Chicago Building Violations Data: 31 Violations
Violation Inspector Comments Address Category Status View
REPL DEFECTIVE BATHROOM FLOOR 2ND FLOOR, KITCHEN FLOOR: BROKEN TILE, 1ST KITCHEN 5115 S CAMPBELL AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS LOOSE RECEPTACLE COVER, 2ND FLOOR, KITCHEN COUNTER; DEFECTIVE RECEPATACLES, 2ND FLOOR, DINING ROOM; 1ST FLOOR: FAN WOBBLING; IMPROPER LIGHT SWITCH, 2ND FLOOR, CENTER BEDROOM 5115 S CAMPBELL AVE COMPLAINT FAILED View
EXPOSED WIRING LIGHT HANGING BY WIRE, 1ST BACK BEDROOM 5115 S CAMPBELL AVE COMPLAINT FAILED View
REPAIR DOOR, INT. DOOR BROKEN, 2ND FLOOR, ATTIC BEDROOM, 1ST BEDROOM THROUGHOUT 5115 S CAMPBELL AVE COMPLAINT FAILED View
CARPETING TORN CARPET, 2ND FLOOR TO ATTIC 5115 S CAMPBELL AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS BROKEN WINDOW, 2ND FLOOR KITCHEN, SOUTH WINDOW, 2ND FRONT, 1ST FRONT 5115 S CAMPBELL AVE COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT 1ST FLOOR: BATHROOM MOLD 5115 S CAMPBELL AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR EXTERIOR STAIRS, FRONT RAIL RUSTED & BROKEN, STRINGER CRACKED AND BROKEN, STRINGERS NOT BOLTED, DECKING ROTTED 5115 S CAMPBELL AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE 1ST FRONT: MISSING VIEWING DEVICE 5115 S CAMPBELL AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR DOOR, 1ST FRONT: DELAMINATED 5115 S CAMPBELL AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH: STRINGER NOT BOLTED, FOUNDATION UNKNOWN, BEAMS NOT BOLTED AND SPLIT, LEDGER NAILED, STAIRS HAVE PITCH IN EXCESS; OBTAIN PERMIT 5115 S CAMPBELL AVE COMPLAINT FAILED View
REPAIR EAVES FRONT SOFFIT: ROTTED 5115 S CAMPBELL AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# OWNER'S I.D. SIGN-NOT POSTED. 5115 S CAMPBELL AVE COMPLAINT FAILED View
MAINTAIN WINDOW WINDOW OPENINGS-CONCEALED WITH PLYWOOD. 5115 S CAMPBELL AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR STEEL FENCING (7 FEET HEIGHT)-ERECTED WITHOUT A PERMIT. 5115 S CAMPBELL AVE COMPLAINT FAILED View
CHIMNEY EAST CHIMNEY-HOLE IN MASONRY. 5115 S CAMPBELL AVE COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR FRONT GATES-DOUBLE KEYED LOCKS. 5115 S CAMPBELL AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE ACCUMULATION OF TRASH; JUNK AND BROKEN CONCRETE. 5115 S CAMPBELL AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR REAR STAIRS (1-STORY / 8 FEET 9 INCH HEIGHT; ERECTED WITHOUT PLANS / PERMIT) WITH ATTACHED PLATFORM ( APPROXIMATELY 240 SQUARE FEET)-4X6 COLUMNS ARE SET ON TOP OF THE SERVICE WALK; FOUNDATION STATUS IS UNKNOWN. LEDGER IS ONLY NAILED INTO AND PULLING AWAY FROM THE EXTERIOR WALL CONNECTION. EDGE BEAMS ARE ONLY NAILED INTO THE COLUMN CONNECTIONS; EAST BEAM IS ROTTED THRU. RIM JOISTS ARE ONLY NAILED INTO THE COLUMN AND GRAIN OF LEDGER CONNECTIONS. PLATFORM IS PITCHED DOWNWARD TOWARD EAST. UNDERSIZED 2X4 JOIST HANGERS UTILIZED FOR 2X8 DECK JOISTS. STRINGERS ARE ONLY NAILED INTO THE COLUMN / EDGE BEAM CONNECTIONS. FLIGHT IS PITCHED DOWNWARD TOWARD WEST. WORN TREADS AND DECKBOARDS; NAILS PROTRUDING OUT. HANDRAILS ARE ONLY NAILED INTO THE COLUMN CONNECTIONS. GUARDRAILS ARE ONLY TOE NAILED INTO AND PULLING FROM THE COLUMN CONNECTIONS; GUARDRAILS SHIFT WERE THE SPAN IS GREATER THAN 4 FEET; MISSING BALUSTERS. SUBMIT PLANS / OBTAIN PERMIT FOR STAIR SYSTEM REPLACEMENT. 5115 S CAMPBELL AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE-UNVERIFIED COMPLAINT OF: SR#121196278-APARTMENT WAS CREATED IN THE ATTIC. 5115 S CAMPBELL AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING,I D SIGN MISSING OWNERS ADDRESS. 5115 S CAMPBELL AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR NORTH ELEVATION,7' METAL FENCE BUILT,NO PERMIT ON FILE. 5115 S CAMPBELL AVE COMPLAINT FAILED View
