Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSPECT CONSTRUCTION WORK | WORK CONTRARY TO PLANS REVISE PORCH PER PLANS AND ARRANGE FINAL INSP | 4123 W WASHINGTON BLVD | PERMIT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH-STRINGERS UNDERSIZED.DEFICIENT BEAM COLUMN CONNECTION.COLUMNS OVERNOTCHED.9 INCH TREADS.NO BOLTED CONNECTIONS AT STRINGER TO LANDINGS.PLANS AND PERMITS REQUIRED TO REPAIR OR REPLACE PORCH | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ERODED MORTAR | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | MAIN ENTRY DOOR FRAME DAMAGED AT STRIKE PLATES | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | MAIN ENTRY DOOR LOCK INOPERABLE | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | INTERIOR STAIRWELL-MISSING SMOKE DETECTOR | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | NORTH AND WEST WINDOW SILLS - WASHED OUT MORTAR. | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
PARAPET | WEST PARAPET WALL - WASHED OUT MORTAR. | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - MISSING OWNER'S ID. SIGN. | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY - LEANING; SPALLING BRICKS AND WASHED OUT MORTAR. | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
REPAIR FLOOR | 4TH FLOOR DINNING ROOM HARDWOOD FLOOR - LOOSE BOARDS. | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
ROACHES | BUILDING INFESTED WITH ROACHES - INCLUDING 4TH FLOOR APT. | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY - MISSING SMOKE DETECTOR. | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | COLUMNS ARE ERECTED ON TOP OF CONCRETE SLAB; FOOTING STATUS UNKNOWN.; UNDERSIZED 2"X8" DECK JOISTS SPAN 11'-9".; UNDERSIZED 6"X6" BEAMS SPAN 6'-7-1/2".; TREADS ARE ONLY 9-1/2" WIDE.; STRINGERS ARE FASTENED WITH NAILS ONLY AND ARE CRACKED GRADE TO 1ST; RIM JOIST ARE FASTENED TO COLUMNS WITH NAILS ONLY.; RAILINGS HORIZONTAL TIES ARE TOE-NAILED ONLY AND ARE FASTENED TO EXTERIOR WALL WITH NAILS ONLY; HANDRAIL 3RD FLOOR, BROKEN AND LOOSE PICKETS.PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 3RD AND 4TH FLOOR APARTMENT DOORS - MISSING VIEWING DEVICES. | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION 2ND FLOOR - BROKEN GLASS PANE. | 4123 W WASHINGTON BLVD | COMPLAINT | FAILED | View |