Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 3:56 AM
PIN: 13251020060000
Property Address: 3033 W BELMONT AVE
City - Zip: CHICAGO - 60618
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77150
2023 Tax District: 77135
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 8 Violations
Violation Inspector Comments Address Category Status View
PARAPET PARAPET MINOR FRACTURES 3033 W BELMONT AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM LOOKOUT MISSING TIES AT MORTAR POCKETS 3033 W BELMONT AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR THREE STORY PORCH, COLUMNS HALF-LAP JOINTS FASTENED WITH 3 BOLTS ONLY.UNDERSIZED 6"X6" BEAMS SPAN 6'-9".BEAMS FASTENED TO COLUMNS WITH LIGHT GAGE TIE STRAPS.UNDERSIZED 2"X8" DECK JOISTS SPAN 11'-6".GUARD RAILINGS SECTIONS ARE ONLY 38" HIGH; BOTTOM LOOSE AND PULLING AND FASTENED TO EXTERIOR WALLS WITH TAP-CON TYPE OF SCREWS ONLY AND FASTENED TO COLUMNS AND 4"X4" RAILINGS POSTS WITH NAILS ONLY.HANDRAILS GRADE TO 2ND ARE LOOSE.PLAN AND PERMIT ARE REQUIRED TO REPAIR REAR PORCH. 3033 W BELMONT AVE PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING FRONT INTERIOR STAIRWAY 2ND AND 3RD FLOOR - SECTIONS MISSING PLASTER. 3033 W BELMONT AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS FRONT INTERIOR STAIRWAY - MISSING SMOKE DETECTOR. 3033 W BELMONT AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR THREE STORY PORCH, COLUMNS HALF-LAP JOINTS FASTENED WITH 3 BOLTS ONLY.UNDERSIZED 6"X6" BEAMS SPAN 6'-9".BEAMS FASTENED TO COLUMNS WITH LIGHT GAGE TIE STRAPS.UNDERSIZED 2"X8" DECK JOISTS SPAN 11'-6".GUARD RAILINGS SECTIONS ARE ONLY 38" HIGH; BOTTOM LOOSE AND PULLING AND FASTENED TO EXTERIOR WALLS WITH TAP-CON TYPE OF SCREWS ONLY AND FASTENED TO COLUMNS AND 4"X4" RAILINGS POSTS WITH NAILS ONLY.HANDRAILS GRADE TO 2ND ARE LOOSE.PLAN AND PERMIT ARE REQUIRED TO REPAIR REAR PORCH. 3033 W BELMONT AVE PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING FRONT INTERIOR STAIRWAY 2ND AND 3RD FLOOR - SECTIONS MISSING PLASTER. 3033 W BELMONT AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION 1ST AND 2ND FLOOR - NO RESPONSE, UNVERIFIED DETECTORS. 3033 W BELMONT AVE PERIODIC FAILED View