REPAIR EXTERIOR STAIR | REAR GRADE TO BASEMENT-PROVIDE HANDRAIL | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR FENCE | REPAIR CHAIN FENCE LEAVING OVER WALK IN REAR, TOP RAIL MISSING | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR STOOP | NORTH ELEVATION 2003-REPAIR CRACKED STOOP AT ENTRANCE | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR AREAWAY WALL | REPAIR AREA WALLS AT WEST AND 2001 ENTRANCE-CRACKER SURFACE | 2001 E 75TH ST | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR GATE KEY LOCK | 2001 E 75TH ST | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT STAIRS NO GUARD RAIL | 2001 E 75TH ST | PERIODIC | FAILED | View |
CHIMNEY CAPPING | CHIMNEY NO CAP. | 2001 E 75TH ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR 2ND AND 3RD NO ENTRY | 2001 E 75TH ST | PERIODIC | FAILED | View |
LOOSE PLATE GLASS | 2001 1ST BROKEN PLATE GLASS | 2001 E 75TH ST | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR GATE KEY LOCK | 2001 E 75TH ST | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT STAIRS NO GUARD RAIL | 2001 E 75TH ST | PERIODIC | FAILED | View |
CHIMNEY CAPPING | CHIMNEY NO CAP. | 2001 E 75TH ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR 2ND AND 3RD NO ENTRY AND ABLE TO INSPECT REAR PORCHES PROPERLY GATE LOCKED. NEWLY BUILT PORCHES ONLY VISIBLE THROUGH REAR GATE. | 2001 E 75TH ST | PERIODIC | FAILED | View |
LOOSE PLATE GLASS | 2001 1ST BROKEN PLATE GLASS | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | REPAIR EXTERIOR WALL - (1) SOUTHWEST CORNER SEVERE STONE MOVEMENT STONE, BRICK HAS SHIFTED (2) WEST ELEVATION PARAPET WALL SEVERE WASHED OUT MORTAR (3) NORTHWEST CORNER SEVERE BRICK AND STONE DISPLACEMENT STONE HAS SHIFTED AT CORNER OF BUILDING (4) WEST ELEVATION BRICK STRESS CRACKS, BRICK DISPLACED AT SECOND FLOOR CENTER OF BUILDING (5) PLANS AND PERMITS FOR ALL REPAIRS (6) LINTELS AND SHELF ANGELS IN WALL RUSTED CAUSING LARGE JOINTS AT NORTHEAST CORNER WIDE GAPS | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | WALLS (1) STAIRWELL SEVERLY DAMAGED MISSING LARGE PIECE OF DRYWALL (2) UNIT 3A BATHROOM WALL IN SHOWER/TUBE AREA SEVERLY DAMAGED CAN SEE INTO STAIRWELL AREA | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | STAIRS IN 1509 ENTRANCE TREADS WEAK AT 1ST LEVEL TO SECOND LEVEL AND BOWING AT INTERMEDIATE TURN LEVEL | 2001 E 75TH ST | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS FOR PORCHES BUILT | 2001 E 75TH ST | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR GATE - KEY LOCK | 2001 E 75TH ST | PERIODIC | FAILED | View |
CHIMNEY CAPPING | EAST CHIMNEY - CAPPING MISSING. | 2001 E 75TH ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | 2ND AND 3RD FLOOR: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. UNABLE TO INSPECT REAR PORCHES AND OTHER COMPLAINTS IN 7503 S. / APT. 4C. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTHWEST AND NORTHWEST CORNERS - BRICKS AND STONES SHIFTING. WEST ELEVATION BRICK STRESS CRACKS AND DISPLACEMENT. PERMIT REQUIRED FOR REPAIRS. | 2001 E 75TH ST | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS REQUIRED FOR REAR PORCHES BUILT WITHOUT A PERMIT - PORCHES VISIBLE FROM ALLEY WAY. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | ALL ELEVATIONS - WINDOW SILLS - BROKEN, SHIFTED, OPEN JOINTS AND MISSING MORTAR. | 2001 E 75TH ST | PERIODIC | FAILED | View |
