The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | 2 STORY OPEN REAR WOOD PORCH; ALL CONNECTIONS ARE MADE BY NAILS ONLY AT RAILS, STRINGERS, RIM BOARDS, LOOKOUTS, JOIST. BEAM TO COLUMNS CONNECTION IS FIRECUT AND LIGHT GAGE METAL PLATE. RAILS ARE 36'' HIGH. 2X8 JOIST SPAN 13'. SUBMIT PLANS AND OBTAIN PERMIT. | 3820 W ADAMS ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BASEMENT WINDOWS ALL BOARDED. | 3820 W ADAMS ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | DEBRIS SCATTERED AT SIDE AND REAR YARD. | 3820 W ADAMS ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. | 3820 W ADAMS ST | COMPLAINT | FAILED | View |
REPAIR FENCE | NORTH FENCE, MISSING GATE. | 3820 W ADAMS ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR OPEN 2 STORY PORCH, HAS OVER-SPANNED 6X6" BEAMS AND 2X8" JOISTS (SPAN IS 7'-5" AND 11'-6") GUARDRAILS ARE TO LOW (36"), DEFLECT UNDER PRESSURE, MISSING TOP SIDE RAIL AND 4X4" POSTS EVERY 4'-0", END POST TO WALL FASTENED WITH NAILS ONLY, RIM JOISTS TO WALL AND TO COLUMNS, STRINGERS TO JOISTS AND TO RAIL POSTS ARE FASTENED WITH NAIL ONLY, COLUMN TO BEAM CONNECTIONS, FASTENED WITH LIGHT GAGE METAL CONNECTOR. PLAN AND PERMIT REQUIRED TO REPAIR OR REPLACE PORCH. | 3820 W ADAMS ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | SOUTH COMMON DOOR- LOOSE DOORKNOB. | 3820 W ADAMS ST | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | NORTH WEST DOWNSPOUT, MISSING BOTTOM SECTION. | 3820 W ADAMS ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH AND WEST ELEVATIONS - FRACTURES WITH OPEN JOINTS AT VARIOUS LOCATIONS | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | CHIMNEY - MISSING CAP | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
REPAIR COPING | SOUTH, EAST AND WEST ELEVATIONS -LOOSE COPINGS WITH OPEN JOINTS | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT - WATER DAMAGED CEILINGS AND WALLS THRU-OUT | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | REAR YARD - GARBAGE THRU-OUT , CONDUSIVE TO RAT HARBORAGE. | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT - SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | BASEMENT - REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
CHIMNEY | CHIMNEY - FRACTURES , LOOSE BRICKS AND MORTAR | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
RATS | INTERIOR OF BUILDING - RATS | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
REPAIR FLOOR | BASEMENT - LOOSE AND BROKEN TILES ,HOLES AT SUBFLOORING THRU-OUT. | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | FRONT BASEMENT STAIRS- UNEVEN CONCRETE RISERS, MISSING HANDRAIL | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
REPAIR DOOR, INT. | BASEMENT - DAMAGED AND BROKEN ROOM DOORS AND FRAMES | 3820 W ADAMS ST | COMPLAINT | PASSED | View |
RATS | RATS ON PREMISE. | 3820 W ADAMS ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH GRADE TO BASEMENT, GUARDRAILS ARE TO LOW, 31". | 3820 W ADAMS ST | COMPLAINT | FAILED | View |