Chicago Building Violations Data: 35 Violations
Violation Inspector Comments Address Category Status View
PRV HIGH SIDE 450 P.S.I.G. RE: ONE TECUMSEH 1-1/2 H.P. LOCATED IN THE BASEMENT IT SERVES A SIX DOOR RERACH IN COOLER. ONE COPELAND 1/2 H.P. LOCATED IN THE BASEMENT IT SERVES A THREE DOOR REACH IN COOLER. 10259 S MICHIGAN AVE PERIODIC FAILED View
REPLACE DEFECTIVE VALVE,PIPING CAP OPEN GAS LINE 1/2" 10259 S MICHIGAN AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM STAIR TO BASEMENT WEAK LOOSE TREAD, IMPROPER TREAD SIZE, UNSTABLE STAIR SYSTEM. 10259 S MICHIGAN AVE COMPLAINT PASSED View
SUBMIT STRUCT. ENG. RPT (INT.) BASEMENT TEMPORARY SHORING AT DIFFERENT LOCATIONS THROUGHOUT BASEMENT - STRUCTURAL ENGINEERING REPORT. 10259 S MICHIGAN AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID BASEMENT MISSING CARBON MONOXIDE DETECTOR 10259 S MICHIGAN AVE COMPLAINT PASSED View
DEBRIS, EXCESSIVE 2ND 10259 S MICHIGAN AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIRWAY TO 2ND FLOOR MISSING HANDRAIL 10259 S MICHIGAN AVE COMPLAINT PASSED View
REPAIR EXTERIOR DOOR BUILDING ENTRY DOOR TO 2ND FLOOR ROTTING WOOD WITH FLAKY PAINT 10259 S MICHIGAN AVE COMPLAINT PASSED View
NOTIFY DOB, USE OF VACANT LND 2ND FLOOR VACANT SPACE 10259 S MICHIGAN AVE COMPLAINT PASSED View
REPLACE DEFECTIVE WATER PIPING EMPLOYEE BATHROOMS - INSTALL AIR CHAMBERS ON WATER SUPPLY TO LAVATORY AND WATER CLOSET 10259 S MICHIGAN AVE COMPLAINT PASSED View
INSTALL TRAP,WASTE,VENT PIPES EMPLOYEE BATHROOMS - PROPERLY INSTALL SINK TRAP AND VENT FOR 2-COMPARTMENT SINK 10259 S MICHIGAN AVE COMPLAINT PASSED View
INSTALL INDIRECT CLEAR WASTE USE APPROVED MATERIALS FOR CONDENSATE WASTE LINES 10259 S MICHIGAN AVE COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE USE APPROVED MATERIALS FOR WATER HEATER PIPING 10259 S MICHIGAN AVE COMPLAINT PASSED View
PRV DISCHARGE PIPE FROM PRV USE APPROVED MATERIALS FOR WATER HEATER RELIEF VALVE DISCHARGE PIPING 10259 S MICHIGAN AVE COMPLAINT PASSED View
PROVIDE ADEQUATE SUPPORT INSTALL PROPER HANGERS ON 2" HORIZONTAL WASTE LINE BY COMPRESSOR 10259 S MICHIGAN AVE COMPLAINT PASSED View
OBTN PERMIT FOR PLUMBING WORK PULL A PLUMBING PERMIT FOR ALL PLUMBING WORK TO BE DONE. 10259 S MICHIGAN AVE COMPLAINT PASSED View
ENGAG LIC & BOND PLMBNG CNTRC HIRE A LICENSED PLUMBING CONTRACTOR 10259 S MICHIGAN AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS BASEMENT AND FRONT INTERIOR STAIRWAY MISSING SMOKE DETECTOR 10259 S MICHIGAN AVE COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY PADLOCKED NORTH ELEVATION REAR DOOR 10259 S MICHIGAN AVE COMPLAINT PASSED View