PARAPET & COPING | NORTH AND WEST ELEVATIONS - PARAPET WALLS AND COPINGS - OPEN JOINTS AND WASHED OUT MORTAR. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST AT 2 - WINDOW PANE - BROKEN. | 2001 E 75TH ST | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | 7505 S. / STORE FRONT - FIRE EXTINGUISHER - EXPIRED TAG. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 7503 S. AND 7505 S / STORE FRONT - CEILINGS - WATER DAMAGE. | 2001 E 75TH ST | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | 7503 S. / STORE FRONT - FRONT AND REAR EXIT SIGNS - OUT OF SERVICE, NOT ILLUMINATED. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR FLOOR | 7503 S. / STORE FRONT - FLOOR TILES - LOOSE, BROKEN AND MISSING SECTIONS. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR LINTELS | NORTH AND WEST ELEVATIONS - LINTELS - RUSTING, WITH LARGE JOINTS AND GAP AT NORTHEAST CORNER. PERMIT REQUIRED FOR LINTEL REPLACEMENT. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR LINTELS | NORTH AND WEST ELEVATION LINTELS - RUSTING AND DEFLECTING, WITH LARGE JOINTS AND GAP AT NORTHEAST CORNER. MASONRY PERMIT REQUIRED FOR LINTEL REPLACEMENT. NOTE: LINTELS HAVE BEEN COVERED WITH LARGE METAL WRAP, REMOVE METAL WRAP, LINTELS NEED REPLACEMENT, NOTICEABLE STEP FRACTURES AND BULGING BRICKS WITH WASHED OUT MORTAR AT LINTELS. | 2001 E 75TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS, UNABLE TO VERIFY COMPLAINT OF MOLD, NO ACCESS TO INSPECT REAR PORCHES. | 2001 E 75TH ST | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR PORCHES CONSTRUCTED WITH OUT SUBMITTING PLANS AND OBTAINING PERMIT. | 2001 E 75TH ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED FROM 2006 THROUGH 2015. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR LINTELS | NORTHWEST CORNER OF BUILDING - CANTILEVERED STEEL BEAMS ARE RUSTED AND DEFLECTING. | 2001 E 75TH ST | PERIODIC | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | SUBMIT 2 COPYS OF STRUCTURAL ENGINEERS REPORT FOR EXTERIOR WALLS. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR COPING | NORTH AND WEST ELEVATIONS COPING - WASHED OUT MORTAR. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION BASEMENT WINDOWS - BROKEN GLASS BLOCKS. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR BASEMENT EXTERIOR STAIRS - MISSING HANDRAIL. | 2001 E 75TH ST | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY - WASHED OUT MORTAR. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | NORTH AND WEST WINDOW SILLS - WASHED OUT MORTAR. | 2001 E 75TH ST | PERIODIC | FAILED | View |
PARAPET & COPING | NORTH SOUTH WEST ELEVATIONS - PARAPET WALLS AND COPINGS - OPEN JOINTS AND WASHED OUT MORTAR. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR CORNICE | NORTH AND WEST ELEVATIONS - CORNICE - OPEN JOINTS AND WASHED OUT MORTAR.NORTHWEST AND SOUTHWEST COPING STONES - SHIFTING OUT. MASONRY PERMIT REQUIRED FOR EXTERIOR WALLS REPAIRS. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST AT 2 - WINDOW PANE - BROKEN. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION BASEMENT WINDOW- BROKEN GLASS BLOCK. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH PORCH : UNDERSIZED 6"X6" BEAMS SPAN 7'-3".. PERMIT REQUIRED FOR PORCH REPAIRS. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | WEST AND NORTH DOOR GATES AND WEST EXTERIOR DOOR - RUSTED. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR CORNICE | NORTH AND WEST ELEVATIONS - CORNICE - OPEN JOINTS AND WASHED OUT MORTAR. WEST ELEVATION / DECORATIVE CORNICE ABOVE ENTRANCE DOORS - SHIFTED WITH WASHED OUT MORTAR.MASONRY PERMIT REQUIRED FOR ALL MASONRY REPAIRS. