Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PRV HIGH SIDE | FOR ONE COPELAND 1.5 HP. COMPRESSOR SERVING REACH -IN COOLER LOCATED ON REAR GRADE. | 7101 S ASHLAND AVE | PERIODIC | FAILED | View |
PRV HIGH SIDE | FOR ONE COPELAND 1.5 HP. COMPRESSOR SERVING REACH -IN COOLER LOCATED ON REAR GRADE. | 7101 S ASHLAND AVE | PERIODIC | PASSED | View |
SEE INSPECTOR COMMENTS | CLEAROUT ELECTRICAL ROOM MAINTAIN CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT (18.27.110.26) | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
INSTALL AREA IN BACK ROOM NEAR SINK (18.27.110.8) AND EXTERIOR NORTH ELEVATION | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View | |
UNAPPROVED EM | REMOVE WATERPROVED EMERGENCY LIGHTING EQUIPMENT AND INSTALL CHICAGO APPROVED BATTERY BACK UP EXITS AND BATTERY PACKS | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
INSTALL COVERS | INSTALL COVER TO EXTERIOR THROUGH AT EAST ELEVATION | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE PUC UNDER 3-COMPARTMENT SINK & VENT PIPING | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
REPAIR DEFECTIVE FITTINGS | DISCONNECTED VENT AT 3-COMPARTMENT SINK | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
PRV CNTRL VALVE WATER SUPPLY | PROVIDE A GATE VALVE AT INNER SIDE OF WATER HEATER | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | EXTEND RELIEF VALVE DISCHARGE PIPE AT GAS FIRED WATER HEATER | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | PUC SUPPLIES AT WATER CLOSET & LAVATORY EMPLOYEES TOILETROOM | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
OBTAIN PERMIT FOR PLUMBING | TO CORRECT ALL PLUMBING VIOLATIONS | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | A LICENSED & BONDED PLUMBING CONTRACTOR IS REQUIRED | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
REPAIR FENCE | STEEL PICKET IS RUSTED SCRAPE & PAINT, SOUTH FENCE HAS TWISTED PICKETS | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | SOUTH METAL WALL IS RUSTING SCRAPE & PAINT | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | MISSING C.O. DETECTOR | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | BROKEN SIDEWALK RAISED TRIP HAZARD NORTH NEAR VACUUM | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
PROVIDE GEC TO COLD WATER MAIN WITHIN 5FT OF BUIDING ENTRY . 14E-2-250.68 C1 | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View | |
LISTED FOR USE TEMP & LOCATION | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View | |
SEAL DRAIN OPENING UNUSD FIXTR | ABANDONED LAVATORIES THROUGHOUT FULL OF STOCK. DANGEROUS AND HZARDOUS. | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | STRUCTURAL ENGINEERS REPORT REQUIRED TO DETERMINE ADAQUATE REPAIRS REQUIRED TO RECTIFY FAILING ROOF RAFTER. | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | ROOF RAFTER SEPERATING AT NORTH/EAST SECTION AT PROPERTY. | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR DOOR MARKED EXIT PAD LOCKED FROM INSIDE PROPERTY AT TIME OF INSPECTION. | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | EXPIRED FIRE EXTINGUISHER AT PROPERTY. | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View | |
SUPPLEMENTAL GROUND | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View | |
MOTOR INSIGHT DISCONNECT | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View | |
NEED ELECTRICAL PERMIT TO CORRECT VIOLATIONS. 14E-4-404.6 | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View | |
CORD WIRED EQUIPMENT | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View | |
EXPOSED WIRING | EXTERIOR NORTH WALL AND GAS SIGN | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | MOP SINK BASIN WALL WAS TAPPED TO USE AS DRAIN FOR CONDENSATE DRAIN. | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View | |
INSTALL COVERS | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View | |
ENGAG LIC & BOND PLMBNG CNTRC | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View | |
INDIRECT CONN.FOR WATER SUPPLY | SHOWER WAND CONNECTED TO BATHROOM TOILET WATER SUPPLY WITHOUT ANY MEANS OF POTABLE WATER CROSS CONTAMINATION PROTECTION. DANGEROUS AND HAZARDOUS . NO VISIBLE CROSS CONNECTION PROTECTION VISIBLE TO ICE MACHINE. | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View |
INSTALL GFCI'S | 7101 S ASHLAND AVE | COMPLAINT | FAILED | View | |
PROVIDE AIR CHAMERS | PROVIDE AIRCHAMBERS AT 3-COMPARTMENT SINK | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |
INSTALL WEATHERPROOF BOXES AND SATELLITE IN WALK IN COOLER ALL EQUIPMENT MUST BE WEATHERPROOF (18.27.370.15) | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View | |
PROVIDE TRAP FOR FIXTURE | PROPER STRAP UNDER EMPLOYEES LAVATORY | 7101 S ASHLAND AVE | COMPLAINT | PASSED | View |