Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR INTERIOR WALLS/CEILING | 2ND FLOOR FRONT INTERIOR STAIRS - LARGE GAPS IN WEST WALL ALLOWING AIR AND WATER INTO INTERIOR STAIRWELL. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION, STAIR SYSTEM FROM GRADE TO 2ND FLOOR - 4X4 COLUMNS SET ON CONCRETE SLAB, FOUNDATIONS UNKNOWN. 4X4 COLUMNS SUPPORT SINGLE RUN OF STAIRS FOR 14 FEET 9 3/4 INCHES. TREADS 7 1/4 INCHES WIDE, RISERS 7 3/4 INCHES HIGH. RAILINGS WEAK, LADDER TYPE AND ONLY 35 1/2 INCHES HIGH. INSIDE STRINGER NO VISIBLE SIGNS OF ANCHORS TO WALL. ENTIRE STAIR SYSTEM WEAK. DANGEROUS AND HAZARDOUS. PLANS AND PERMIT REQUIRED TO REBUILD STAIR SYSTEM.EAST ELEVATION, STAIRS FROM GRADE TO 1ST FLOOR. - 4X4 COLUMNS SET ON CONCRETE SLAB, FOUNDATIONS UNKNOWN. OUTSIDE STRINGER CRACKED. RAILINGS LADDER TYPE, LOOSE AND ONLY 35 1/2 INCHES HIGH. NORTH SIDE RIM JOIST OVER NOTCHED. COLUMN SPLICED 12 INCHES FROM GROUND, CONNECTION FAILING. PERMIT REQUIRED FOR REPAIRS. SOUTH ELEVATION, STAIRS FROM GRADE TO 1ST FLOOR - RAILINGS WEAK AND LOOSE. SOUTH ELEVATION, STAIRS FROM GRADE TO BASEMENT - MISSING RAILINGS. - FALL HAZARD. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EAST ELEVATION, 1ST FLOOR - DOOR DELAMINATING. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR FRONT INTERIOR STAIR - MISSING SMOKE DETECTOR AT TOP OF STAIRWELL. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST FLOOR UNIT 1F AND 2ND FLOOR UNIT 2R - SMOKE DETECTOR OUT OF SERVICE. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | 1ST FLOOR UNIT 1F - TUB PLUMBING FIXTURE BROKEN AND MISSING PARTS. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
INSTALL DEAD BOLT LOCK | 2ND FLOOR UNTI 2R - REAR DOOR DEAD BOLT LOCK OUT OF SERVICE. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | SOUTH ELEVATION, REAR 2 STORY INTERIOR STAIR SYSTEM - 1ST FLOOR DECK WEAK AND BUCKLING. RAILINGS WEAK AND OF LADDER TYPE. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | 1ST FLOOR UNIT 1R - KITCHEN SINK LEAKING WITH BLACK STAINS AND MILDEW IN MULTIPLE KITCHEN CABINETS. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | 1ST FLOOR UNIT 1R - MICE HOLES IN KITCHEN AND BREDROOMS. DROPPINGS IN KITCHEN. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
REMOVE | 1ST FLOOR UNIT 1R - BEDROOM - REMOVE OLD CARPET TACK STRIPS IN BEDROOM. (DANGEROUS TO CHILDREN) | 1811 N LONG AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | 1ST FLOOR UNIT 1R - KITCHEN FURNACE - SWITCH BOX OPEN WITH EXPOSED WIRES. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION, STAIR SYSTEM FROM GRADE TO 2ND FLOOR - 4X4 COLUMNS SET ON CONCRETE SLAB, FOUNDATIONS UNKNOWN. 