Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | BASEMENT STAIRS FRACTURED TREADS REAR 1149 NOT PORCH SYSTEM. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH RAILING 36 INCHES HIGH 1147 1/2 ALSO MISSING JOIST HANGERS 1145-49, 1149-1147 MISSING LAG BOLTS FROM LEDGER BOARDS. PERMIT NEEDED NO PLANS NEEDED. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR OR REPLACE | MISSING DOWNSPOUT SECTION EAST AT ALLEY SEC. 18-29-1101.2.1 | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
RATS | 1147 1/2 2ND RATS | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BROKEN WALL KITCHEN 1147 1/2 2ND FLOOR. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
SAFE WORKING CONDITIONS | BROKEN RADIATOR MISSING COVER KITCHEN 1147 1/2 2ND FLOOR. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | LOOSE TREAD FRONT STAIRS GRADE TO FIRST 1149 INTERIOR. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR SKYLIGHT | REAR DOOR LOCK 1147 1/2 2ND FLOOR. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | MISSING DETECTOR FRONT STAIRWAY 1145 MISSING FROM THIRD FLOOR. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR SILL | MISSING CLOSING DEVICE FRONT ENTRANCE DOOR 1147 1/2. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | BASEMENT STAIRS FRACTURED TREADS REAR 1149 NOT PORCH SYSTEM. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR SILL | MISSING CLOSING DEVICE FRONT ENTRANCE DOOR 1147 1/2. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | (SR#802173325) FRONT THRU WAY GATE - DOURLE ISEY LOCKED. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR COPING | WEST ELEVATION -BROKEN COPING TILE. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1145 N/RESIDENTIAL ENTRY WAY/ 2ND FLOOR WINDOW BROKEN PANE. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | 1145 N/ 1147 1/2 N/1149 N/ EXTERIOR ENTRY DOORS -BROKEN AND MISSING PANES. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR LINTELS | 1151 N/ NEW RESIDENTAIL UNIT/ ENTRY WAY LINTEL - RUSTING AND SAGGING. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
MAINTAIN WINDOW | NORTH ELEVATION/WINDOW FRAMES - PEELING PAINT. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR GUTTER | NORTH ELEVATION/GUTTERS-RUSTING. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | FOR REAR EXTERIOR PORCHES/COLUMNS-CRACKED ON SERVICE WALK FOUNDATION STATUS UNKNOWN. COLUMNS ARE TWISTING AND SPLITTING WIT SPLINTS UP TO 41 INCHES LONG. COLUMN HAF LAP JOINTS FASTENED WITH TWO 1/2 INCH BOLTS WITH OVERLAPS OF 12 INCHES. COLUMNS HAVE 2X8 RIM JOISTS LET IN AT 4 INCHES FROM HALP LAP JOINTS. BCDM TO COLUMNS CONNECTIONS AT ROOF - TECH NAILED ONLY. UNDERSIZED 2X8 DECK JOISTS SPAN 15 FEET. 4X4 COLUMNS HALF LAP JOINTS ARC NAILED ONLY WITH OVERLAPS OF 10 INCHES. STRUBGERS - AT COLUMNS AND WALLS FASTNED WITH NAIL ONLY. TRESOR-91/2 INCHES WIDE. RAILING SECTIONS- LOOSE, PULLING TOE NAILED ONLY AND ONLY 36 INCHES HIGH. GUARDS-FASTENED TO BUILDING WITH NAILS ONLY. PLANS AND PERMIT REQUIRED FOR REPAIRS TO 40 EXTERIOR PORCHES. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | 1147 1/2 N/ 1149 N/ FRONT ENTRYWAYS/EXIT OUT OF SERVICE. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
RESTORE EXIT AND EM | 1149 N./ INTERIOR STAIRWAY/ EMERGENCY LIGHTS- OUT OF SERVICE. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 1149 N/INTERIOR STAIRWAY/RAILING SECTIONS-LOOSE PULLING WITH MISSING PICKETS. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
