Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR OR REPLACE | SOUTH ELEVATION DOWNSPOUT DISCONNECTED (18-29-1101-2.1) | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH IMPROPER CONCRETE BLOCK FOUNDATIONS BEAM COLUMN CONNECTIONS MISSING BOLTS GUARDRAILS AND HANDRAILS MISSING ANGLE CONNECTORS OBTAIN PLANS AND PERMIT FOR PORCH REPAIRS | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | 1ST AND 2ND FLOOR LEVEL APARTMENTS, EVIDENCE OF MICE | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
FLUE PIPE CLEARANCE 6"X | 1ST LEVEL APARTMENT FURNACE AND 2ND FLURNACE AND 2ND LEVEL APARTMENT FURNACE MISSING THIMBLE | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
FOUNDATION FOR FURNACE/BOILER | ATTIC FURNACE MISSING FOUNDATION | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | 1ST LEVEL APARTMENT FURANCE ROOM, DRYWALL ON ONE SIDE ONLY | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
GROUNDING RECEPTACLES | REPLACE OUTLET IN LAUNDRY ROOM WITH GFCI OUTLET 18-27-210.50 | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
DEFECTIVE POWER SERVICE | LABEL PANELS,LAUNDRY ROOM STAIRWELL ON TENANTS PANEL 18-27-230.2 | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
REMOVE EXPOSED CABLE | REMOVE ROMEX 1ST FLOOR LIVING ROOM 18-27-336.3 | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
DEFECTIVE FEEDER | REPAIR DEFECTIVE WIRING,BULBS CONTINUOUSLY BLOWING 18-27-215.2 | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | 18-27-560.7 ILLUMINATE FRONT ENTRY WAY | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | 18-27-210.25 INSTALL PANEL AND METER FOR COMMON AREA CIRCUITS PANEL AND METER INSTALLED COMMON AREA CIRCUIT NEVER WIRED | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
CIRCUIT ONE UNIT ONLY | 18-27-560.23 USE BRANCH CIRCUIT CONDUCTORS FOR ONE UNIT ONLY LAUNDRY ROOM AND STAIRWAY WIRED TO 1ST FLOOR APARTMENT | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |
APPLIANCE INSIGHT DISCONNECT | 18-27-422.30 INSTALL DISCONNECT SWITCH FOR 1ST FLOOR FURNACE | 8723 S SAGINAW AVE | COMPLAINT | FAILED | View |