Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 10:02 AM
PIN: 16054000020000
Property Address: 1145 N AUSTIN BLVD
City - Zip: CHICAGO - 60651
2023 Property Class: 318
2023 Township: 77 - West Chicago
2023 Neighborhood: 77013
2023 Tax District: 77001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 74 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR STAIR BASEMENT STAIRS FRACTURED TREADS REAR 1149 NOT PORCH SYSTEM. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCH RAILING 36 INCHES HIGH 1147 1/2 ALSO MISSING JOIST HANGERS 1145-49, 1149-1147 MISSING LAG BOLTS FROM LEDGER BOARDS. PERMIT NEEDED NO PLANS NEEDED. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR OR REPLACE MISSING DOWNSPOUT SECTION EAST AT ALLEY SEC. 18-29-1101.2.1 1145 N AUSTIN BLVD PERIODIC FAILED View
RATS 1147 1/2 2ND RATS 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING BROKEN WALL KITCHEN 1147 1/2 2ND FLOOR. 1145 N AUSTIN BLVD PERIODIC FAILED View
SAFE WORKING CONDITIONS BROKEN RADIATOR MISSING COVER KITCHEN 1147 1/2 2ND FLOOR. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM LOOSE TREAD FRONT STAIRS GRADE TO FIRST 1149 INTERIOR. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR SKYLIGHT REAR DOOR LOCK 1147 1/2 2ND FLOOR. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS MISSING DETECTOR FRONT STAIRWAY 1145 MISSING FROM THIRD FLOOR. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR EXTERIOR DOOR SILL MISSING CLOSING DEVICE FRONT ENTRANCE DOOR 1147 1/2. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR EXTERIOR STAIR BASEMENT STAIRS FRACTURED TREADS REAR 1149 NOT PORCH SYSTEM. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR EXTERIOR DOOR SILL MISSING CLOSING DEVICE FRONT ENTRANCE DOOR 1147 1/2. 1145 N AUSTIN BLVD PERIODIC FAILED View
NO KEY TO USE EXIT DOOR (SR#802173325) FRONT THRU WAY GATE - DOURLE ISEY LOCKED. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR COPING WEST ELEVATION -BROKEN COPING TILE. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1145 N/RESIDENTIAL ENTRY WAY/ 2ND FLOOR WINDOW BROKEN PANE. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR EXTERIOR DOOR 1145 N/ 1147 1/2 N/1149 N/ EXTERIOR ENTRY DOORS -BROKEN AND MISSING PANES. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR LINTELS 1151 N/ NEW RESIDENTAIL UNIT/ ENTRY WAY LINTEL - RUSTING AND SAGGING. 1145 N AUSTIN BLVD PERIODIC FAILED View
MAINTAIN WINDOW NORTH ELEVATION/WINDOW FRAMES - PEELING PAINT. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR GUTTER NORTH ELEVATION/GUTTERS-RUSTING. