Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 7:19 PM
PIN: 20044070080000
Property Address: 4353 S SHIELDS AVE
City - Zip: CHICAGO - 60609
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72293
2023 Tax District: 72214
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 25 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S ID SIGN POSTED. 4353 S SHIELDS AVE COMPLAINT CLOSED View
STOP LEAKING WATER BASEMENT APARTMENT - WATER LEAKING FROM PIPES. 4353 S SHIELDS AVE COMPLAINT CLOSED View
REPAIR INTERIOR WALLS/CEILING BASEMENT APARTMENT CEILING - WATER DAMAGE THROUGHOUT. 4353 S SHIELDS AVE COMPLAINT CLOSED View
INSTALL SMOKE DETECTORS BASEMENT APARTMENT - MISSING SMOKE DETECTOR. 4353 S SHIELDS AVE COMPLAINT CLOSED View
CARB MONOX DETECT IN RESID BASEMENT APARTMENT - MISSING CARBON MONOXIDE DETECTOR. 4353 S SHIELDS AVE COMPLAINT CLOSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING ALL PLUMBING AND ELECTRICAL) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. 4353 S SHIELDS AVE COMPLAINT CLOSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 4353 S SHIELDS AVE COMPLAINT CLOSED View
DEBRIS, EXCESSIVE REAR YARD AND PARKING AREA - TRASH AND JUNK PILES. 4353 S SHIELDS AVE COMPLAINT CLOSED View
HEAT UNIT ADEQUATELY 1ST. FL. /ROOM TEMP. ¿ 57F. AT 1:55PM. REAR LAUNDRY ROOM /ROOM TEMP. 36F. AT 1:56PM. HEATING SYSTEM IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED. 4353 S SHIELDS AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS 1ST. FL. /FURNACE - BROKEN, OUT OF SERVICE AT TIME OF INSPECTION. 4353 S SHIELDS AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE 1ST. FL. /USING ELECTRIC SPACE HEATERS AT TIME OF INSPECTION. 4353 S SHIELDS AVE COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG 1ST. FL. /HOT WATER SUPPLY ¿ INSUFFIENT TEMPERATURE OF 49F AT 2:00PM. NO HOT WATER FURNISHED. 4353 S SHIELDS AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE 1ST. FL. /FRONT AND REAR EXTERIOR DOORS - TOO SMALL FOR FRAME, WITH GAPS AT JAMS AND BOTTOM. 4353 S SHIELDS AVE COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTION REQUIRED 13-32-270 WARM AIR FURNACES *ARRANGE FOR COMPLETE PERMIT INSPECTION AND OBTAIN PERMIT FOR WARM AIR HEATING SYSTEMS AND VENTILATION SYSTEMS WHEN WORK IS COMPLETED 4353 S SHIELDS AVE COMPLAINT PASSED View
OPEN TYPE VIOLATION (VT 2034) 18-28-3070.2.2 AUXILIARY DRAIN PANS * AUXILIARY DRAIN PANS TO BE 3" LARGER THAN THE COIL UNIT AND WIDTH AND HAVE A MINIMUM DEPT OF 1-1/2" (FURNACE CANNOT SIT ON COMBUSTIBLE MATERIAL) 4353 S SHIELDS AVE COMPLAINT PASSED View
GIVE VENT OPENINGS % FL. AREA 18-28-403.3 VENTILATION REQUIREMENTS PROVIDE VENTILATION OPENING EQUAL TO A FIXED PERCENTAGE OF FLOOR AREA) HABITABLE ROOM IN ATTIC HAS NO WINDOWS AND REQUIRES 8% LIGHT AND 4% INHABITABLE ROOM 4353 S SHIELDS AVE COMPLAINT PASSED View
OPEN TYPE VIOLATION (VT 7024) 18-28-603.15 REGISTERS, GRILLES AND DIFFUSERS *FLOOR REGISTERS SHALL RESIST, WITHOUT STRUCTURAL A 200 LB LOAD ON A 2" DIAMETER DISC APPLIED TO THE MOST CRITICAL AREA OF THE EXPOSED FACE 4353 S SHIELDS AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. REAR YARD - LOCKED GATES, UNABLE TO INSPECT REAR PORCH. 4353 S. / 1ST FLOOR APARTMENT - NO ENTRY, UNABLE TO VERIFY COMPLAINT OF MISSING BANISTER, MISSING CARBON MONOXIDE DETECTORS; HOLES IN THE WALLS. 4353 S SHIELDS AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS ALL ELEVATIONS / MULTIPLE LOCATIONS / WINDOW SCREENS - MISSING. 4353 S SHIELDS AVE COMPLAINT FAILED View
REPAIR SCREENS ALL ELEVATIONS / MULTIPLE LOCATIONS / WINDOW SCREENS - RIPPED. 4353 S SHIELDS AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT PORCH GRADE TO 1ST FLOOR. GUARD RAILS NAILED TO STRINGERS.GUARD RAILS NAILED TO WALL .5 TREADS CRACKED AND LOOSE. GUARD RAILS AT FRONT NOT LONG ENOUGH NEAR 1ST TREAD.REAR PORCH GRADE TO 1ST FLOOR FL4X4 COLUMNS ERECTED ON DIRT AND FOUNDATION STATUS UNKNOWN.1ST FLOOR HEADERS MISSING ANGLE BRACKET.GUARD RAILS NAILED TO STRINGER.AND PICKETS MISSING AND LOOSE.GUARD RAILS AND BOTTOM LANDING NOT LONG ENOUGHPERMIT REQUIRED FOR REPAIRS TO FRONT AND REAR PORCH.. 4353 S SHIELDS AVE COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 4353 S SHIELDS AVE PERMIT PASSED View
ARRANGE COMPLETED PERMIT INSP. 4353 S SHIELDS AVE PERMIT PASSED View
SEE INSPECTOR COMMENTS 4353 S SHIELDS AVE PERMIT PASSED View
SEE INSPECTOR COMMENTS 4353 S SHIELDS AVE PERMIT PASSED View