Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VENT SYSTEM TO PRVNT BACK PRES | FIXTURE TRAPS MISSING VENTS THROUGHOUT PREMISES. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | FIRE EXTINGUISHERS THROUGH-OUT ARE EXPIRED/ OUTDATED. D&H | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | NORTHWEST ELEVATION REAR EGRESS BLOCKED BY GOODS. D&H | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BASEMENT CEILING 1/4" PLYWOOD USED (COMBUSTIBLE). 1 HOUR FIRE SEPARATION IS REQUIRED. 5/8" TYPE X FIRECODE | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PROVIDE PERMIT FOR INSTALLATION OF DRYWALL. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INSTALLED IN 6033 S KEDZIE (KEDZIE SPA) WITH OUT A PERMIT. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO 6033 S KEDZIE (KEDZIE SPA) OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | THERE ARE SEVERAL TEMP LALLY COLUMNS (SCREW TYPE) INSTALLED AT 1ST FLOOR REAR AND BASEMENT AREAS. TEMP LALLY COLUMNS ARE NOT PERMITTED FOR PERMANENT USE. REPLACE WITH CORRECT TYPE OF COLUMN. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
HEATING PLANT ENCLOSURE | OPEN STUDDING AT FURNACE ROOM 1ST FLOOR REAR AREA. D&H | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
WORKING SPACE | MAIN SERVCIE DISCONNECT AND DISTRIBUTION EQUIPMENT BLOCKED BY DEBRIS, STORAGE AND CLUTTER. DANGEROUS AND HAZARDOUS | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
25-33 OBTAIN PERMIT TO CORRECT VIOLATIONS AND FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRE, DEVICES AND EQUIPMENT. MISCELLANEOUIS ELECTRICAL WORK VARIOUS AREAS. NO PERMITS. PART SOUTH WEST PART OF 25-33 BUILT OUT INTO MASSAGE PARLAR. NO PERMITS. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View | |
DEFECTIVE OUTLETS | 25-33 DAMAGED, CORRODED SWITCHES AND RECEPTACLES VARIOUS AREAS. REPLACE WHERE REQUIRED. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
VENT 5' WITHIN TRAP | UNAPPROVED PVC PIPING USED THROUGHOUT PREMISES. PVC PENETRATIONS THROUGH FLOORS REQUIRING FIRE SEPARATIONS DANGEROUS AND HAZARDOUS. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | 25-33 ADD RECEPTACLES WHERE REQUIRED TO ELIMINATE THE USE OF VISIBLE EXTENSION CORDS. DANGREOUS AND HAZARDOUS | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
25-33 PROVIDE ANY REQUIRED ROUGH INSPECTIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT ,BOXES, WIRE, DEVICES AND EQUIPMENT. MISCELLANSOUS ELECTRICAL WORK THROUGHOUT. NO PERMITS. SOUTH WEST SPACE BUILT OUT INTO MASSAGE PARLOR. NO PERMITS. (14A-5-505.2) | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View | |
CORD TO FIXTURE | 25-33 UNAPPROVED CORD WIRED LIGHT FIXTURES VARIOUS AREAS. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
LISTED FOR USE TEMP & LOCATION | 33 ALL EQUIPMENT USED IN MASSAGE ROOMS MUST BE IDENTIFIED AND SUITABLE FOR USE INCLUDING TABLES, TUBS, LAMPS, ETC. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | OPEN BOXES VARIOUS. CLOSE WHERE REQUIRED. DANGEROUS AND HAZARDOUS | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | 25-33 SERVICE HEAD COMPLETELY DAMAGED. OVERHEAD SERVICE CABLES APPEAR DAMAGED AT HEAD. C/T CABINET HAS LARGE OPENING IN SIDE. MAIN DISCONNECT DETERIORATED / DAMAGED WITH EXPOSED LIVE PARTS. ASSOCIATED DISTRIBUTION DETERIORATED LIVE FRONT. SERVICE MODIFIED FROM ORIGINAL CONDITION NO PERMITS. ENSURE SERVICE IN APPROVED CONDITION. DANGEROUS AND HAZARDOUS | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | 25-33 DAMAGED, UNCOVRED LIGHT FIXTURES VARIOUS. REPAIR REPLACE WHERE REQUIRED. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | 25-33 INSUFFICIENTLY SUPPORTED LIGHT FIXTURES VARIOUS AREAS THROUGHOUT. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
SUBMIT PLANS FOR PLUMBING PRMT | SUBMIT PLANS TO BUILDING, WATER AND SEWER DEPARTMENTS FOR APPROVAL AND PERMIT BEFORE CONSTRUCTING, ALTERING OR USING PLUMBING SYSTEM. SPECIFICALLY ENTIRE PLUMBING SYSTEM HAS BEEN MODIFIED FROM ORIGINAL STATE WITHOUT PLANS PERMITS OR INSPECTIONS. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
