The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MAINTAIN WINDOW | REAR BUILDING , ALL ELEVATIONS - ROTTED WINDOW FRAMES.FRONT BUILDING ,EAST ELEVATION - ROTTED ATTIC WINDOW FRAME. | 8549 S MUSKEGON AVE | COMPLAINT | FAILED | View |
CHIMNEY | REAR BUILDING,CHIMNEY - FRACTURES ,LOOSE BRICKS AND MORTAR. PERMIT FOR REPAIRS/REPLACE REQUIRED. | 8549 S MUSKEGON AVE | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | FRONT BUILDING,NORTH AND SOUTH ELEVATIONS - MISSING GUTTERS AND DOWNSPOUTS. | 8549 S MUSKEGON AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | FRONT BUILDING REAR PORCHES - OVERNOTCHED COLUMNS, UNDERSIZED JOISTS, ROTTED DECK BOARDS ,GAURD RAILS AND JOISTS, 33" GAURDRAIL HIEGHTS.REAR BUILDING FRONT PORCH - UNDERSIZED JOISTS,MISSING JOIST HANGERS, LOOSE HANDRAILS, 32" GAURDRAIL HEIGHT.BOTH FRONT AND REAR BUILDING PORCH SYSTEMS FASTENED BY ONLY NAILS.PLANS AND PERMITS ARE REQUIRED FOR REPAIRS/REBUILDS. ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL. | 8549 S MUSKEGON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REAR BUILDING,ALL ELEVATIONS - FRACTURES, ERODED MORTAR AT VARIOUS LOCATIONS.FRONT BUILDING EAST ELEVATION - LOOSE, WARPED AND MISSING SIDING PANELS. | 8549 S MUSKEGON AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR BUILDING, ALL ELEVATIONS -BROKEN WINDOWS | 8549 S MUSKEGON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | COACH HOUSE WEST 1-STORY OPEN WOOD PORCH -(1) ALL WOOD IN VARIOUS STAGES OF ROTT WITH MANY MEMBERS WARPED, SPLIT AND/OR BROKEN(2) EXPOSED NAILS ARE RUSTED AND PULLING CREATING LARGE GAPS AND WEAK JOINTS(3) JOIST, RIM-JOIST, LEDGERS, STRINGERS, POST, COLUMNS AND RAILINGS HAVE WEAK CONNECTIONS AND ARE ONLY FACE NAILED OR TOE NAILED(4) COLUMNS BEAR ON CONCRETE BLOCKS WITH UNKNOWN FOUNDATIONS(5) STAIR HANDRAILS ARE WEAK AND MOVES WHEN GRABBED(6) PERMIT REQUIRED FOR REPAIRS | 8549 S MUSKEGON AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | IMMINENTLY DANGEROUS AND HAZARDOUS REAR 2-STORY PARTIALLY OPEN WOOD PORCH WITH ROOF AND BASEMENT ACCESS -(1) SOUTH OPEN DECKS - WOOD IS SEVERELY ROTTED WITH MANY MEMBERS WARPED, SPLIT AND/OR BROKEN(2) EXPOSED NAILS ARE RUSTED AND PULLING CREATING LARGE GAPS AND WEAK JOINTS(3) JOIST AND RIM-JOIST CONNECTIONS ARE ONLY FACE NAILED OR TOE NAILED(4) COLUMNS BEAR ON CONCRETE BLOCKS WITH UNKNOWN FOUNDATIONS(5) DECK AND ROOF JOIST ARE UNDERSIZED, OVER SPANNED AND SAGGING(6) BEAM-TO-COLUMN CONNECTIONS ARE SUBSTANTIALLY ROTTED AWAY AND WEAK WITH WEAK THIN METAL STRAP ANCHORS AND MUCH OF THE WOOD MISSING(7) COLUMN SPLICES ARE ONLY TOE NAILED WEAK STACK JOINTS(8) DECK GUARDRAILS ARE ROTTED, WEAK, OVERSPANNED AND SAGGING(9) NORTH HALF OF STRUCTURE - ENCLOSED WITH NO DRAWINGS OR PERMITS ON FILE(10) DRAWINGS ARE REQUIRED TO OBTAIN THE REPLACEMENT PERMIT | 8549 S MUSKEGON AVE | COMPLAINT | FAILED | View |