Chicago Building Violations Data: 39 Violations
Violation Inspector Comments Address Category Status View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND PERMITS FOR LAYOUT OF ENTIRE BUILDING ORIGINAL EIGHT FLAT NOW CONTAINS AT LEAST THIRTEEN UNITS BASEMENT UNIT ADDED AT SOUTH EAST ADDITIONAL UNITS ADDED AT SOUTH EAST ADDITIONAL UNITS ADDED TO EAST SECTION OF FIRST THROUGH THIRD FLOORS EAST UNITS ONLY ONE EGRESS 506 N MONTICELLO AVE COMPLAINT CLOSED View
SEPARATION OF DWELLING ADEQUAT BASEMENT UNIT WOOD PANEL 506 N MONTICELLO AVE COMPLAINT CLOSED View
LIGHT AND VENT BASEMENT WINDOWS DON'T MEET LIGHT/VENT REQUIREMENTS 506 N MONTICELLO AVE COMPLAINT CLOSED View
REPAIR EXTERIOR DOOR HARDWARE DOOR HARDWARE AT EAST GRADE BEDROOM ALSO 2ND FLOOR SOUTH REAR UNIT ALSO 2ND FLOOR NORTH WEST 506 N MONTICELLO AVE COMPLAINT CLOSED View
OBSTRUCTIONS IN EXIT WAY 2ND FLOOR SOUTH REAR UNIT DOOR NAILED SHUT 506 N MONTICELLO AVE COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR REAR EXTERIOR STAIR SYSTEM WITH UNEVEN RISER HEIGHT, STRINGER IMPROPERLY CUT, TREAD PITCHED FORWARD, SOME STRINGER SECTIONS LACK BOLTS AT WALL OR END ANCHOR AREAS. 2) NO FOUNDATION UNDER COLUMNS. 3) FRONT HEADER JOISTS NOT BOLTED TO COLUMNS. 506 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR OR REPLACE DISCONNECTED DOWN SPOUT SECTION, REPAIR AS PER 18-29-1101-2-1. 506 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE 07-00712415-FRONT MAIN ENTRY DOOR-BROKEN WORK. 506 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT INTERIOR STAIRS SOUTH END - MISSING HANDRAIL GRADE TO LOWER GRADE. 506 N MONTICELLO AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR BASEMENT SOUTH ELEVATION - SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 506 N MONTICELLO AVE COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT PERMIT. 506 N MONTICELLO AVE COMPLAINT FAILED View
ROACHES THRU OUT BUILDING SIGNS OF ROACHES. 506 N MONTICELLO AVE COMPLAINT FAILED View
MICE/RODENTS THRU OUT BUILDING SIGNS OF MICE. 506 N MONTICELLO AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE EXTERIOR SOUTH ELEVATION LOTS OF GARBAGE. 506 N MONTICELLO AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE MISSING VIEWING DEVICES 2ND, 3RD FLOORS. 506 N MONTICELLO AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTORS THRU OUT. 506 N MONTICELLO AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTORS THRU OUT. 506 N MONTICELLO AVE COMPLAINT FAILED View
CLS.C DOOR PRE-ORD HOTEL STAIR FRONT ENTRY DOORS ARE NOT FIRE RATED AT APT. 506 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR 3RD FLOOR 506-DAMAGED ENTRY DOOR. 506 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING 3RD FLOOR 506-HOLES IN WALLS THRU OUT APT. 506 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIRS WEAK, LOOSE GRADE TO 3RD. 506 N MONTICELLO AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR NEWLY BUILT REAR PORCH. PLANS AND PERMIT WERE NOT AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION. 506 N MONTICELLO AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING NO RESPONSE UNVERIFIED DETECTORS (OCCUPANCY, CONDITIONS UNABLE TO INSPECT INTERIOR STAIRWAYS) ALSO VERIFY PREVIOUS INTERIOR VIOLATIONS. 506 N MONTICELLO AVE COMPLAINT FAILED View
PARAPET PARAPET WALL - SPALLING BRICKS AND WASHED OUT MORTAR. 506 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR LINTELS LINTEL ABOVE DOORWAY IS RUSTED AND SAGGING, PERMIT REQUIRED FOR REPAIRS. 506 N MONTICELLO AVE COMPLAINT FAILED View
MAINTAIN PROJECTIONS LARGE STONE PROJECTION HAS SHIFTED.BL00831 506 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM 1. 6X6 COLUMNS RESTING ON CONCRETE SLAB.2. FOUNDATION STATUS UNKNOWN.3. 6X6 COLUMN BOWED AT GRADE.4. 6X6 COLUMNS OVER NOTCHED.5. STRINGERS INADEQUATELY SUPPORTED.6. 2X JOIST OVER SPANNED.7. LEDGER INADEQUATELY SUPPORTED AT BUILDING.8. PLANS AND PERMIT REQUIRED. 506 N MONTICELLO AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY FRACTURED AND BUCKLED CONCRETE PAD. 506 N MONTICELLO AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS TORN AND MISSING WINDOW SCREENS. 506 N MONTICELLO AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE SECTION OF FLUE PIPE FOR EXTERNAL CHIMNEY HANGING FROM COPING. 506 N MONTICELLO AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE, UNBVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. NO ENTRY TO BASEMENT, UNABLE TO VERIFY COMPLAINT OF NON-WORKING SMOKE DETECTORS. 506 N MONTICELLO AVE COMPLAINT FAILED View
FILE BLDG REGISTRATION NOT REGISTERED FOR 2009 AND 2010. 506 N MONTICELLO AVE COMPLAINT FAILED View
MAINTAIN PROJECTIONS EAST ELEVATION ABOVE ENRTY DOOR LARGE SECTION OF DECRETIVE LIME STONE SHIFTING. BL00831 506 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH STRUCTURE WITH THE FOLLOWING DEFECTS,1) 6X6 COLUNMS RESTING ON CONCRETE SLAB.2) FOUNDATION STATUS UNKNOWN.3) 6X6 COLUNMS BOWED AT GRADE.4) 6X6 COLUNMS OVER NOTCHED.5) STRINGERS INADEQUATELY SUPPORTED6) 2X8 JOIST OVER SPAN.7) LEDGER INADEQUATELY SUPPORTED AT BUILDING.8) PLANS AND PERMITS REQUIRED. 506 N MONTICELLO AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY REAR PARKING AREA FRACTURED,BUCKLING. 506 N MONTICELLO AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE SECTION OF EXTERNAL PIPE FOR CHIMENY HANGING FROM COPPING. 506 N MONTICELLO AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS 508 BASEMENT BOARDED UP WINDOWS. 506 N MONTICELLO AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER'S / MANAGEMENT SIGN POSTED. 506 N MONTICELLO AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS TORN OR MISSING WINDOW SCREENS. 506 N MONTICELLO AVE COMPLAINT FAILED View