MICE/RODENTS | 1149 N/ APARTMENT D1 - RODENT INFESTATION. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 1149 N/ APARTMENT D1 - HOT WATER 101P. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR FLOOR | 1149 N/ APARTMENT D1/FRONT ROOMS SAGGING | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | MOST APARTMENTS - NO REPONSE UNVEKEPIED DETECTORS AND CONDITIONS UNABLE TO INSPECT MOST INTERIOR STAIRWAYS. NO ENTRY TO 2 NORTH EXTERIOR OR PORCHES, VISUAL INSPECTION ONLY FROM BUS TURN AROUND AREA. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | (SR#802173325) FRONT THRU WAY GATE - DOUBLE KEY LOCKED. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
FIRE DAMAGE, SINGED,SOOT | FIRE DAMAGE AT 1147 2ND AND 3RD FLOOR. SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR LINTELS | 1151 N/ NON RESIDENTAIL UNIT/ ENTRY WAY LINTEL - RUSTING AND SAGGING. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 3 STORY OPEN WOOD PORCHES 2 AT NORTH ELEVATION ARE TYPICAL; FOUNDATION STATUS IS UNKNOWN. RAILS ARE 37" HIGH AND 14' LONG, THEY DEFLECT UNDER PRESSURE AND HAVE WEAK NAILED CONNECTIONS. 2X8 JOIST SPAN 11'. 6X6 COLUMNS HAVE INADEQUATE 12'' LAP JOINTS. ALL CONNECTION POINTS ARE MADE BY NAILS. SUBMIT PLANS AND OBTAIN PERMIT. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | 1145 N/ 1147 1/2 N/1149 N/ EXTERIOR ENTRY DOORS -BROKEN AND MISSING PANES. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | 1147 1/2 APT C1, BEDROOM DOOR IS BROKEN. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR GUTTER | NORTH ELEVATION/GUTTERS-RUSTING. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | FLOWER SHOP HAS VARIOUS WATER STAINED CEILING TILES. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | STORE AT 1151 BROKEN WINDOW, NORTH ELEVATION 3RD FLOOR, WEST ELEVATION 2ND FLOOR. 1147 1/2 C1 EAST WINDOW BROKEN. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
MAINTAIN WINDOW | NORTH ELEVATION/WINDOW FRAMES - PEELING PAINT. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENRTY TO MOST UNITS. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | ID IS NOT POSTED. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | 1147 1/2 APT C1, MISSING DETECTOR. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | NOT REGISTERED FROM 1990 TO 2010. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
EXPOSED WIRING | 1145 N/1151 N / NON RESIDENTIAL UNITS/ABOVE DOORWAY EXPOSED WIRING. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR SCREENS | 1147 1/2 APT C1, SCREEN MISSING ON REAR DOOR. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING HAS NOT BEEN REGISTERED FOR YEARS 1990 THRU 2011. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | BUILDING FRONT EXTERIOR WALLS WITH MUCH DAMAGE ON ALL LIMESTONE WALLS COMPONENTS. 1ST FLOOR SECTIONS OF THE WALLS HAVE BEEN REMOVED -WITH MANY LOOSE BRICKS, EXPOSED STEEL BEAMS ALL RUSTED MUCH DAMAGED SHOWING. DANGEROUS AND HAZZARDOUS PLANS AND PERMITS ARE REQUIRRED TO MAKE ALL NECESSARY REPAIRS ON FACADE | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | NORTH AND SOUTH ELEVATIONS - 4 WOOD PORCHES WITH SAME VIOLATIONS, 6X6 COLUMNS HAVE BEEN NOTCHED FOR BEAMS - ALL DOUBLE CUT AT CORNER CONNECTIONS ERECTED ON CONCRETE BLOCKS WITH FOUNDATION STATUS UNKNOWN. 2X8 FLOOR JOISTS ARE BEING USED SPANNING 11'. ALL GUARD RAILS ARE 37" IN HEIGHT 11' IN LENGHTS TOE NAILED TO COLUMNS. 2X8X7' SINGLE BEAMS BEING USED TO SUPPORT FLOOR JOISTS AND STAIRS. PLANS AND PERMITS REQUIRRED FOR ALL REPAIRS. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING FOR 2006 | 1145 N AUSTIN BLVD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM |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| 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR ROOF STRUCTURE | NORTH AND SOUTH ELEVATIONS AT EAST AND WEST PORCHES (4 TOTAL) ROOF JOISTS ROTTED ONLY NAILED TO COLUMN TO COLUMNS | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | 1145 FRONT ABOVE WINDOWS 1ST FLOOR LOOSE STONES OPEN JOINTS | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR DOWNSPOUT | 1151-NORTH SIDE ELEVATION DOWNSPOUTS HANGING FROM BUILDING SWAYING OVER SIDEWALK (DAMAGED) | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