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR EXTERIOR STAIR FOR REAR EXTERIOR PORCHES/COLUMNS-CRACKED ON SERVICE WALK FOUNDATION STATUS UNKNOWN. COLUMNS ARE TWISTING AND SPLITTING WIT SPLINTS UP TO 41 INCHES LONG. COLUMN HAF LAP JOINTS FASTENED WITH TWO 1/2 INCH BOLTS WITH OVERLAPS OF 12 INCHES. COLUMNS HAVE 2X8 RIM JOISTS LET IN AT 4 INCHES FROM HALP LAP JOINTS. BCDM TO COLUMNS CONNECTIONS AT ROOF - TECH NAILED ONLY. UNDERSIZED 2X8 DECK JOISTS SPAN 15 FEET. 4X4 COLUMNS HALF LAP JOINTS ARC NAILED ONLY WITH OVERLAPS OF 10 INCHES. STRUBGERS - AT COLUMNS AND WALLS FASTNED WITH NAIL ONLY. TRESOR-91/2 INCHES WIDE. RAILING SECTIONS- LOOSE, PULLING TOE NAILED ONLY AND ONLY 36 INCHES HIGH. GUARDS-FASTENED TO BUILDING WITH NAILS ONLY. PLANS AND PERMIT REQUIRED FOR REPAIRS TO 40 EXTERIOR PORCHES. 1145 N AUSTIN BLVD PERIODIC FAILED View
MAINTAIN EXIT SIGN ILLUMINATED 1147 1/2 N/ 1149 N/ FRONT ENTRYWAYS/EXIT OUT OF SERVICE. 1145 N AUSTIN BLVD PERIODIC FAILED View
RESTORE EXIT AND EM 1149 N./ INTERIOR STAIRWAY/ EMERGENCY LIGHTS- OUT OF SERVICE. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM 1149 N/INTERIOR STAIRWAY/RAILING SECTIONS-LOOSE PULLING WITH MISSING PICKETS. 1145 N AUSTIN BLVD PERIODIC FAILED View
MICE/RODENTS 1149 N/ APARTMENT D1 - RODENT INFESTATION. 1145 N AUSTIN BLVD PERIODIC FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG 1149 N/ APARTMENT D1 - HOT WATER 101P. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR FLOOR 1149 N/ APARTMENT D1/FRONT ROOMS SAGGING 1145 N AUSTIN BLVD PERIODIC FAILED View
ARRANGE PREMISE INSPECTION MOST APARTMENTS - NO REPONSE UNVEKEPIED DETECTORS AND CONDITIONS UNABLE TO INSPECT MOST INTERIOR STAIRWAYS. NO ENTRY TO 2 NORTH EXTERIOR OR PORCHES, VISUAL INSPECTION ONLY FROM BUS TURN AROUND AREA. 1145 N AUSTIN BLVD PERIODIC FAILED View
NO KEY TO USE EXIT DOOR (SR#802173325) FRONT THRU WAY GATE - DOUBLE KEY LOCKED. 1145 N AUSTIN BLVD PERIODIC FAILED View
FIRE DAMAGE, SINGED,SOOT FIRE DAMAGE AT 1147 2ND AND 3RD FLOOR. SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR LINTELS 1151 N/ NON RESIDENTAIL UNIT/ ENTRY WAY LINTEL - RUSTING AND SAGGING. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR PORCH SYSTEM 3 STORY OPEN WOOD PORCHES 2 AT NORTH ELEVATION ARE TYPICAL; FOUNDATION STATUS IS UNKNOWN. RAILS ARE 37" HIGH AND 14' LONG, THEY DEFLECT UNDER PRESSURE AND HAVE WEAK NAILED CONNECTIONS. 2X8 JOIST SPAN 11'. 6X6 COLUMNS HAVE INADEQUATE 12'' LAP JOINTS. ALL CONNECTION POINTS ARE MADE BY NAILS. SUBMIT PLANS AND OBTAIN PERMIT. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR EXTERIOR DOOR 1145 N/ 1147 1/2 N/1149 N/ EXTERIOR ENTRY DOORS -BROKEN AND MISSING PANES. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR EXTERIOR DOOR 1147 1/2 APT C1, BEDROOM DOOR IS BROKEN. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR GUTTER NORTH ELEVATION/GUTTERS-RUSTING. 1145 N AUSTIN BLVD PERIODIC FAILED View
INT WALL/CEILING PEELING PAINT FLOWER SHOP HAS VARIOUS WATER STAINED CEILING TILES. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS STORE AT 1151 BROKEN WINDOW, NORTH ELEVATION 3RD FLOOR, WEST ELEVATION 2ND FLOOR. 1147 1/2 C1 EAST WINDOW BROKEN. 1145 N AUSTIN BLVD PERIODIC FAILED View
