The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VACANT BUILDING - REGISTER | 2421 N MARMORA AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 2421 N MARMORA AVE | COMPLAINT | CLOSED | View | |
OBTAIN OR POST PERMIT | 2421 N MARMORA AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 2421 N MARMORA AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 2421 N MARMORA AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 2421 N MARMORA AVE | COMPLAINT | CLOSED | View | |
WORKING ON STOP WORK ORDER | STOP WORK ORDER POSTED AT TIME OF INSPECTION . NO PLANS OR PERMITS OBTAINED . FULL REHAB OF SINGLE FAMILY INCLUDING , WOOD PORCHES , INTERIOR WALL FRAMING , PLUMBING , VENTILATION AND ELECTRICAL . | 2421 N MARMORA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT WOOD PORCH REMOVED , NO PLANS OR PERMITS OBTAINED . | 2421 N MARMORA AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIR SYSTEMS FROM BASEMENT TO FIRST FLOOR AND FIRST FLOOR TO ATTIC ONLY 30 INCHES WIDE . REQUIRES PLANS AND PERMITS FOR REPAIRS . | 2421 N MARMORA AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | INTERIOR OF BUILDING AT ATTIC , FLOOR JOIST ONLY 2 BY 6 MEMBERS , UNDERSIZED AND OVERSPANNED . BALLON FRAMED FRAMED SINGLE FAMILY BUILDING MISSING ALL FIRE STOPPING . | 2421 N MARMORA AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | STOP WORK ORDER POSTED AT TIME OF INSPECTION . FULL REHAB OF SINGLE FAMILY HOUSE . PLANS AND PERMITS REQUIRED . SCOPE OF WORK TO INCLUDE FRONT AND REAR WOOD PORCH REPLACEMENT , NORTH ATTIC DORMER FOR INTERIOR STAIRWAY , INTERIOR STIARWAY WIDTH INCREASE , INTERIOR WALL FRAMING TO INCLUDE FIRE STOPPING FOR BALLON FRAMING , REPAIR UNDERSIZED 2 BY 6 FLOOR JOIST , PLUMBING TO INCLUDE THREE FULL BATH AND KITCHEN WITH PVC DRAIN LINES AND COPPER SUPPLY LINES , ELECTRICAL POWER SERVICE AND PANEL REPLACED WITH NEW CONDUITS , BOXES , WIRING , OUTLETS , SWITCHES AND FIXTURES , VENTILATION TO INCLUDE FORCED AIR FURNACE AND ALL RELATED DUCTWORK . | 2421 N MARMORA AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BUILDING - POSTED ADDRESS NUMBERS PAINTED OVER AND NOT VISIBLE FOM STREET . | 2421 N MARMORA AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT AREAWAY MISISNG HANDRAILS AND GUARDAILS . | 2421 N MARMORA AVE | COMPLAINT | FAILED | View |
WORKING ON STOP WORK ORDER | STOP WORK ORDER POSTED AT TIME OF INSPECTION . NO PLANS OR PERMITS OBTAINED . FULL REHAB OF SINGLE FAMILY INCLUDING , WOOD PORCHES , INTERIOR WALL FRAMING , PLUMBING , VENTILATION AND ELECTRICAL . | 2421 N MARMORA AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | FRONT WOOD PORCH REMOVED , NO PLANS OR PERMITS OBTAINED . | 2421 N MARMORA AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR WOOD PORCH , DECK AND ROOF REMOVED , NO PLANS OR PERMITS OBTAINED . | 2421 N MARMORA AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIR SYSTEMS FROM BASEMENT TO FIRST FLOOR AND FIRST FLOOR TO ATTIC ONLY 30 INCHES WIDE . REQUIRES PLANS AND PERMITS FOR REPAIRS . | 2421 N MARMORA AVE | COMPLAINT | PASSED | View |
STRUCTURAL MEMBER, PIER BLOCK | INTERIOR OF BUILDING AT ATTIC , FLOOR JOIST ONLY 2 BY 6 MEMBERS , UNDERSIZED AND OVERSPANNED . BALLON FRAMED FRAMED SINGLE FAMILY BUILDING MISSING ALL FIRE STOPPING . | 2421 N MARMORA AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | STOP WORK ORDER POSTED AT TIME OF INSPECTION . FULL REHAB OF SINGLE FAMILY HOUSE . PLANS AND PERMITS REQUIRED . SCOPE OF WORK TO INCLUDE FRONT AND REAR WOOD PORCH REPLACEMENT , NORTH ATTIC DORMER FOR INTERIOR STAIRWAY , INTERIOR STIARWAY WIDTH INCREASE , INTERIOR WALL FRAMING TO INCLUDE FIRE STOPPING FOR BALLON FRAMING , REPAIR UNDERSIZED 2 BY 6 FLOOR JOIST , PLUMBING TO INCLUDE THREE FULL BATH AND KITCHEN WITH PVC DRAIN LINES AND COPPER SUPPLY LINES , ELECTRICAL POWER SERVICE AND PANEL REPLACED WITH NEW CONDUITS , BOXES , WIRING , OUTLETS , SWITCHES AND FIXTURES , VENTILATION TO INCLUDE FORCED AIR FURNACE AND ALL RELATED DUCTWORK . | 2421 N MARMORA AVE | COMPLAINT | PASSED | View |
NO POSTED ADDRESS | BUILDING - POSTED ADDRESS NUMBERS PAINTED OVER AND NOT VISIBLE FOM STREET . | 2421 N MARMORA AVE | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT AREAWAY MISISNG HANDRAILS AND GUARDAILS . | 2421 N MARMORA AVE | COMPLAINT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | 2421 N MARMORA AVE | PERMIT | PASSED | View | |
ARRANGE FOR RE-INSPECTION | NO CONDENSING UNIT INSTALLED | 2421 N MARMORA AVE | PERMIT | PASSED | View |
OPEN | 2421 N MARMORA AVE | PERMIT | PASSED | View | |
REPAIR PORCH SYSTEM | REAR WOOD PORCH , DECK AND ROOF REMOVED , NO PLANS OR PERMITS OBTAINED . | 2421 N MARMORA AVE | COMPLAINT | FAILED | View |