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | NORTH AND AND SOUTH 3 STORY WOOD PORCHES / NORTH PORCH HAS 6X6 CORNER COLUMN AT 3RD FLOOR - NOTCHED AROUND RIM JOIST. TREADS AND DECKING - ROTTING, SPLIT WITH GREEN SUBSTANCE ON SURFACE. GUARD RAILS AT 2ND AND 3RD FLOORS - LOOSE AND PULLING. SOME GUARD RAILS MEASURE ONLY 36 INCHES. ALL RAILING SAYSTEMS - FASTENED WITH SCREWS ONLY. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | WEST AND NORTH DOOR GATES AND WEST EXTERIOR DOOR - RUSTED.NORTHWEST ELEVATION / 2001 E. COMMERCIAL SPACE / FRONT ENTRY DOOR DOES NOT LATCH. | 2001 E 75TH ST | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR OF BUILDING/1ST FLOOR STORE FRONTS ALTERED-2001 AND 2003 E STORE FRONTS CONVERTED INTO ONE STORE FRONT 7505 S STORE FRONT NORTH FIREWALL BREACHED ALL THESE ALTERATIONS COMPLETED WITHOUT PERMITS SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO 1ST FLOOR OR RESTORE THE BUILDING TO THE ORIGINAL STATE | 2001 E 75TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S ID SIGN - MISSING. SIGNS THAT ATRE POSTED ARE SEVERLY FADED AND UNABLE TO READ. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR LINTELS | 2001 E.AT COMERCIAL SPACE / STEEL LINTELS ABOVE FRONT ENTRY DOOR - RUSTED, SAGGING AND DETERIORATED. WEST ELEVATION AT 7505 S. / 1ST FLOOR LINTEL SAGGING RUSTED AND DETERIORATEDPLANS AND PERMIT REQUIRED TO REPAIR LINTELS. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 2001 E 75TH ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY CONDITION OF INTERIOR STAIRWAYS AND BASEMENTS. UNABLE TO VERIFY OF COMPLAINT ON SR # 182108712 FOR WATER LEAKING IN BATHROOM CEILING LIGHT IN APT. - B5. | 2001 E 75TH ST | PERIODIC | FAILED | View |
NO POSTED ADDRESS | NORTHWEST ELEVATION / COMMERCIAL SPACE AT GRADE / ADDRESS - MISSING. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION / 1ST AND 3RD FLOORS / WINDOWS - BROKEN PANES. 1ST FLOOR - BOARDED WITH PLYWOOD. | 2001 E 75TH ST | PERIODIC | FAILED | View |
RAT STOP AROUND EXTERIOR | WEST ELEVATION AT GRADE - GAPS UP TO 2 INCHES ALONG FOUNDATION. | 2001 E 75TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | ARRANGE FOR INTERIOR INSPECTION TO VERIFY DETECTORS AND OCCUPANCY | 2001 E 75TH ST | PERIODIC | FAILED | View |
FLAKY INTERIOR PAINT | 2001-UNDER AWNING-FLAKING PAINT AND AT AREA WALL | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST-AT GRADE GLASS BLOCKS BROKEN-NEAR ALLEY | 2001 E 75TH ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER PROPERTY FROM 2006 THROUGH 2007 | 2001 E 75TH ST | PERIODIC | FAILED | View |
LOOSE PLATE GLASS | 2001 1ST BROKEN PLATE GLASS | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR CORNICE | NORTH AND WEST ELEVATIONS - CORNICE - OPEN JOINTS AND WASHED OUT MORTAR. | 2001 E 75TH ST | PERIODIC | FAILED | View |
STOP LEAKING WATER | 7503 S. AND 7505 S. / STORE FRONT - WATER LEAKING THROUGH THE CEILINGS. | 2001 E 75TH ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NO REGISTRATION FROM 1990 THROUGH 2016. | 2001 E 75TH ST | PERIODIC | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS - TORN AND MISSING WINDOW SCREENS. | 2001 E 75TH ST | PERIODIC | FAILED | View |
PROTECT SIDEWALK DURING CONST | NORTH AND WEST EELEVATIONS / INSTALL PROTECTIVE CANOPY OVER PUBLIC SIDEWALK. PERMIT ISSUED BY DEPT. OF TRANSPORTATION REQUIRED FOR THIS INSTALLATION. | 2001 E 75TH ST | PERIODIC | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRICAL INSTALLED IN THE 1ST FLOOR WITHOUT A PERMIT | 2001 E 75TH ST | COMPLAINT | FAILED | View |