | CLOSED | View |