Chicago Building Violations Data: 26 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR WALL ALL ELEVATION OPEN MORTAR JOINTS. 6032 S ELIZABETH ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH AND NORTH ELEVATION MISSING WIND0W PANES. 6032 S ELIZABETH ST COMPLAINT FAILED View
MAINTAIN WINDOW SASH SOUTH AND NORTH ELEVATION MISSING WIND0W SASHES. 6032 S ELIZABETH ST COMPLAINT FAILED View
MAINTAIN WINDOW SOUTH AND NORTH ELEVATION MISSING WIND0W FRAMES. 6032 S ELIZABETH ST COMPLAINT FAILED View
NOTIFY DOB, USE OF VACANT LND BUILDING IS VACANT AND SECURE. 6032 S ELIZABETH ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR NEED PLANS AND PERMITS FOR NEW PORCH AND REPAIRS ON BUILDING. 6032 S ELIZABETH ST COMPLAINT FAILED View
OBTAIN OR POST PERMIT 6032 S ELIZABETH ST COMPLAINT CLOSED View
MAINTAN BLDG IN SAFE CONDITION 6032 S ELIZABETH ST COMPLAINT CLOSED View
REPAIR/WRECK DANGER RESID PREM 6032 S ELIZABETH ST COMPLAINT CLOSED View
VACANT BUILDING - REGISTER 6032 S ELIZABETH ST COMPLAINT CLOSED View
POST OWNER INFO ON ABDN BLDG 6032 S ELIZABETH ST COMPLAINT CLOSED View
PROVIDE A/C UNITS PER PLANS AND PERMIT. 6032 S ELIZABETH ST PERMIT PASSED View
POST OWNER NAME OF VACNT BLDG VIOLATION CLOSED PER PCR 1180 6032 S ELIZABETH ST COMPLAINT CLOSED View
WORK NOT ALLOWED BASEMENT ALTERATION INTO DWELLING UNIT WITHOUT PERMIT IS IN PROGRESS.ENTIRE BASEMENT FRAMED WITH ELECTRICAL WIRING,PLUMBING AND NEW DUCKWORKS FOR HVAC. REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING ELECTRIC AND PLUMBING )INSTALLED IN BASEMENT WITHOUT PERMIT. 6032 S ELIZABETH ST COMPLAINT PASSED View
WATCHMAN 6032 S ELIZABETH ST COMPLAINT CLOSED View
ABANDONED REFRIGERATOR REAR YARD / ABANDONED REFG - 1ST FL PORCH LANDING . 6032 S ELIZABETH ST COMPLAINT PASSED View
ILLUMINATE PUBLIC STAIR/HALL 1ST FL FOYER / CEILING LIGHT - OUT SERVICE 6032 S ELIZABETH ST COMPLAINT PASSED View
STOP/REMOVE NUISANCE FRONT ELEVATION / NUISANCE -TRASH AND DEBRIS THOUGHT THE FLOOR . 6032 S ELIZABETH ST COMPLAINT PASSED View
NO POSTED ADDRESS FRONT / ADDRESS - NOT POSTED 6032 S ELIZABETH ST COMPLAINT PASSED View
REPAIR CATCH BASIN REAR / CATCH COVER - BROKEN 6032 S ELIZABETH ST COMPLAINT PASSED View
PROVIDE GUARD RAIL 42 IN HIGH FRONT / NEW GUARDRAIL -AT GRADE .TOP AND BOTTOM RAILS TOE NAILED ONLY 6032 S ELIZABETH ST COMPLAINT PASSED View
REPAIR FENCE SOUTH ELEVATION / WOODEN6FT FENCE - PICKETS BROKEN AND MISSING . 6032 S ELIZABETH ST COMPLAINT PASSED View
REPAIR EXTERIOR STAIR FRONT / EXTERIOR STAIR - BASEMENT TO GRADE .HANDRAIL MISSING 6032 S ELIZABETH ST COMPLAINT PASSED View
PROVIDE SOUTH ELEVATION / 2 STORY 3XX20 FT EXTERIOR OVER HANG - STONE AND BRICK. COLUMNS FOOTING UNKOWN ..COLUMNS AND I BEAM RUSTED .1ST FL 6 INCH IBEAM BENT AT END IN HALF .PROVIDE PER SECTION CODE 14A-6-603.3, 14A-6-603.3.2, 14A-6-603.3.3, 14A-6-603.3.4, SUBMIT EXTERIOR WALL CRITICAL EXAM 100% HAND-ON INSPECTION FOR (SOUTH ELEVATION FOR OVER HANG )SUBMIT TO ; DEPT OF BUILDING 2045 W WASHINGTON 6032 S ELIZABETH ST COMPLAINT PASSED View
REPLACE D&H PORCH 2-STORY REAR EXTERIOR WOOD PORCH IS IN DANGEROUS AND HAZARDOUS CONDITIONS.ALL COLUMNS ERECTED ON DIRT WITHOUT FOUNDATION- STATUS UNKNOWN.6X6 COLUMNS ARE OVER-NOTCHED AT BEAM-COLUMN CONNECTION GUARDRAIL SECTIONS ARE LOOSE AND PULLING WITH LOOSE,BROKEN AND MISSING PICKETS.DECK BOARDS LOOSE, ROTTING AND BROKEN AT DIFFERENT LOCATIONS.ENTIRE STRUCTURE IS WEAK AND DETERIORATING.PLANS AND PERMIT REQUIRED FOR REPLACEMENT OR REPAIRS. 6032 S ELIZABETH ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORKED TO AUTHORIZE ALTERATIONS IN BASEMENT OR RESTORE THE BUILDING TO ORIGINAL CONDITIONS. ALL WORK SUBJECT TO FIELD INSPECTIONS BT ALL RELATED TRADES. 6032 S ELIZABETH ST COMPLAINT PASSED View