Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 8:04 PM
PIN: 13093210230000
Property Address: 5232 W STRONG ST
City - Zip: CHICAGO - 60630
2023 Property Class: 203
2023 Township: 71 - Jefferson
2023 Neighborhood: 71060
2023 Tax District: 71033
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 11 Violations
Violation Inspector Comments Address Category Status View
REPAIR DOWNSPOUT EAST ELEVATION /DOWNSPOUT - LOOSE AND HANGING; 5232 W STRONG ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL WEST ELEVATION /EXTERIOR FRAME WALL - VINYL SIDING - LOOSE; 5232 W STRONG ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR, RESET REAR ELEVATION /EXTERIOR DOOR - TOO SMALL FOR FRAME; WITH GAPS AT TOP AND BOTTOM; 5232 W STRONG ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE REAR ELEVATION /EXTERIOR DOOR HARDWARE - MISSING; 5232 W STRONG ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS REAR 2 STORY ENCLOSED PORCH /SMOKE DETECTOR - MISSING; 5232 W STRONG ST COMPLAINT CLOSED View
REPAIR/REPLACE SMOKE DETECTORS 2ND. FL. APT. /SMOKE DETECTOR ¿ OUT OF SERVICE, WITH MISSING BATTERY; 5232 W STRONG ST COMPLAINT CLOSED View
CARB MONOX DETECT IN RESID 2ND. FL. APT. /CARBON MONOXIDE DETECTOR - MISSING; 5232 W STRONG ST COMPLAINT CLOSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC APT. OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES; 5232 W STRONG ST COMPLAINT CLOSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE ATTIC APT. WITHOUT PERMIT. 5232 W STRONG ST COMPLAINT CLOSED View
REPAIR PORCH SYSTEM REAR ELEVATION /2 STORY ENCLOSED WOOD PORCH;FOUNDATIONS /UNABLE TO INSPECT COLUMNS AT EXTERIOR - WALLS COVERED WITH DRYWALL - FOUNDATION STATUS UNKNOWN;COLUMNS, LEDGER BEAMS, BEAMS /UNABLE TO INSPECT - WALLS AND UNDER SIDE FOR DECK JOISTS COVERED WITH DRYWALL;STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS WEAK; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; NOTE: STAIRS FROM 1ST. FL. TO 2ND. FL. - BACK PITCHED;STAIRS /RISER HEIGHT NOT UNIFORMED, RANGING FROM 8 INCHES TO 3 INCHES; TREADS - RANGE FRON 9 INCHES TO11 INCHES;RAILINGS /GUARD RAILING SECTIONS ONLY 36 INCHES HIGH - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS ONLY 29 INCHES HIGH - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY; PICKETS /SPACED UP TO 7 1/2 INCHES APART AND MISSING;CONCENTRATED LOAD /ITEMS BEING STORED ON THE PORCH INCLUDE: PLASTIC CONTAINERS OF JUNK, REFRIGERATOR;PLANS AND PERMIT REQUIRED TO REPLACE: REAR ELEVATION /2 STORY ENCLOSED WOOD PORCH; 5232 W STRONG ST COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION 1ST. FL. DOOR BELL /OUT OF SERVICE - KNOCKED, TENANT STATED SHE DOES NOT SPEAK ENGLISH - NO ENTRY TO 1ST. FL. AND BASEMENT; UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY;UNABLE TO INSPECT INTERIOR STAIRWAY; 5232 W STRONG ST COMPLAINT CLOSED View