Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND PERMITS FOR LAYOUT OF ENTIRE BUILDING ORIGINAL EIGHT FLAT NOW CONTAINS AT LEAST THIRTEEN UNITS BASEMENT UNIT ADDED AT SOUTH EAST ADDITIONAL UNITS ADDED AT SOUTH EAST ADDITIONAL UNITS ADDED TO EAST SECTION OF FIRST THROUGH THIRD FLOORS EAST UNITS ONLY ONE EGRESS | 506 N MONTICELLO AVE | COMPLAINT | CLOSED | View |
SEPARATION OF DWELLING ADEQUAT | BASEMENT UNIT WOOD PANEL | 506 N MONTICELLO AVE | COMPLAINT | CLOSED | View |
LIGHT AND VENT | BASEMENT WINDOWS DON'T MEET LIGHT/VENT REQUIREMENTS | 506 N MONTICELLO AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR HARDWARE | DOOR HARDWARE AT EAST GRADE BEDROOM ALSO 2ND FLOOR SOUTH REAR UNIT ALSO 2ND FLOOR NORTH WEST | 506 N MONTICELLO AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | 2ND FLOOR SOUTH REAR UNIT DOOR NAILED SHUT | 506 N MONTICELLO AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | REAR EXTERIOR STAIR SYSTEM WITH UNEVEN RISER HEIGHT, STRINGER IMPROPERLY CUT, TREAD PITCHED FORWARD, SOME STRINGER SECTIONS LACK BOLTS AT WALL OR END ANCHOR AREAS. 2) NO FOUNDATION UNDER COLUMNS. 3) FRONT HEADER JOISTS NOT BOLTED TO COLUMNS. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | DISCONNECTED DOWN SPOUT SECTION, REPAIR AS PER 18-29-1101-2-1. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | 07-00712415-FRONT MAIN ENTRY DOOR-BROKEN WORK. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT INTERIOR STAIRS SOUTH END - MISSING HANDRAIL GRADE TO LOWER GRADE. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT SOUTH ELEVATION - SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT PERMIT. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
ROACHES | THRU OUT BUILDING SIGNS OF ROACHES. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | THRU OUT BUILDING SIGNS OF MICE. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | EXTERIOR SOUTH ELEVATION LOTS OF GARBAGE. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | MISSING VIEWING DEVICES 2ND, 3RD FLOORS. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS THRU OUT. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS THRU OUT. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
CLS.C DOOR PRE-ORD HOTEL STAIR | FRONT ENTRY DOORS ARE NOT FIRE RATED AT APT. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | 3RD FLOOR 506-DAMAGED ENTRY DOOR. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 3RD FLOOR 506-HOLES IN WALLS THRU OUT APT. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRS WEAK, LOOSE GRADE TO 3RD. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | NEWLY BUILT REAR PORCH. PLANS AND PERMIT WERE NOT AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE UNVERIFIED DETECTORS (OCCUPANCY, CONDITIONS UNABLE TO INSPECT INTERIOR STAIRWAYS) ALSO VERIFY PREVIOUS INTERIOR VIOLATIONS. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALL - SPALLING BRICKS AND WASHED OUT MORTAR. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | LINTEL ABOVE DOORWAY IS RUSTED AND SAGGING, PERMIT REQUIRED FOR REPAIRS. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
MAINTAIN PROJECTIONS | LARGE STONE PROJECTION HAS SHIFTED.BL00831 | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 1. 6X6 COLUMNS RESTING ON CONCRETE SLAB.2. FOUNDATION STATUS UNKNOWN.3. 6X6 COLUMN BOWED AT GRADE.4. 6X6 COLUMNS OVER NOTCHED.5. STRINGERS INADEQUATELY SUPPORTED.6. 2X JOIST OVER SPANNED.7. LEDGER INADEQUATELY SUPPORTED AT BUILDING.8. PLANS AND PERMIT REQUIRED. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRACTURED AND BUCKLED CONCRETE PAD. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | TORN AND MISSING WINDOW SCREENS. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | SECTION OF FLUE PIPE FOR EXTERNAL CHIMNEY HANGING FROM COPING. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE, UNBVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. NO ENTRY TO BASEMENT, UNABLE TO VERIFY COMPLAINT OF NON-WORKING SMOKE DETECTORS. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | NOT REGISTERED FOR 2009 AND 2010. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
MAINTAIN PROJECTIONS | EAST ELEVATION ABOVE ENRTY DOOR LARGE SECTION OF DECRETIVE LIME STONE SHIFTING. BL00831 | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH STRUCTURE WITH THE FOLLOWING DEFECTS,1) 6X6 COLUNMS RESTING ON CONCRETE SLAB.2) FOUNDATION STATUS UNKNOWN.3) 6X6 COLUNMS BOWED AT GRADE.4) 6X6 COLUNMS OVER NOTCHED.5) STRINGERS INADEQUATELY SUPPORTED6) 2X8 JOIST OVER SPAN.7) LEDGER INADEQUATELY SUPPORTED AT BUILDING.8) PLANS AND PERMITS REQUIRED. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR PARKING AREA FRACTURED,BUCKLING. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | SECTION OF EXTERNAL PIPE FOR CHIMENY HANGING FROM COPPING. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 508 BASEMENT BOARDED UP WINDOWS. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S / MANAGEMENT SIGN POSTED. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | TORN OR MISSING WINDOW SCREENS. | 506 N MONTICELLO AVE | COMPLAINT | FAILED | View |