Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | AT THE REAR, 1 STORY SECTION OF THIS PROPERTY THERE ARE STEP FRACTURES IN THE BRICKWORK (WEST ELEVATION). THERE ARE A FEW LOOSE BRICKS ABOVE THE SIDE DOOR AS WELL. PERMIT REQUIRED FOR REPAIRS. | 3925 W CHICAGO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR MASONRY WALL WEST AND SOUTH ELEVATION WASHED OUT MORTAR JOINTS WEST ELEVATION ABOVE REAR EGRESS FACADE IS SHIFTING 14X-3-303.1.1 | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
CHIMNEY | CHIMNEY WASHED OUT MORTAR JOINTS 14X-3-303.1.1 | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | CEILING AT 1ST FLOOR COMMERCIAL SPACE SECTION WATER DAMAGE AND MOLD LIKE SUBSTANCE EAST ELEVATION 14X-3-304.3 | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR EGRESS 1ST FLOOR BLOCKED BY SHOPPING CART AND GARBAGE CAN 14X-5-505.1.2 D&H | 3925 W CHICAGO AVE | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | THERE IS A BLACK ORGANIC MOLD LIKE SUBSTANCE ON 1ST FLOOR CEILING BASEMENT,AND REAR ENCLOSED PORCH 14X-1-103 | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
UNDERSIDE STAIR 1HR FIRE RES | MISSING FIRE SEPARATION BELOW WOODEN STAIRS AT BASEMENT 14X-5-505.9.6 D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR EGRESS 1ST FLOOR BLOCKED BY SHOPPING CART AND GARBAGE CAN 14X-5-505.1.2 D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR AT BASEMENT 14X-5-504.9 D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | HAND SINK INSTALLED BEHIND COUNTER WITH PERMIT | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
STOP LEAKING WATER | WATER LEAKING AT FOUNDATION IN BASEMENT | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
PROVIDE | NO HOT WATER OR COLD WATER AT HAND SINK AT REAR OF STORE 8-29.607.1 | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | PVC PIPING AT BATHROOM LAVATORY DRAIN AT REAR OF STORE D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | PVC SADDLE INSTALLED ON 4' CAST IRON WASTE STACK IN CENTER OF BASEMENT D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
PRV FLOOR DRAIN WITH METAL STR | NO FLOOR DRAIN COVERS THROUGHOUT BASEMENT | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
RMV DFT PIPE,FITTING,FIXTURE | NON SHEER BANDS RUBBER FERNCO COUPLINGS INSTALLED ON OVERHEAD PVC LOCATED IN BASEMENT | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
EXPOSED WIRING | REMOVE EXPOSED WIRING AND COVER OPEN BOXES WITH EXPOSED WIRING IN REAR OF BUILDING DEEMED D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
SUPPORT OUTLET AND BOX | SUPPORT OUTLET PIPE AND BOXES FRONT AREA OF STORE BEHIND COUNTER | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
SMOKE & CARBON DETECTORS | INSTALL S/C DETECTORS IN BASEMENT | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
INSTALL GFCI'S | INSTALL GFCI NEAR SINK IN FRONT OF STORE BY SINK BEHIND THE COUNTER | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
SUPPORT OUTLET AND BOX | SUPPORT 100 AMP PANEL & PIPE IN REAR | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
SUPPORT FIXTURES | REPAIR REPLACE EXTERIOR LIGHT FIXTURE | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
REPAIR**************** | EXTERIOR CAMERA BOXES NEED TO BE WEATHER PROOF BOXES | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
PROPER SIZE GRD ELECTRODE COND | OBTAIN ELECTRICAL PERMIT | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
OPEN | 3925 W CHICAGO AVE | PERMIT | PASSED | View | |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- SECOND FLOOR APARTMENT,NO RESPONSE,UNVERIFIED DETECTORS,AND CONDITIONS. | 3925 W CHICAGO AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING-NO OWNER'S ID SIGN POSTED. | 3925 W CHICAGO AVE | COMPLAINT | FAILED | View |
PARAPET | EAST ELEVATION-PARAPET WALL,SPALLED BRICKS AND WASHED OUT MORTAR. | 3925 W CHICAGO AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S I.D SIGN POSTED. | 3925 W CHICAGO AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | BASEMENT AREA (2) JOISTS NEXT TO CENTRAL PLUMBING STACK EAST ELEVATION ROTTED AT POCKET (5) TEMPORARY 4X6 COLUMNS AT WEST ELEVATION NO VISIBLE FOOTINGS 14X-3-303.1.21 | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
PANEL SCHEDULES | PANEL SCHEDULE FOR 100 AMP PANEL THATS NOT SUPPORTED | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
PRV FLUE FOR HOT WATER HEATER | HOT WATER TANK FLUE PIPE IS NOT CONNECTED LOCATED IN BASEMENT D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
MICE/RODENTS | RODENT DROPPINGS OBSERVED A BASEMENT 14X-102.2.4 | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED COMPLAINT OF NO LIGHTS IN HALLWAY AND METAL DOOR WELDED SHUT. | 3925 W CHICAGO AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PLUMBING PERMIT FOR PLUMBING WORK TO BE PERFORMED | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
STOP LEAKING WATER | LEAKING WATER AT CEILING IN STORE | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
STOP LEAKING WATER | WATER LEAK AT THE BASE OF WASTE STACK IN CENTER OF BASEMENT D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
REMV OBSTR FROM DRAINAGE SYSTM | HAND SINK IS NOT DRAINING PROPERLY AT THE REAR OF STORE | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | REAR INTERIOR STAIRS FROM 1ST FLOOR TO 2ND FLOOR LOOSE TREADS 14X-3-304.4 | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
LICENSED BONDED PLMBG CONTRCTR | EMPLOY LICENSED AND BONDED PLUMBING CONTRACTOR FOR PLUMBING WORK TO BE PERFORMED TO ADDRESS PLUMBING VIOLATIONS | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BASEMENT EXPOSED WOODEN JOISTS THERE IS TOTAL LACK OF FIRE SEPARATION AT CEILING 14B-6-605.4 D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | PVC INSTALLED IN BASEMENT FOR HAND SINK INSTALLATION D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
FIRE EXTNGSHR RECHARGE & TAG | FIRE EXTINGUISHERS NOT TAGGED 14X-5-504.5 D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
REPAIR BATTERY LIGHT | RESTORE EMERGENCY LIGHTING BATTERY PACKS | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | 2' PVC INSTALLED THROUGHOUT BASEMENT | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR ENCLOSED PORCH MISSING FIRE SEPARATION 14X-3-303.1.1 D&H | 3925 W CHICAGO AVE | COMPLAINT | PASSED | View |