Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 4:35 PM
PIN: 16113030110000
Property Address: 3832 W FULTON ST
City - Zip: CHICAGO - 60624
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77102
2023 Tax District: 77052
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 10 Violations
Violation Inspector Comments Address Category Status View
HEAT UNIT ADEQUATELY APT. 1 / ROOM TEMPERATURES: BEDROOM TEMP. 63F, LIVING ROOM TEMP. 64F. AT 12:55PM.HEATING SYSTEM IS ON AT TIME OF INSPECTION, HEAT IS INSUFFICIENT. 3832 W FULTON ST COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE FRONT ENTRY DOOR AND APT. - 1 ENTRY DOOR / UP TO HALF INCH GAPS ALL AROUND DOORS, DRAFTY WITH AIR SEEPAGE. 3832 W FULTON ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL WEST ELEVATION / EXTERIOR WALL / SECOND FLOOR - FRACTURES MASONRY WITH WASHED OUT MORTAR. 3832 W FULTON ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR, RESET BUILDING'S FRONT ENTRY DOOR - FRAME WITH UP TO HALF INCH GAPS.DRAFTY, AIR SEEPAGE. 3832 W FULTON ST COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING APT. - 1 / DINING ROOM WALL - CRACKED, MISSING PLASTER WITH A 4 INCH HOLE.KITCHEN / SOUTH WALL / CEILING - BUBBLING PLASTER BETWEEN CEILING AND WALL. 3832 W FULTON ST COMPLAINT FAILED View
REPLACE D&H PORCH REAR 2 STORY ENCLOSED PORCH / CONCRETE PILLARS UNDER 6X6 COLUMNS LEANING OUT OF PLUMB. EAST ELEVATION / FOUNDATION WALL - CRACKED, LEANING OUT OF PLUMB WITH SPALLED AND CRACKED CONCRETE. EASTERN 6X6 COLUMN ROTTED. EASTERN 4X6 BEAM TO COLUMN CONNECTION PULLING OUT OF FIRE CUT WITH . SECOND FLOOR 6X6 COLUMNS STACKED ON TOP OF 4X6 BEAMS. 4X6 BEAMS SPAN 6 FOOT. UPPER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS, FASTENED WITH NAILS ONLY. FIRST AND SECOND FLOOR DECKS SAGGING UP TO 2 INCHES. HOUSEHOLD ITEMS BEING STORED ON FIRST TO SECOND FLOOR LANDING INCLUDE GABAGE CANS, BICYCLES JUNK.PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. SUBJECT TO FIELD INSPECTION AND APPROVAL. 3832 W FULTON ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF APARTMENT 2, BASEMENT AND FRONT INTERIOR STAIRWAY - NO RESPONSE UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. 3832 W FULTON ST COMPLAINT FAILED View
REPAIR FLOOR APT. - 1 / KITCHEN FLOOR - SAGGING 3832 W FULTON ST COMPLAINT FAILED View
STOP/REMOVE NUISANCE JUNK, DEBRIS, SHOES 3832 W FULTON ST COMPLAINT CLOSED View
PARAPET PARAPET WALL - WASHED OUT MORTAR; LOOSE BRICKS 3832 W FULTON ST COMPLAINT CLOSED View