Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR DOWNSPOUT | EAST ELEVATION /DOWNSPOUT - LOOSE AND HANGING; | 5232 W STRONG ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION /EXTERIOR FRAME WALL - VINYL SIDING - LOOSE; | 5232 W STRONG ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | REAR ELEVATION /EXTERIOR DOOR - TOO SMALL FOR FRAME; WITH GAPS AT TOP AND BOTTOM; | 5232 W STRONG ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | REAR ELEVATION /EXTERIOR DOOR HARDWARE - MISSING; | 5232 W STRONG ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | REAR 2 STORY ENCLOSED PORCH /SMOKE DETECTOR - MISSING; | 5232 W STRONG ST | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | 2ND. FL. APT. /SMOKE DETECTOR ¿ OUT OF SERVICE, WITH MISSING BATTERY; | 5232 W STRONG ST | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | 2ND. FL. APT. /CARBON MONOXIDE DETECTOR - MISSING; | 5232 W STRONG ST | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC APT. OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES; | 5232 W STRONG ST | COMPLAINT | CLOSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE ATTIC APT. WITHOUT PERMIT. | 5232 W STRONG ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR ELEVATION /2 STORY ENCLOSED WOOD PORCH;FOUNDATIONS /UNABLE TO INSPECT COLUMNS AT EXTERIOR - WALLS COVERED WITH DRYWALL - FOUNDATION STATUS UNKNOWN;COLUMNS, LEDGER BEAMS, BEAMS /UNABLE TO INSPECT - WALLS AND UNDER SIDE FOR DECK JOISTS COVERED WITH DRYWALL;STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS WEAK; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; NOTE: STAIRS FROM 1ST. FL. TO 2ND. FL. - BACK PITCHED;STAIRS /RISER HEIGHT NOT UNIFORMED, RANGING FROM 8 INCHES TO 3 INCHES; TREADS - RANGE FRON 9 INCHES TO11 INCHES;RAILINGS /GUARD RAILING SECTIONS ONLY 36 INCHES HIGH - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS ONLY 29 INCHES HIGH - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY; PICKETS /SPACED UP TO 7 1/2 INCHES APART AND MISSING;CONCENTRATED LOAD /ITEMS BEING STORED ON THE PORCH INCLUDE: PLASTIC CONTAINERS OF JUNK, REFRIGERATOR;PLANS AND PERMIT REQUIRED TO REPLACE: REAR ELEVATION /2 STORY ENCLOSED WOOD PORCH; | 5232 W STRONG ST | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | 1ST. FL. DOOR BELL /OUT OF SERVICE - KNOCKED, TENANT STATED SHE DOES NOT SPEAK ENGLISH - NO ENTRY TO 1ST. FL. AND BASEMENT; UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY;UNABLE TO INSPECT INTERIOR STAIRWAY; | 5232 W STRONG ST | COMPLAINT | CLOSED | View |