CHIMNEY NORTH ELEVATION,CHIMNEY,HOLE IN MASONRY BLOCK. 5115 S CAMPBELL AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE REAR YARD,BLUE TARP,OLD HOT TUB,OLD CAR TIRES,PLASTIC BAGS,LADDERS, SCRAP ALUMINUM. 5115 S CAMPBELL AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE REAR YARD,ABANDON AUTO.(SECT.7-28-060). 5115 S CAMPBELL AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM WEST ELEVATION,FRONT EXTERIOR PORCH GRADE TO 2ND FLOOR,4X6 COLUMNS ARE SET ON CONCRETE, FOUNDATION STATUS UNKNOWN,LEDGER BOARD IS FACE NAILED ONLY,4X6 COLUMNS ARE ROTTED,EDGE BEAMS ARE ONLY NAILED TO LEDGER AND COLUMN CONNECTIONS,HEADER BEAM IS TOE NAILED ONLY,STRINGERS ARE FRACTURED AND TOE SCREWED ONLY,STAIR SYSTEM SWAYS SIDE TO SIDE UNDER LOAD,TREADS AND DECKING BOARDS ARE LOOSE AND WEAK.PLANS AND PERMIT REQUIRED . 5115 S CAMPBELL AVE COMPLAINT FAILED View
REPLACE D&H PORCH EAST ELEVATION,REAR EXTERIOR PORCH GRADE TO 2ND FLOOR,4X6 COLUMNS ARE SET ON SIDEWALK,FOUNDATION STATUS UNKNOWN,LEDGER BOARD IS FACE NAILED ONLY AND PULLING AWAY FROM BUILDING,EDGE BEAMS ARE FACE NAILED TO CONNECTIONS,EAST BEAM IS ROTTED THRU,MISSING SECTION,JOISTS ARE 2X8 SECURED WITH 2X4 HANGERS ONLY,STRINGERS ARE FACE NAILED ONLY,STAIRS ARE PITCHING OUT OF LEVEL,TREADS AND DECK BOARDS ARE WORN WITH NAILS POPPING,DECKING IS PITCHING OUT OF LEVEL,RAILS ARE TOE NAILED ONLY,LOOSE AND PULLING,MISSING PICKETS.PLANS AND PERMIT REQUIRED FOR DANGEROUS PORCH. 5115 S CAMPBELL AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR EXTERIOR ALTERATIONS OF EXISTING TWO STORY FRAME CONSTRUCTION MULTI UNIT RESIDENTIAL BUILDING INCLUDING BUT NOT LIMITED TO 1. 7' ROLLING METAL GATE AT NORTH ELEVATION 2. 25' WIDE X 30' LONG ROOF STRUCTURE IN REAR YARD DIRECTLY ADJACENT TO DETACHED GARAGE 3. TWO STORY FRAME CONSTRUCTION EXITERIOR STAIR WITH ROOF COVERING AT EAST ELEVATION OF EXISTING TWO STORY BUILDING ENTIRE STRUCTURE CLADDED WITH CLEAR CORRUGATED PLASTIC SUBMIT PLANS AND OBTAIN PERMITS AS REQUIRED 5115 S CAMPBELL AVE COMPLAINT FAILED View
BLANK-TEXT MUST CITE CODE SECT PERMIT FEE AND PENALTY TO BE ASSESSED FOR WORK COMPLETED WITHOUT A BUILDING PERMIT 14A-3-306-1 14A-4-411-1 5115 S CAMPBELL AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS STORM DOOR AT 2ND REAR: TORN PANEL, AND MISSING SCREEN 5115 S CAMPBELL AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT PORCH (1-STORY / 9 FEET 2 INCH HEIGHT)-ROTTED 4X6 COLUMNS ARE SET ON TOP OF CONCRETE BASES; FOUNDATION STATUS IS UNKNOWN. LEDGER IS ONLY NAILED INTO THE BUILDING CONNECTION. EDGE BEAMS ARE ONLY NAILED INTO THE GRAIN OF LEDGER AND COLUMN CONNECTIONS. HEADER BEAM IS ONLY TOE NAILED INTO THE COLUMN CONNECTIONS. WORN, FRACTURED STRINGERS ARE ONLY SCREWED INTO THE COLUMN CONNECTIONS. FLIGHT SHIFTS LATERALLY UPON LOAD. WORN, LOOSE TREADS AND DECK BOARDS. SUBMIT PLANS / OBTAIN PERMIT FOR PORCH REPLACEMENT. 5115 S CAMPBELL AVE COMPLAINT FAILED View