REPAIR EXTERIOR WALL EAST ELEVATION WALL AT GRADE WASHED OUT MORTAR 10259 S MICHIGAN AVE COMPLAINT PASSED View
SEE INSPECTOR COMMENTS EMPLOYEE BATHROOM - INSTALL GFCI RECEPTACLES IN ALL REQUIRED LOCATIONS (18-27-570.8) 10259 S MICHIGAN AVE COMPLAINT PASSED View
REMOVE************** BASEMENT (AT REAR) REMOVE UNAPPROVED MINI-BREAKERS IN ELECTRICAL CIRCUIT BREAKER PANELS (18-27-240.85) 10259 S MICHIGAN AVE COMPLAINT PASSED View
DEFECTIVE FIXTURES BASEMENT (NEAR ELECTRICAL PANELS) REPLACE IMPROPERLY INSTALLED PULL CHAIN LIGHT FIXTURE HANGING FROM WIRES. 10259 S MICHIGAN AVE COMPLAINT PASSED View
EXPOSED WIRING BASEMENT (BELOW ELECTRICAL PANELS) REMOVE EXPOSED WIRING AT COMPRESSORS FOR COOLERS 10259 S MICHIGAN AVE COMPLAINT PASSED View
CONTINUITY OF RACEWAY BASEMENT (BELOW ELECTRICAL PANELS) PROVIDE GROUND CONTINUITY FOR MOTORS AND METAL ENCLOSURES AT COMPRESSORS FOR COOLERS. NO METAL RACEWAY INSTALLED FOR WIRING BETWEEN MOTORS AND ENCLOSURES - NO GROUND CONITINUITY. 10259 S MICHIGAN AVE COMPLAINT PASSED View
ARMORED CABLE BASEMENT - REMOVE EXCESSIVE USE OF ARMORED CABLE NEAR ELECTRICAL PANELS AT REAR OF BASEMENT. 10259 S MICHIGAN AVE COMPLAINT PASSED View
BASEMENT - REMOVE ALL ABANDONED RACEWAYS NEAR ELECTRICAL PANELS AT REAR OF BASEMENT (18-27-110.12(E)) 10259 S MICHIGAN AVE COMPLAINT PASSED View
UNAPPROVED CORDS REMOVE EXTENSION CORD GOING THROUGH FLOOR BEHIND FRONT COUNTER ON 1ST FLOOR OF LIQUOR STORE. REMOVE EXCESSIVE USE OF EXTENSION CORDS NEAR ELECTRICAL PANELS IN BASEMENT. 10259 S MICHIGAN AVE COMPLAINT PASSED View
MULTIPLE CONDUCTOR TERM BASEMENT - REMOVE MULTIPLE CONDUCTOR TERMINATION AT METER SOCKET ENCLOSURE (DOUBLE - LUGGING) 10259 S MICHIGAN AVE COMPLAINT PASSED View
TYPE S FUSE BASEMENT - INSTALL TYPE "S" FUSES AT FUSE BOX ABOVE COMPRESSORS AT REAR OF BASEMENT. 10259 S MICHIGAN AVE COMPLAINT PASSED View
INSTALL COVERS BASEMENT - INSTALL COVER ON OPEN FUSE BOX NEAR ELECTRICAL PANELS AT REAR OF BASEMENT. 10259 S MICHIGAN AVE COMPLAINT PASSED View
SECURE RACEWAY PROPERLY STRAP AND SECURE ALL LOOSE OR IMPROPERLY SECURED RACEWAYS THROUGHOUT BASEMENT. 10259 S MICHIGAN AVE COMPLAINT PASSED View
WORKING SPACE BASEMENT - PROVIDE PROPER CLEARANCES FOR ELECTRICAL PANELS AT REAR OF BASEMENT (COMPRESSORS IN FRONT OF ELECTRICAL PANELS). 10259 S MICHIGAN AVE COMPLAINT PASSED View
PROVIDE PROPERLY SUPPORT ALL HORIZONTAL WATER LINES (18-29-303.2), (18-29-707.1) 10259 S MICHIGAN AVE COMPLAINT PASSED View
A REGISTERED ELECTRICAL CONTRACTOR SHALL OBTAIN AN ELECTRICAL PERMIT FOR ALL ELECTRICAL WORK TO BE PERFORMED. ELECTRICAL PERMITS SHALL BE OBTAINED BEFORE ANY WORK IS STARTED (18-27-570.4) 10259 S MICHIGAN AVE COMPLAINT PASSED View