Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SERVICE WALK, PASSAGE, AREAWAY | 07-00003034 WEST ELEVATION, BROKEN SERVICE WALK. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1ST FLOOR NORTH AND 2ND FLOOR SOUTH BROKEN WINDOW PANES. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | ALL ELEVATIONS AND LEVELS, WINDOWS WITH FLAKING PAINT. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | ALL ELEVATIONS AND LEVELS, WINDOWS MISSING PUTTY. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER/MANAGEMENT INFO NOT POSTED. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | GARAGE OVERHEAD DOOR MISSING SECTION, SAGGING LINTEL, JOIST BOWED, EAST ELEVATION ROTTED WOOD TRIM. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
SCAVENGER SERVICE | JUNK AND DEBRIS IN GARAGE. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | REAR YARD REMOVE HIGH WEEDS CUTTINGS. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | SUBMIT ENGINEER REPORT FOR RECENT REPAIRS TO PORCH. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQUIRED | BASEMENT BEING USED AS SLEEPING ROOM. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCH, 4X4 COLUMN NOT RESTING ON FOUNDATION (3/4 OF 4X4 COLUMN OF FOUNDATION, LEDGERS MISSING BOLTS, SCABBED WOOD IN JOIST HANGERS, OPEN BEAM POCKETS AT 2ND LEVEL, INADEQUATE BEAM-COLUMN CONNECTIONS/MISSING BOLTS, 6X6 COLUMN ROTTED FULL LENGTH, COLUMN SPLICE CONNECTIONS MISSING BOLTS, IMPROPER GUARDRAIL HEIGHT, SCABBED WOOD AT GUARDRAIL CONNECTIONS, STAIRS WITH VARYING RISER HEIGHT AT GROUND LEVEL, SPIRAL CONNECTIONS TOE NAILED, SPIRAL STAIR TREAD DEPTH INADEQUATE, DECKING ROTTED, LOOSE HAND AND GUARDRAILS THRU-OUT. OBTAIN PLANS AND PERMITS FOR PORCH RE-BUILD OR REPLACEMENT. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
FOUNDATION, ADEQUATELY SUPPORT | REAR PORCH MISSING FOOTINGS. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | FRONT GATE OFF HINGES CREATING TRIP HAZARD. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
NO EXIT FROM BUILDING AT GRADE | FRONT GATE AND NORTH SIDE SERVICE WALK BLOCKED BY TRASH CONTAINERS. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | REAR- SHEATHING LOOSE. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | FRONT AREAWAY WALL- SHIFTING BRICKS, AND OPEN MORTAR JOINTS. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH- 6X6 COLUMN BOWED, ERECTED ON SIDE WALK. 2ND FLOOR / NO LEDGER BOLTS AT EXTERIOR WALL. OLD WOOD LAMINATED TO ROTTED WOOD AT ROOF JOIST, ONLY 1 BOLT AT SCAB CONNECTION. DRYWALL SCREW USED ON BEAM TO COLUMN CONNECTIONS. . GAP AT ROOF BEAMS TO COLUMN CONNECTION. PERMIT AND PLANS REUIRED FOR REPAIRS. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR DOOR - PEELING VENEER. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK PITCHED TOWARD GARAGE. DAMAGED CONCRETE. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE- OVER HEAD DOOR OFF TRACK.SERVICE DOOR MISSING WOOD PANEL SECTION. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | SASHES - ROTTED. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR DOOR FRAME, MULLION | FRONT DOOR- GAP AROUND LOCK. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | MISSING SCREENS. SOME SCREEN INSERTS TO SMALL FOR OPENING. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
INSECTS | 2ND FLOOR APT.-INSECT AND SPIDERS . | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | OVERGROWN TREE / 4-5 STORTY TREE , TRUNK BASE AS WIDE AS A SMALL VEHICLE, TREE LIMBS LEANING AGAINST GARAGE ROOF, BLOCKING REAR GATE AT ALLEY. TREE CLIPPING STACKED 4 FEET HIGH IN ALLEY. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR COPING | SOUTH MISSING COPING STONE. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
PARAPET | SOUTH PARAPET LOOSE BRICKS, PERMIT REQUIRE FOR REPAIR. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY WASHED OUT MORTAR. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT WING WALL LOOSE BRICKS. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WORN SASHES. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1ST NORTH BROKEN WINDOW PANE. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | ALL ELEVATION FALLING AND LOOSE PUTTY. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT GATE BLOCK WITH GARBAGE CAN, REAR CHAIN AND PADLOCK. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILD-NO ENTRY, UNABLE TO VERIFY DETECTOR AND CONDITION. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY WASHED OUT MORTAR. | 8119 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED. | 8119 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | FRONT WING WALL LOOSE BRICKS. | 8119 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW SASH | WORN SASHES. | 8119 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT GATE BLOCK WITH GARBAGE CAN, REAR CHAIN AND PADLOCK. | 8119 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
DEFECTIVE FIXTURES | FRONT HALL 1ST FLOOR LIGHT FIXTURE MISSING. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 1ST AND 2ND FLOOR DOORS MISSING VIEWING DEVICES. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES- ROTTED. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR COPING | SOUTH MISSING COPING STONE. | 8119 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
PARAPET | SOUTH PARAPET LOOSE BRICKS, PERMIT REQUIRE FOR REPAIR. | 8119 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1ST NORTH BROKEN WINDOW PANE. | 8119 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
REPUTTY WINDOW PANES | ALL ELEVATION FALLING AND LOOSE PUTTY. | 8119 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILD-NO ENTRY, UNABLE TO VERIFY DETECTOR AND CONDITION. | 8119 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR GATE PADLOCKED. | 8119 S HERMITAGE AVE | COMPLAINT | FAILED | View |