MAINTAIN WINDOW NORTH ELEVATION/WINDOW FRAMES - PEELING PAINT. 1145 N AUSTIN BLVD PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENRTY TO MOST UNITS. 1145 N AUSTIN BLVD PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# ID IS NOT POSTED. 1145 N AUSTIN BLVD PERIODIC FAILED View
INSTALL SMOKE DETECTORS 1147 1/2 APT C1, MISSING DETECTOR. 1145 N AUSTIN BLVD PERIODIC FAILED View
FILE BLDG REGISTRATION NOT REGISTERED FROM 1990 TO 2010. 1145 N AUSTIN BLVD PERIODIC FAILED View
EXPOSED WIRING 1145 N/1151 N / NON RESIDENTIAL UNITS/ABOVE DOORWAY EXPOSED WIRING. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR SCREENS 1147 1/2 APT C1, SCREEN MISSING ON REAR DOOR. 1145 N AUSTIN BLVD PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING HAS NOT BEEN REGISTERED FOR YEARS 1990 THRU 2011. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR EXTERIOR WALL BUILDING FRONT EXTERIOR WALLS WITH MUCH DAMAGE ON ALL LIMESTONE WALLS COMPONENTS. 1ST FLOOR SECTIONS OF THE WALLS HAVE BEEN REMOVED -WITH MANY LOOSE BRICKS, EXPOSED STEEL BEAMS ALL RUSTED MUCH DAMAGED SHOWING. DANGEROUS AND HAZZARDOUS PLANS AND PERMITS ARE REQUIRRED TO MAKE ALL NECESSARY REPAIRS ON FACADE 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR PORCH SYSTEM NORTH AND SOUTH ELEVATIONS - 4 WOOD PORCHES WITH SAME VIOLATIONS, 6X6 COLUMNS HAVE BEEN NOTCHED FOR BEAMS - ALL DOUBLE CUT AT CORNER CONNECTIONS ERECTED ON CONCRETE BLOCKS WITH FOUNDATION STATUS UNKNOWN. 2X8 FLOOR JOISTS ARE BEING USED SPANNING 11'. ALL GUARD RAILS ARE 37" IN HEIGHT 11' IN LENGHTS TOE NAILED TO COLUMNS. 2X8X7' SINGLE BEAMS BEING USED TO SUPPORT FLOOR JOISTS AND STAIRS. PLANS AND PERMITS REQUIRRED FOR ALL REPAIRS. 1145 N AUSTIN BLVD PERIODIC FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING FOR 2006 1145 N AUSTIN BLVD COMPLAINT FAILED View
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iew
REPAIR ROOF STRUCTURE NORTH AND SOUTH ELEVATIONS AT EAST AND WEST PORCHES (4 TOTAL) ROOF JOISTS ROTTED ONLY NAILED TO COLUMN TO COLUMNS 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR EXTERIOR WALL 1145 FRONT ABOVE WINDOWS 1ST FLOOR LOOSE STONES OPEN JOINTS 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR DOWNSPOUT 1151-NORTH SIDE ELEVATION DOWNSPOUTS HANGING FROM BUILDING SWAYING OVER SIDEWALK (DAMAGED) 1145 N AUSTIN BLVD PERIODIC FAILED View
MAINTAIN WINDOW 1151 NORTH WINDOW FRAMES ROTTED PEELING PAINT VARIOUS LOCATIONS INSIDE COURTYARD 1ST,2ND AND 3RD FLOORS ALL WINDOW FRAMES ROTTED AND PEELING PAINT 1145 N AUSTIN BLVD PERIODIC FAILED View
INSTALL SMOKE DETECTORS 1145 NO SMOKE DETECTORS AT TOP OF HALLWAY (STAIRWAY) 1145 N AUSTIN BLVD PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING UNVERIFIED DETECTORS AND OCCUPANCY 1145 N AUSTIN BLVD PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED 2005-2006 1145 N AUSTIN BLVD PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# POST MANAGEMENT SIGN IN BUILDING 1145 N AUSTIN BLVD COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION ARRANGE FOR FULL INTERIOR INSPECTION TO VERIFY COMPLIANCE WITH ORDINANCE FOR WORKING SMOKE DETECTORS IN ALL UNITS 1145 N AUSTIN BLVD COMPLAINT FAILED View