4X4 COLUMNS SUPPORT SINGLE RUN OF STAIRS FOR 14 FEET 9 3/4 INCHES. TREADS 7 1/4 INCHES WIDE, RISERS 7 3/4 INCHES HIGH. RAILINGS WEAK, LADDER TYPE AND ONLY 35 1/2 INCHES HIGH. INSIDE STRINGER NO VISIBLE SIGNS OF ANCHORS TO WALL. ENTIRE STAIR SYSTEM WEAK. DANGEROUS AND HAZARDOUS. PLANS AND PERMIT REQUIRED TO REBUILD STAIR SYSTEM.EAST ELEVATION, STAIRS FROM GRADE TO 1ST FLOOR. - 4X4 COLUMNS SET ON CONCRETE SLAB, FOUNDATIONS UNKNOWN. OUTSIDE STRINGER CRACKED. RAILINGS LADDER TYPE, LOOSE AND ONLY 35 1/2 INCHES HIGH. NORTH SIDE RIM JOIST OVER NOTCHED. COLUMN SPLICED 12 INCHES FROM GROUND, CONNECTION FAILING. PERMIT REQUIRED FOR REPAIRS. SOUTH ELEVATION, STAIRS FROM GRADE TO 1ST FLOOR - RAILINGS WEAK AND LOOSE. SOUTH ELEVATION, STAIRS FROM GRADE TO BASEMENT - MISSING RAILINGS. - FALL HAZARD. | 1811 N LONG AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | EAST ELEVATION, 1ST FLOOR - DOOR DELAMINATING. | 1811 N LONG AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR FRONT INTERIOR STAIR - MISSING SMOKE DETECTOR AT TOP OF STAIRWELL. | 1811 N LONG AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | 2ND FLOOR FRONT INTERIOR STAIRS - LARGE GAPS IN WEST WALL ALLOWING AIR AND WATER INTO INTERIOR STAIRWELL. | 1811 N LONG AVE | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST FLOOR UNIT 1F AND 2ND FLOOR UNIT 2R - SMOKE DETECTOR OUT OF SERVICE. | 1811 N LONG AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE FAUCET | 1ST FLOOR UNIT 1F - TUB PLUMBING FIXTURE BROKEN AND MISSING PARTS. | 1811 N LONG AVE | COMPLAINT | PASSED | View |
INSTALL DEAD BOLT LOCK | 2ND FLOOR UNTI 2R - REAR DOOR DEAD BOLT LOCK OUT OF SERVICE. | 1811 N LONG AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | SOUTH ELEVATION, REAR 2 STORY INTERIOR STAIR SYSTEM - 1ST FLOOR DECK WEAK AND BUCKLING. RAILINGS WEAK AND OF LADDER TYPE. | 1811 N LONG AVE | COMPLAINT | PASSED | View |
EXPOSED WIRING | 1ST FLOOR UNIT 1R - KITCHEN FURNACE - SWITCH BOX OPEN WITH EXPOSED WIRES. | 1811 N LONG AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING/ OWNERS ID SIGN- MISSING. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION/ EXTERIOR WALL- BULGING SECTIONS. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | NORTH, AND WEST ELEVATIONS/ WINDOW FRAMES- ROTTING SECTIONS. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | ALL ELEVATIONS/ EAVES- ROTTING, WITH PEELING PAINT. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- ENTRY REFUSED, UNVERIFIED DETECTORS, CONDITIONS, LAYOUT, AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 1811 N LONG AVE | COMPLAINT | FAILED | View |
REMOVE | 1ST FLOOR UNIT 1R - BEDROOM - REMOVE OLD CARPET TACK STRIPS IN BEDROOM. (DANGEROUS TO CHILDREN) | 1811 N LONG AVE | COMPLAINT | PASSED | View |
DWELLING CLEAN AND SANITARY | 1ST FLOOR UNIT 1R - KITCHEN SINK LEAKING WITH BLACK STAINS AND MILDEW IN MULTIPLE KITCHEN CABINETS. | 1811 N LONG AVE | COMPLAINT | PASSED | View |
MICE/RODENTS | 1ST FLOOR UNIT 1R - MICE HOLES IN KITCHEN AND BREDROOMS. DROPPINGS IN KITCHEN. | 1811 N LONG AVE | COMPLAINT | PASSED | View |