The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | 1. PORCH HAS OUT LIVED IT'S USEFUL LIFE SPAN.2. WOOD ROTTED THRU-OUT.3. 6X6 COLUMNS RESTING ON CONCRETE AND STONE BLOCKS.4. FOUNDATION STATUS UNKNOWN.5. 6X6 COLUMNS STACKED.6. LOOKOUT BEAMS OVER SPANNED.7. INADEQUATE BEAM TO COLUMN CONNECTION.8. STRINGERS INADEQUATELY SUPPORTED.9. STAIR TREADS TOO SMALL.10. 2X6 JOIST OVER SPANNED.11. PLANS AND PERMIT REQUIRED. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | BUCKLED CONCRETE CAUSING TRIP HAZARD. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS - MISSING SECTIONS OD SIDING THRU-OUT. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 1. 4X4 AND 6X6 COLUMNS RESTING ON CONCRETE BLOCKS SET IN DIRT OR DIRECTLY IN DIRT.2. FOUNDATION STATUS UNKNOWN.3. 2X6 AND 2X8 JOIST OVER SPANNED.4. UNDERSIZED JOIST HANGERS USED THRU-OUT.5. 2X4'S USED AS BEAMS AND RUN BACK INTO BUILDING AT A 45 DEGREE ANGLE.6. STRINGERS INADEQUATELY SUPPORTED.7. STAIR TREADS TOO SMALL.8. GUARDRAILS LOOSE AND WITH PICKETS ON WRONG SIDE.9. PLANS AND PERMIT REQUIRED. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION, HAS WASHED OUT MORTAR. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
PARAPET | EAST PARAPET, HAS WASHED OUT MORTAR. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
REPAIR ROOF | 2ND FLOOR, ROOF LEAKING THRU-OUT. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | COACH HOUSE, NEW PORCH, LEDGER BOARD, MISSING BOLTS, COLUMN TO BEAM CONNECTIONS, MISSING STEEL ANGLES. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | MAIN FRONT HOUSE, REAR PORCH, HAS OVER SPANNED 2X6" JOISTS AND 6X6" BEAMS FOR 10'-0" AND 6'-6" SPAN, CENTER 2ND FLOOR BEAM TO COLUMN CONNECTION IS SCABBED AND SUPPORTED BY STRINGER ONLY, 2ND FLOOR DECK HAS EXCESSIVE PITCH, RAILS ARE TO LOW, 21" AND 32", OTHER COLUMN BEAM CONNECTIONS HAVE A 2" X 4" STEEL ANGLE, PORCH IS IN D&H CONDITION, PLAN AND PERMIT REQUIRED TO REPLACE. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | 2ND FLOOR KITCHEN -BEDROOM CEILING AND FRONT STAIRWAY CEILING AND WALLS HAVE PEELING PAINT AND LOOSE WALL PAPER. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | 2ND FLOOR, BEDROOM FLOOR, MISSING TILES. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR PORCH AND YARD HAS JUNK AND REFUSE ACCUMULATION. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR AND EXTERIOR ALTERATIONS:REMOVED EXISTING ROOF RAFTERS.INSTALLING NEW 2ND FLOOR JOISTS. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 12-080, 13-32-035. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | 2ND FLOOR, KITCHEN, MISSING TILES. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 2ND FLOOR, HAS A VENTLESS GAS SPACE HEATER. | 2828 W FULTON ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | 2ND FLOOR BEDROOM CEILING HAS EXPOSED WIRES. | 2828 W FULTON ST | COMPLAINT | FAILED | View |