INDIRECT CONN.FOR WATER SUPPLY | WATER SUPPLIES TO SHOWERING TABLE WANDS AT 6033 FRONT UNIT USED AS SPA ARE DIRECTLY CONNECTED TO POTABLE WATER SYSTEM WITHOUT ANY MEANS OF CROSS CONTAMINATION PREVENTION. DANGEROUS AND HAZARDOUS. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | 25-33 OPEN WIRING VARIOUS AEAS INTERIOR AND EXTERIOR. REMOVE WHERE REQUIRED. DANGEROUS AND HAZARDOUS | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
33 OBTAIN PERMIT TO CORRECT VIOLATIONS AND FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRE, DEVICES AND EQUIPMENT. SPACE WITHIN 25-33 BUILT OUT INTO MASSAGE PARLOR. NO PERMITS. (14A-4-404.6) | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View | |
SECURE RACEWAY | 25-33 UNAUPPORTED CONDUITS VARIOUS AREAS. SECURE WHERE REQUIRED. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
LISTED FOR USE TEMP & LOCATION | 25-33 ALL EXTERIOR LIGHT FIXTURES, BOXES, FITTINGS, RACEWAYS MUST BE SUITABLE FOR WET LOCATION. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
PROPER SIZE GRD ELECTRODE COND | 25-33 NO VISIBLE WATER GROUND. ENSURE SERVICE GROUNDE IN APPROVED MANNER. DANGEROUS AND HAZARDOUS | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
PANEL SCHEDULES | 25-33 INSUFFICIENT PANEL SCHEDULES THROUGHOUT. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View | |
SEE INSPECTOR COMMENTS | 25-33 PROVIDE ONE LINE DIAGRAM AND LOAD CALCULATION FOR ELECTRICAL SERVICE AND FEEDERS. (14E-2-215.5, 14E-2-220.40) | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | SUMP PIT MISSING COVER AT BASEMENT. DANGEROUS AND HAZARDOUS. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | 25-33 EXISTING EMERGENCY LIGHTING SYSTEM IS UNAPPROVED, INOPERABLE, UNMAINTAINED, INSUFFICIENT. DANGEROUS AND HAZARDOUS | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
33 PROVDE ALL REQUIRED ROUGH INSPECTIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRE, DEVICES AND EQUIPMENT. SPACE WITHING 25-33 BUILT OUT INTO MASSAGE PARLOR. NO PERMITS. (14-5-505.2) | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View | |
PROVIDE OPEN FRONT TOILET SEAT | UNAPPROVED ROUND BOWL TOILET WITH CLOSED FRONT SEAT. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | 25-33 INSTALL ILLUMINATION AT ALL EXTERIOR ENTRIES AND WHERE REQUIRED THROUGHOUT. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
CLOSE BOX OPENINGS | 25-33 MISSING BOX FILLERS, PANEL FILLERS THROUGHOUT. DANGEROUS AND HAZARDOUS | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
PROVIDE ADEQUATE SUPPORT | INSUFFICIENT HANGER SUPPORT TO SUSPENDED CAST IRON PIPING AT BASEMENT. PIPING IS SUPPORTED USING BAND IRON AND DRYWALL SCREWS. SECTIONS OF PIPING HAVE BEEN REPLACED WITH PVC DUE TO COLLAPSING PREVIOUSLY PER OWNER. SUSPENDED CAST IRON SYSTEM IS SHOWING SIGNS OF FAILURE DUE TO LACK OF SUPPORT. DANGEROUS AND HAZARDOUS. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
INSTALL GFCI'S | 25-33 INSTALL GFCI RECEPTACLES BATH, KITCHEN AREAS, INDOOR WET LOCATIONS, GARAGE, EXTERIOR.SINKS | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | 25-33 DAMAGED PANELS. PANELS WITH BROKEN / MISSING COVERS. PANELS WITH MISSING CIRCUIT BREAKERS. DETERIATED BROKEN DISCONNECTS AND FUSE BOXES. ENSURE DISTRIBUTION THROUGHOUT PREMISES IN APPROVED CONDITION. DANGEROUS AND HAZARDOUS | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
25-33 PROVIDE FULL ACCESS TO INSPECT DROP CEILING AREAS THROUGHOUT PREMISES. (14E-5-505.2) | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View | |
PROVIDE | MISSING MIXING VALVES AT LAVATORIES THROUGHOUT. (18-29-607) | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | MISSING DIE-ELECTRICAL CONNECTIONS WHERE COPPER CONNECTS TO GALVANIZED PIPING THROUGHOUT PREMISES. | 6027 S KEDZIE AVE | COMPLAINT | FAILED | View |