The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MAINTAIN EXIT SIGN ILLUMINATED | THIS VENUE HAS NUMEROUS MISSING AND INOPERABLE EXIT SIGNS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.6.1 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | THE 1ST FLOOR SUB FLOOR AND FLOOR JOISTS, ALL VIEWED FROM THE BASEMENT, SHOW AREAS OF WOOD ROT AND SPLIT FLOOR JOISTS. THERE ARE NUMEROUS AREAS WHERE TEMPORARY SHORING COLUMNS HAVE BEEN ADDED. THE ENTIRE FLOOR SYSTEM REAIRS ARE TO ADHERE TO THE STRUCTURAL ENGINEERS' REPORT THAT IS BEING ORDERED IN THIS COMOLAINT.DANGEROUS AND HAZARDOUS.SECTION 14-X-3-304.4 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSED WIRING WAS OBSERVED IN THE BASEMENT AND 1ST FLOORS OF THIS VENUE AT SEVERAL LOCATIONS. DANGEROUS AND HAZARDOUS.SECTION 14X-7-703 / 705. | 3048 W 63RD ST | COMPLAINT | FAILED | View |
POST APPROVED OCCUPANCY CARD | THIS UNLICENSED EVENT SPACE HAS NO APPROVED OCCUPANCY.SECTION 14A-8-802 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | THE BASEMENT GAS FURNACE AND 2 GAS WATER HEATERS DO NOT HAVE FIRE RESISTANT ENCLOSURES.DANGEROUS AND HAZARDOUS.SECTION 14B-5-509 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | THIS FORMER RESTAURANT IS CURRENTLY WITHOUT ANY LICENSES TO OPERATE AT ANY CAPACITY. THIS SPACE IS CURRENTLY BEING OPERATED AS AN ONGOING, ILLEGAL PPA EVENT SPACE. THERE ARE NO PLANS, PERMITS, ZONING OR PPA APPLICATIONS ON FILE TO BRING THIS VENUE INTO COMPLIANCE. THERE ARE 6 UNLICENSED FOOD TRUCKS ON THIS SITE AS WELL. A REFERRAL TO THE DEPARTMENT OF REVENUE IS BEING MADE TO ADDRESS ANY SHORTFALL IN PAYMENT OF SALES TAXES.ALSO, THERE ARE NO PLANS OR PERMITS ON FILE FOR THE INTERIOR PLUMBING AND ELECTRICAL WORK PERFORMED IN THE 1ST FLOOR EVENT SPACE AND THE BASEMENT. THERE HAS BEEN ELECTRICAL / PLUMBING PIPING / WIRING WORK WITH ASSOCIATED FIXTURES INSTALLED WITHOUT PERMIT. ALSO, AT THE REAR 2CD FLOOR AREA, AN APARTMENT HAS BEEN INSTALLED WITHOUT PLANS, PERMITS OR ZONING AUTHORIZATION. THIS APARTMENT WAS OCCUPIED AT THE TIME OF THIS INSPECTION. ALSO, THE ARE NO PLANS / PERMITS ON FILE FOR THE CONSTRUCTION OF A VERY LARGE CAR PORT STRUCTURE AT THE REAR.THE VENUE WAS VACATED. THE APARTMENT WAS VACATED. BOTH DOB AND BACP ISSUED CLOSURE ORDERS.SECTION 14A=4=401.1 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE 2CD FLOOR REAR APARTMENT INSTALLED WITHOUT PLANS, PERMITS OR ZONING CERTIFICATE.SECTION 14A-4-401.1 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | AFTER CONSTRUCTING THE 2 BASEMENT ENCLOSURE FOR THE WATER HEATERS AND FURNACE, A CLASS B FIRE DOOR IS TO BE INSTALLED.SECTION 14B-7-716 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | THIS STRUCTURAL REPORT IS TO EXAMINE THE FLOOR SYSTEM ABOVE THE BASEMENT FOR THE 1ST FLOOR. THERE ARE DEGRADED FLOOR JOISTS AND NUMEROUS TEMPORARY COLUMNS IN PLACE TO SUPPORT THIS FLOOR SYSTEM.ALSO, A LARGE GARAGE / CAR PORT WAS CONSTRUCTED WITHOUT PLANS / PERMITS. THIS STRUCTURE IS TO BE EXAMINED FOR BUILD QUALITY AND DESIGN. THERE ARE NO COLIMN FOOTINGS AND THE ROOF RAFTERS APPEAR TO BE UNDERSIZED.SECTION 14X-1-104.1 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | THERE ARE SEVERAL AREAS IN THE BASEMENT WHERE THE DRAIN STACKS ARE LEAKING RAW HUMAN WASTE. UNSANITARY CONDITIONS. DANGEROUS AND HAZARDOUS.SECTION 14X-9-902.1 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN ASSEMBLY | THERE ARE NO SMOKE DETECTORS IN THIS UNLICENSED VENUE.DANGEROUS AND HAZARDOUS.SECTION 14X5-504.9 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | THE REAR EXIT PATHWAY WHERE THE LARGE CAT PORT ROOF STRUCTURE IS LOCATED IS COMPLETELY OBSTRUCTED BY A LARGE TRUCK AND A PADLOCKED FENCE AND GATE. DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.1.2 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | THERE ARE NO SMOKE DETECTORS IN THIS UNLICENSED EVENT SPACE.DANGEROUS AND HAZARDOUS.SECTION 14-5-504.8 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
FLAM LIQ TANK FRONTAGE CONSENT | THERE ARE NUMEROUS PROPANE TANKS SCATTERED THROUGHOUT THIS VENUE, SOME OF WHICH ARE IN THE KITCHEN NEAR OPEN FLAME COOK TOPS.DANGEROUS AND HAZARDOUS.SECTION 4-108-050 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | THIS REAR GARAGE / CAR PORT STRUCTURE HAS NO COLUMN FOOTINGS. THE ROOF RAFTERS ARE UNDER SIZED 2X4'S. THIS STRUCTURE WAS BUILT WITHOUT PLANS / PERMIT.SECTION 14X-3-303.1.1 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | THERE IS VERY LITTLE DEDICATED EXIT ILLUMINATION AT / NEAR ANY OF THE 4 EXIT DOORS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-506.1.1 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | 1 OF 2 FRONT EXIT DOORS HAS A KEY LOCK. IN TOTAL, 2 OF 4 EXIT DOORS REQUIRE A KEY TO EGRESS THIS BUILDING AND NO KEYS WERE ON SITE. DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.1.2.2 | 3048 W 63RD ST | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | THE ENTIRE BASEMENT CEILING IS OPEN / EXPOSED WOOD JOISTS AND SUB FLOORING FOR THE 1ST FLOOR. THERE IS NO FIRE SEPARATION WHAT SO EVER.DANGEROUS AND HAZARDOUS.SECTION 14B-6-605.4 | 3048 W 63RD ST | COMPLAINT | FAILED | View |