Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 8:56 AM
PIN: 16154270030000
Property Address: 4153 W GRENSHAW ST
City - Zip: CHICAGO - 60624
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77125
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 28 Violations
Violation Inspector Comments Address Category Status View
SOIL/WASTE,VENT PIPE MATRL BASEMENT SHOWER PVC UNDERGROUND DRAINAGE NO VENT 4153 W GRENSHAW ST COMPLAINT FAILED View
NO PERMIT WIRING BASEMENT APARTMENT 4153 W GRENSHAW ST COMPLAINT FAILED View
DEFECTIVE OUTLETS BASEMENT APARTMENT 4153 W GRENSHAW ST COMPLAINT FAILED View
DEFECTIVE LIGHTING SERVICE REPLACE ELECTRICAL PANELS NO DISCONNECT DANGEROUS AND HAZARDOUS 4153 W GRENSHAW ST COMPLAINT FAILED View
RMV PLBFIX INSTALLD W/0 PERMIT 4153 W GRENSHAW ST COMPLAINT FAILED View
INSTALL VENT PIPE FOR TRAP BASEMENT WASHROOM LAVATORY MISSING VENT 4153 W GRENSHAW ST COMPLAINT FAILED View
STOP LEAKING WATER BASEMENT KITCHEN SINK LEAKS 4153 W GRENSHAW ST COMPLAINT FAILED View
PRV FLUE FOR HOT WATER HEATER BASEMENT WATER HEATER MISSING DISCHARGE PIPE 4153 W GRENSHAW ST COMPLAINT FAILED View
REPLACE DEFECTIVE VALVE,PIPING BASEMENT WASHROOM CIELING REMOVE RUBBER HOSE ON WATER PIPING DIRECTLY ABOVE BASEMENT WATER CLOSET 4153 W GRENSHAW ST COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK 4153 W GRENSHAW ST COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC INSPECTOR REYES 312-746-8242 4153 W GRENSHAW ST COMPLAINT FAILED View
CIRCUIT ONE UNIT ONLY INSTALL PUBLIC PANEL AND METER 4153 W GRENSHAW ST COMPLAINT FAILED View
SECURE RACEWAY BASEMENT ELECTRICAL PERMIT IS REQUIRED FOR ALL WORK 4153 W GRENSHAW ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST AND WEST ELEVATIONS / PARAPET WALL - WASHED OUT MORTAR AND SPALLING BRICKS. 4153 W GRENSHAW ST COMPLAINT FAILED View
REPAIR CORNICE FRONT OF BUILDING / STONE CORNICE - 2ND FLOOR CORNICE WASHED OUT MORTAR. 4153 W GRENSHAW ST COMPLAINT FAILED View
REPAIR COPING FRONT OF BUILDING / STONE COPING - WASHED OUT MORTAR. 4153 W GRENSHAW ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT OF BUILDING / EXTERIOR STAIRSWELL - BASEMENT TO GRADE HAND RAIL MISSING. . 4153 W GRENSHAW ST COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH FRONT EXTERIOR STAIRWELL - BASEMENT TO GRADE GUARD RAILS MISSING AT GRADE. 4153 W GRENSHAW ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT PORCH - GRADE TO 1ST FLOOR LEDGER BEAM MISSING BOLTS.2X6 JOIST NAILED TO HEADERS.TOP AND BOTTOM TREAD LOOSE.GUARD RAILS AND STRINGERS NAILED TO COLUMN,HEADERS AND WALL ONLY.GUARD RAILS 32 INCHES HIGH.CENTER TREAD WEAK. PERMIT REQUIRED FOR REPAIRS TO FRONT PORCH. 4153 W GRENSHAW ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRONT EXTERIOR DOOR - 1ST DOOR DOES NOT LATCH. 4153 W GRENSHAW ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST AND WEST ELEVATIONS / PARAPET WALL - WASHED OUT MORTAR AND SPALLING BRICKS. 4153 W GRENSHAW ST COMPLAINT PASSED View
REPAIR EXTERIOR STAIR FRONT OF BUILDING / EXTERIOR STAIRSWELL - BASEMENT TO GRADE HAND RAIL MISSING. . 4153 W GRENSHAW ST COMPLAINT PASSED View
REPAIR COPING FRONT OF BUILDING / STONE COPING - WASHED OUT MORTAR. 4153 W GRENSHAW ST COMPLAINT PASSED View
REPAIR EXTERIOR DOOR FRONT EXTERIOR DOOR - 1ST DOOR DOES NOT LATCH. 4153 W GRENSHAW ST COMPLAINT PASSED View
REPAIR CORNICE FRONT OF BUILDING / STONE CORNICE - 2ND FLOOR CORNICE WASHED OUT MORTAR. 4153 W GRENSHAW ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM FRONT PORCH - GRADE TO 1ST FLOOR LEDGER BEAM MISSING BOLTS.2X6 JOIST NAILED TO HEADERS.TOP AND BOTTOM TREAD LOOSE.GUARD RAILS AND STRINGERS NAILED TO COLUMN,HEADERS AND WALL ONLY.GUARD RAILS 32 INCHES HIGH.CENTER TREAD WEAK. PERMIT REQUIRED FOR REPAIRS TO FRONT PORCH. 4153 W GRENSHAW ST COMPLAINT PASSED View
REPAIR FENCE WEST ELEVATION / STEEL FENCE - 25FTX8FT HIGH PERMIT REQUIRED FOR STEEL FENCE. 4153 W GRENSHAW ST COMPLAINT PASSED View
PROVIDE GUARD RAIL 42 IN HIGH FRONT EXTERIOR STAIRWELL - BASEMENT TO GRADE GUARD RAILS MISSING AT GRADE. 4153 W GRENSHAW ST COMPLAINT PASSED View