MAINTAIN WINDOW | 1151 NORTH WINDOW FRAMES ROTTED PEELING PAINT VARIOUS LOCATIONS INSIDE COURTYARD 1ST,2ND AND 3RD FLOORS ALL WINDOW FRAMES ROTTED AND PEELING PAINT | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | 1145 NO SMOKE DETECTORS AT TOP OF HALLWAY (STAIRWAY) | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING UNVERIFIED DETECTORS AND OCCUPANCY | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED 2005-2006 | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST MANAGEMENT SIGN IN BUILDING | 1145 N AUSTIN BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ARRANGE FOR FULL INTERIOR INSPECTION TO VERIFY COMPLIANCE WITH ORDINANCE FOR WORKING SMOKE DETECTORS IN ALL UNITS | 1145 N AUSTIN BLVD | COMPLAINT | FAILED | View |
PIGEONS-NESTING | PIDGEON FOULINGS AT PORCHES-SOUTH ELEVATIONS | 1145 N AUSTIN BLVD | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | GANG GRAFFITI ON PORCHES AND WALLS, SOUTH AND NORTH ELEVATIONS | 1145 N AUSTIN BLVD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | AT SOUTH EAST PORCH-WEAK RAILINGS; LEDGER BEAM NOT ANCHORED TO MASONRY WALL; AT SOUTH WEST PORCH-BROKEN PICKETS AT 1ST LANDING; AT NORTH EAST PORCH-LOOSE RAILINGS | 1145 N AUSTIN BLVD | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | DIST. PANEL FOR 1145 A-4 | 1145 N AUSTIN BLVD | COMPLAINT | FAILED | View |
INSTALL COVERS | COVERS MISSING ON MAIN SW BASEMENT; COVERS MISSING JUNCTION BOX BASEMENT | 1145 N AUSTIN BLVD | COMPLAINT | FAILED | View |
SERVICE DROP OUT OF REACH | SERVICE WIRES IN REACH 2ND FL REAR | 1145 N AUSTIN BLVD | COMPLAINT | FAILED | View |
PARAPET | SOUTH, AND EAST ELEVATIONS/ PARAPET WALLS- SPALLING BRICKS, WITH WASHED OUT MORTAR. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | NORTH AND SOUTH ELEVATIONS - 4 WOOD PORCHES WITH SAME VIOLATIONS, 6X6 COLUMNS HAVE BEEN NOTCHED FOR BEAMS - ALL DOUBLE CUT AT CORNER CONNECTIONS ERECTED ON CONCRETE BLOCKS WITH FOUNDATION STATUS UNKNOWN. 2X8 FLOOR JOISTS ARE BEING USED SPANNING 11'. ALL GUARD RAILS ARE 37" IN HEIGHT 11' IN LENGHTS TOE NAILED TO COLUMNS. 2X8X7' SINGLE BEAMS BEING USED TO SUPPORT FLOOR JOISTS AND STAIRS. PLANS AND PERMITS REQUIRRED FOR ALL REPAIRS. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR CORNICE | WEST ELEVATION/ CORNICES, AND EXTERIOR WALLS- FRACTURED MASONRY, WITH WASHED OUT MORTAR. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | MOST APARTMENTS- NO RESPONSE, UNVERIFIED DETECTORS, AND CONDITIONS. UNABLE TO INSPECT MOST INTERIOR STAIRWAYS, AND 4 EXTERIOR 3 STORY PORCHES. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | BUILDING FRONT EXTERIOR WALLS WITH MUCH DAMAGE ON ALL LIMESTONE WALLS COMPONENTS. 1ST FLOOR SECTIONS OF THE WALLS HAVE BEEN REMOVED -WITH MANY LOOSE BRICKS, EXPOSED STEEL BEAMS ALL RUSTED MUCH DAMAGED SHOWING. DANGEROUS AND HAZZARDOUS PLANS AND PERMITS ARE REQUIRRED TO MAKE ALL NECESSARY REPAIRS ON FACADE | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
CONNECT DOWNSPOUT TO SEWER | EAST ELEVATION- DOWNSPOUTS DRAINING INTO PUBLIC ALLEY. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | AT BASEMENT BEHIND FLORAL SHOP-OPEN CEILING | 1145 N AUSTIN BLVD | COMPLAINT | FAILED | View |
EXPOSED WIRING | 1145 N/1151 N / NON RESIDENTIAL UNITS/ABOVE DOORWAY EXPOSED WIRING. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING 2005-2006-2004. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTRED 1990-2008. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |
DEFECTIVE FIXTURES | 1147 1/2 APT C1, BATHROOM LIGHT HAS WATER IN IT. | 1145 N AUSTIN BLVD | PERIODIC | FAILED | View |