The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEAT UNIT ADEQUATELY | NO HEAT - 1531 S KENNETH GARDEN APARTMENT 66 DEGREE | 1531 S KENNETH AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | DEFECTIVE FURNACE GARDEN APARTMENT | 1531 S KENNETH AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH AND NORTH ELEVATIONS/ EXTERIOR MASONRY WALLS - WASHED OUT MORTAR.NORTH ELEVATION/ VINYL SIDING - LOOSE. | 1531 S KENNETH AVE | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | CHIMNEY/ CAPPING - MISSING. | 1531 S KENNETH AVE | COMPLAINT | PASSED | View |
REPAIR ROOF | ROOF/ SHINGLES - MISSING, LOOSE AND CUPPED. | 1531 S KENNETH AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S I.D. SIGN NOT POSTED. | 1531 S KENNETH AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | FRONT 2-STORY WOOD PORCH RECENTLY BUILT WITHOUT PLANS SUBMITTED OR PERMIT OBTAINED. 6X6 COLUMNS RESTING ON CONCRETE PADS AND SERVICE WALK, FOUNDATION STATUS UNKNOWN. RIM JOISTS TO COLUMN CONNECTIONS FASTENED WITH SCREWS ONLY. SINGLE LEDGER BOARD MOUNTED TO WALL WITH MISSING BOLTS AND WITH ANCHORS SPACED UP TO 52". RISER HEIGHTS NOT UNIFORM, VARY FROM 4" TO 8". STRINGERS OVER NOTCHED WITH DEPTH OF STRINGERS AS LITTLE AS 1.75 INCHES. RAILINGS ONLY SCREWED TO COLUMNS. ENTIRE PORCH SYSTEM DEFLECTING UNDER LOAD.DANGEROUS AND HAZARDOUS CONDITIONS.PLANS AND PERMIT REQUIRED TO REPLACE FRONT 2-STORY PORCH. | 1531 S KENNETH AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON THE BUILDING. | 1531 S KENNETH AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | ENCLOSE PORCH NO SMOKE DETECTOR. | 1531 S KENNETH AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY MORTAR AND BRICKS; MISSING. | 1531 S KENNETH AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALLS; BROKEN BRICKS AND MORTAR MISSING. | 1531 S KENNETH AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | WEST BASEMENT RETAINING WALL; GUARD RAIL MISSING. | 1531 S KENNETH AVE | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO ATTIC AND 1ST FLR.[HAS ATTIC APARTMENT NO ENTRY BY TENANT]. | 1531 S KENNETH AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST PORCH; WOOD POST ROTTED,HAND RAILS LOOSE,GUARD RAIL IMPROPER HEIGHT,TREADS AND STRINGER WOOD SPLIT. ENCLOSE PORCH; 2X6 DECK JOIST AND RIM JOIST,GUARD RAIL HORIZONTAL PICKETS,STRINGER BROKEN,LEDGER BOARD PULLING AWAY FROM THE WALL,LOOKOUT ROTTED,2X4 DECK JOIST,INTERIOR WOOD WALL STUDS FRAMING ROTTED [SUBMIT PLANS AND PERMITS TO REPLACE]. | 1531 S KENNETH AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION WINDOW PANES; BROKEN. | 1531 S KENNETH AVE | COMPLAINT | FAILED | View |