Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PRV HIGH SIDE | 450 P.S.I.G. RE: ONE TECUMSEH 1-1/2 H.P. LOCATED IN THE BASEMENT IT SERVES A SIX DOOR RERACH IN COOLER. ONE COPELAND 1/2 H.P. LOCATED IN THE BASEMENT IT SERVES A THREE DOOR REACH IN COOLER. | 10259 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPLACE DEFECTIVE VALVE,PIPING | CAP OPEN GAS LINE 1/2" | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | STAIR TO BASEMENT WEAK LOOSE TREAD, IMPROPER TREAD SIZE, UNSTABLE STAIR SYSTEM. | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | BASEMENT TEMPORARY SHORING AT DIFFERENT LOCATIONS THROUGHOUT BASEMENT - STRUCTURAL ENGINEERING REPORT. | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | BASEMENT MISSING CARBON MONOXIDE DETECTOR | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | 2ND | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRWAY TO 2ND FLOOR MISSING HANDRAIL | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | BUILDING ENTRY DOOR TO 2ND FLOOR ROTTING WOOD WITH FLAKY PAINT | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
NOTIFY DOB, USE OF VACANT LND | 2ND FLOOR VACANT SPACE | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE WATER PIPING | EMPLOYEE BATHROOMS - INSTALL AIR CHAMBERS ON WATER SUPPLY TO LAVATORY AND WATER CLOSET | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
INSTALL TRAP,WASTE,VENT PIPES | EMPLOYEE BATHROOMS - PROPERLY INSTALL SINK TRAP AND VENT FOR 2-COMPARTMENT SINK | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
INSTALL INDIRECT CLEAR WASTE | USE APPROVED MATERIALS FOR CONDENSATE WASTE LINES | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | USE APPROVED MATERIALS FOR WATER HEATER PIPING | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | USE APPROVED MATERIALS FOR WATER HEATER RELIEF VALVE DISCHARGE PIPING | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
PROVIDE ADEQUATE SUPPORT | INSTALL PROPER HANGERS ON 2" HORIZONTAL WASTE LINE BY COMPRESSOR | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT FOR ALL PLUMBING WORK TO BE DONE. | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | BASEMENT AND FRONT INTERIOR STAIRWAY MISSING SMOKE DETECTOR | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | PADLOCKED NORTH ELEVATION REAR DOOR | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION WALL AT GRADE WASHED OUT MORTAR | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | EMPLOYEE BATHROOM - INSTALL GFCI RECEPTACLES IN ALL REQUIRED LOCATIONS (18-27-570.8) | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
REMOVE************** | BASEMENT (AT REAR) REMOVE UNAPPROVED MINI-BREAKERS IN ELECTRICAL CIRCUIT BREAKER PANELS (18-27-240.85) | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | BASEMENT (NEAR ELECTRICAL PANELS) REPLACE IMPROPERLY INSTALLED PULL CHAIN LIGHT FIXTURE HANGING FROM WIRES. | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
EXPOSED WIRING | BASEMENT (BELOW ELECTRICAL PANELS) REMOVE EXPOSED WIRING AT COMPRESSORS FOR COOLERS | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | BASEMENT (BELOW ELECTRICAL PANELS) PROVIDE GROUND CONTINUITY FOR MOTORS AND METAL ENCLOSURES AT COMPRESSORS FOR COOLERS. NO METAL RACEWAY INSTALLED FOR WIRING BETWEEN MOTORS AND ENCLOSURES - NO GROUND CONITINUITY. | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
ARMORED CABLE | BASEMENT - REMOVE EXCESSIVE USE OF ARMORED CABLE NEAR ELECTRICAL PANELS AT REAR OF BASEMENT. | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
BASEMENT - REMOVE ALL ABANDONED RACEWAYS NEAR ELECTRICAL PANELS AT REAR OF BASEMENT (18-27-110.12(E)) | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View | |
UNAPPROVED CORDS | REMOVE EXTENSION CORD GOING THROUGH FLOOR BEHIND FRONT COUNTER ON 1ST FLOOR OF LIQUOR STORE. REMOVE EXCESSIVE USE OF EXTENSION CORDS NEAR ELECTRICAL PANELS IN BASEMENT. | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
MULTIPLE CONDUCTOR TERM | BASEMENT - REMOVE MULTIPLE CONDUCTOR TERMINATION AT METER SOCKET ENCLOSURE (DOUBLE - LUGGING) | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
TYPE S FUSE | BASEMENT - INSTALL TYPE "S" FUSES AT FUSE BOX ABOVE COMPRESSORS AT REAR OF BASEMENT. | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
INSTALL COVERS | BASEMENT - INSTALL COVER ON OPEN FUSE BOX NEAR ELECTRICAL PANELS AT REAR OF BASEMENT. | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
SECURE RACEWAY | PROPERLY STRAP AND SECURE ALL LOOSE OR IMPROPERLY SECURED RACEWAYS THROUGHOUT BASEMENT. | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
WORKING SPACE | BASEMENT - PROVIDE PROPER CLEARANCES FOR ELECTRICAL PANELS AT REAR OF BASEMENT (COMPRESSORS IN FRONT OF ELECTRICAL PANELS). | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
PROVIDE | PROPERLY SUPPORT ALL HORIZONTAL WATER LINES (18-29-303.2), (18-29-707.1) | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |
A REGISTERED ELECTRICAL CONTRACTOR SHALL OBTAIN AN ELECTRICAL PERMIT FOR ALL ELECTRICAL WORK TO BE PERFORMED. ELECTRICAL PERMITS SHALL BE OBTAINED BEFORE ANY WORK IS STARTED (18-27-570.4) | 10259 S MICHIGAN AVE | COMPLAINT | PASSED | View |