Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ROACHES | BUILDING - ROACHES THROUGHOUT. ROACH INFESTATION OBSERVED AT 2ND FLOOR UNIT AT HALLWAY AND KITCHEN. | 6840 S UNION AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRS - HAND RAILING LOOSE AND PULLING AWAY FROM WALL. | 6840 S UNION AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR OF BUILDING/AT REAR PORCH - WATER SPIGOT PROTUDES OUT AND INTERFERES WITH DIRECTION OF TRAVEL, OBSTRUCTS PATH OF EGRESS. | 6840 S UNION AVE | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | REAR ENCLOSED PORCH / SQUIRRELS OBSERVED - NESTING IN ENCLOSED PORCH CEILING. | 6840 S UNION AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | REAR ENCLOSED PORCH CEILING - HOLES FROM SQUIRRELS EATING THROUGH DRYWALL. REAR INTERIOR STAIRWAY CEILING - WATER DAMAGE AND UNFINISHED DRYWALL REPAIRS. | 6840 S UNION AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT APARTMENT CEILING HEIGHT ONLY 6 FEET 9 INCHES. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
CORRIDOR ENCLOSURE - BASEMENT | BASEMENT APARTMENT FRONT ENTRANCE IS THROUGH UNENCLOSED HEATING PLANT. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF 1ST FLOOR AND BASEMENT - NO RESPOPNSE, UNVERIIFED DETECTORS, CONDITIONS AND OCCUPANCY. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT ONE STORY PORCH/ HAND RAILING LOOSE, OVERSPANNED AND MISSING INTERMEDIATE SUPPORT POST; GUARDRAILS UNDERSIZED ONLY 2 FEET HIGH. REAR ONE STORY PORCH ATTACHED TO ENCLOSURE/ 4X4 COLUMNS ERECTED ON TOP OF CONCRETE SLAB; COLUMNS AND BEAM CONNECTIONS NOTCHED AND NAILED ONLY; TOP GUARD RAIL BROKEN, LOOSE AND PULLING AWAY; STAIR HANDRAIL OVERSPANNED AND MISSING INTERMEDIATE SUPPORT POST; UPPER ENDS OF STINGERS TOE NAILED INTO POSTS; STAIR STRINGER SPLIT, CRACKED AND BROKEN; STAIR TREADS LOOSE, CRACKED AND BROKEN; DECKING WORN-OUT, LOOSE, AND BUCKLED. OBTAIN PERMIT TO REPLACE REAR ONE STORY PORCH. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
REPAIR DOOR, INT. | 2ND FLOOR APARTMENT/ FRONT ENTRY DOOR - DOOR OFF HINGES AND RUBS AGAINST CARPET; DOOR BROKEN AND GOUGED OUT NEAR BOTTOM HINGE. REPLACE FRONT DOOR. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWELL - MISSING SMOKE DETECTOR. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
REPAIR FLOOR | 2ND FLOOR APARTMENT/ LIVING ROOM FLOOR - HOLE ON FLOOR; MISSING VENT COVER. KITCHEN FLOOR - TILES CURLED, CRACKED, BROKEN AND MISSING. BATHROOM FLOOR - TILES SHIFTED, LOOSE AND MISSING. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
RESET LOOSE FIXTURE | 2ND FLOOR APARTMENT/ BATHROOM - TUB UNLEVELED, APPEARS TO BE SINKING TO ONE SIDE. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
COVER OUTLETS AND JBS | 2ND FLOOR APARTMENT/ BEDROOM AND LIVING ROOM - SOME OUTLET COVERS MISSING. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | 2ND FLOOR APARTMENT/ BEDROOM WINDOW - LOOSE AND BROKEN SASH, DUCTED TAPED IN PLACE; INOPERABLE WINDOW. REPLACE BROKEN WINDOW. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
UNAPPROVED HEATING DEVICE | 2ND FLOOR APARTMENT - USING ELECTRIC SPACE HEATERS TO HEAT UP APARTMENT. HEAT IS ON AT TIME OF INSPECTION. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | BASEMENT APARTMENT AND FURNACE ROOM MISSING SMOKE DETECTORS. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | BASEMENT ALTERED INTO A DWELLING UNIT WITH FULL KITCHEN,BEDROOM,LIVING ROOM AND BATHROOM WITHOUT A PERMIT.REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING ELECTRIC AND PLUMBING) INSTALLED WITHOUT PERMIT. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | BASEMENT APARTMENT AND FURNACE ROOM MISSING CARBON MONOXIDE DETECTORS. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | 2ND FLOOR / SOME BEDROOM AND LIVING ROOM WINDOWS - ROTTING WOOD AND COVERED WITH PLASTIC. WINDOWS ARE DRAFTY WITH AIR FILTRATION. EAST ELEVATION / 2ND FLOOR WINDOW FRAME - ROTTING WOOD. SCREENS - TORN THROUGHOUT. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
UNSANITARY CONDITIONS-ANIMALS | REAR ENCLOSED PORCH / SQUIRRELS OBSERVED - NESTING IN ENCLOSED PORCH ROOF. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | ELLREAR ENCLOSED PORCH - HOLES FROM SQUIRRELS EATING THROUGH DRYWALL. REAR INTERIOR STAIRWAY - WATER DAMAGE AND UNFINISHED DRYWALL REPAIRS. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
ROACHES | BUILDING - ROACHES THROUGHOUT. ROACH NFESTAION OBSERVED AT 2ND FLOOR UNIT AT HALLWAY AND KITCHEN. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT TO AUTHORIZE ALL ALTERATIONS TO THE BASEMENT OR RESTORE THE BUILDING TO ITS ORIGINAL CONDITIONS. | 6840 S UNION AVE | COMPLAINT | PASSED | View |
1HR SEP-D.U. AND REST OF BLDG | BASEMENT APARTMENT PARTITION WALL SEPARATING FURNACE ROOM AND LIVING ROOM HAS ONLY DRYWALL ON ONE SIDE OF THE STUD. | 6840 S UNION AVE | COMPLAINT | PASSED | View |