PIGEONS-NESTING PIDGEON FOULINGS AT PORCHES-SOUTH ELEVATIONS 1145 N AUSTIN BLVD COMPLAINT FAILED View
STOP/REMOVE NUISANCE GANG GRAFFITI ON PORCHES AND WALLS, SOUTH AND NORTH ELEVATIONS 1145 N AUSTIN BLVD COMPLAINT FAILED View
REPAIR PORCH SYSTEM AT SOUTH EAST PORCH-WEAK RAILINGS; LEDGER BEAM NOT ANCHORED TO MASONRY WALL; AT SOUTH WEST PORCH-BROKEN PICKETS AT 1ST LANDING; AT NORTH EAST PORCH-LOOSE RAILINGS 1145 N AUSTIN BLVD COMPLAINT FAILED View
DEFECTIVE DISTRIBUTION DIST. PANEL FOR 1145 A-4 1145 N AUSTIN BLVD COMPLAINT FAILED View
INSTALL COVERS COVERS MISSING ON MAIN SW BASEMENT; COVERS MISSING JUNCTION BOX BASEMENT 1145 N AUSTIN BLVD COMPLAINT FAILED View
SERVICE DROP OUT OF REACH SERVICE WIRES IN REACH 2ND FL REAR 1145 N AUSTIN BLVD COMPLAINT FAILED View
PARAPET SOUTH, AND EAST ELEVATIONS/ PARAPET WALLS- SPALLING BRICKS, WITH WASHED OUT MORTAR. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR PORCH SYSTEM NORTH AND SOUTH ELEVATIONS - 4 WOOD PORCHES WITH SAME VIOLATIONS, 6X6 COLUMNS HAVE BEEN NOTCHED FOR BEAMS - ALL DOUBLE CUT AT CORNER CONNECTIONS ERECTED ON CONCRETE BLOCKS WITH FOUNDATION STATUS UNKNOWN. 2X8 FLOOR JOISTS ARE BEING USED SPANNING 11'. ALL GUARD RAILS ARE 37" IN HEIGHT 11' IN LENGHTS TOE NAILED TO COLUMNS. 2X8X7' SINGLE BEAMS BEING USED TO SUPPORT FLOOR JOISTS AND STAIRS. PLANS AND PERMITS REQUIRRED FOR ALL REPAIRS. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR CORNICE WEST ELEVATION/ CORNICES, AND EXTERIOR WALLS- FRACTURED MASONRY, WITH WASHED OUT MORTAR. 1145 N AUSTIN BLVD PERIODIC FAILED View
ARRANGE PREMISE INSPECTION MOST APARTMENTS- NO RESPONSE, UNVERIFIED DETECTORS, AND CONDITIONS. UNABLE TO INSPECT MOST INTERIOR STAIRWAYS, AND 4 EXTERIOR 3 STORY PORCHES. 1145 N AUSTIN BLVD PERIODIC FAILED View
REPAIR EXTERIOR WALL BUILDING FRONT EXTERIOR WALLS WITH MUCH DAMAGE ON ALL LIMESTONE WALLS COMPONENTS. 1ST FLOOR SECTIONS OF THE WALLS HAVE BEEN REMOVED -WITH MANY LOOSE BRICKS, EXPOSED STEEL BEAMS ALL RUSTED MUCH DAMAGED SHOWING. DANGEROUS AND HAZZARDOUS PLANS AND PERMITS ARE REQUIRRED TO MAKE ALL NECESSARY REPAIRS ON FACADE 1145 N AUSTIN BLVD PERIODIC FAILED View
CONNECT DOWNSPOUT TO SEWER EAST ELEVATION- DOWNSPOUTS DRAINING INTO PUBLIC ALLEY. 1145 N AUSTIN BLVD PERIODIC FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU AT BASEMENT BEHIND FLORAL SHOP-OPEN CEILING 1145 N AUSTIN BLVD COMPLAINT FAILED View
EXPOSED WIRING 1145 N/1151 N / NON RESIDENTIAL UNITS/ABOVE DOORWAY EXPOSED WIRING. 1145 N AUSTIN BLVD PERIODIC FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING 2005-2006-2004. 1145 N AUSTIN BLVD PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTRED 1990-2008. 1145 N AUSTIN BLVD PERIODIC FAILED View
DEFECTIVE FIXTURES 1147 1/2 APT C1, BATHROOM LIGHT HAS WATER IN IT. 1145 N AUSTIN BLVD PERIODIC FAILED View