Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEAT UNIT ADEQUATELY | APT. 1 / ROOM TEMPERATURES: BEDROOM TEMP. 63F, LIVING ROOM TEMP. 64F. AT 12:55PM.HEATING SYSTEM IS ON AT TIME OF INSPECTION, HEAT IS INSUFFICIENT. | 3832 W FULTON ST | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | FRONT ENTRY DOOR AND APT. - 1 ENTRY DOOR / UP TO HALF INCH GAPS ALL AROUND DOORS, DRAFTY WITH AIR SEEPAGE. | 3832 W FULTON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION / EXTERIOR WALL / SECOND FLOOR - FRACTURES MASONRY WITH WASHED OUT MORTAR. | 3832 W FULTON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | BUILDING'S FRONT ENTRY DOOR - FRAME WITH UP TO HALF INCH GAPS.DRAFTY, AIR SEEPAGE. | 3832 W FULTON ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | APT. - 1 / DINING ROOM WALL - CRACKED, MISSING PLASTER WITH A 4 INCH HOLE.KITCHEN / SOUTH WALL / CEILING - BUBBLING PLASTER BETWEEN CEILING AND WALL. | 3832 W FULTON ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 2 STORY ENCLOSED PORCH / CONCRETE PILLARS UNDER 6X6 COLUMNS LEANING OUT OF PLUMB. EAST ELEVATION / FOUNDATION WALL - CRACKED, LEANING OUT OF PLUMB WITH SPALLED AND CRACKED CONCRETE. EASTERN 6X6 COLUMN ROTTED. EASTERN 4X6 BEAM TO COLUMN CONNECTION PULLING OUT OF FIRE CUT WITH . SECOND FLOOR 6X6 COLUMNS STACKED ON TOP OF 4X6 BEAMS. 4X6 BEAMS SPAN 6 FOOT. UPPER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS, FASTENED WITH NAILS ONLY. FIRST AND SECOND FLOOR DECKS SAGGING UP TO 2 INCHES. HOUSEHOLD ITEMS BEING STORED ON FIRST TO SECOND FLOOR LANDING INCLUDE GABAGE CANS, BICYCLES JUNK.PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 3832 W FULTON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF APARTMENT 2, BASEMENT AND FRONT INTERIOR STAIRWAY - NO RESPONSE UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. | 3832 W FULTON ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | APT. - 1 / KITCHEN FLOOR - SAGGING | 3832 W FULTON ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | JUNK, DEBRIS, SHOES | 3832 W FULTON ST | COMPLAINT | CLOSED | View |
PARAPET | PARAPET WALL - WASHED OUT MORTAR; LOOSE BRICKS | 3832 W FULTON ST | COMPLAINT | CLOSED | View |