Last Modification Date: 2024-10-23 @ 3:12 AM
PIN: 16091110370000
Property Address: 616 N LOCKWOOD AVE
City - Zip: CHICAGO - 60644
2023 Property Class: 205
2023 Township: 77 - West Chicago
2023 Neighborhood: 77013
2023 Tax District: 77001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 54 Violations
Violation Inspector Comments Address Category Status View
REPAIR DOOR HARDWARE 2NF FLR BEDROOM LOOSE DOOR KNOBS 616 N LOCKWOOD AVE COMPLAINT FAILED View
HEAT HABITABLE ROOM FURNANCE IN ATTIC NO WORKING 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPAIR DEFECTIVE DOWNSPOUT DOWNSPOUTS NOT CONNECTED TO SEWER IN BACK OF HOUSE (7-28-060) 616 N LOCKWOOD AVE COMPLAINT FAILED View
REMV OBSTR FROM DRAINAGE SYSTM BSMT. KIT WASTE LINE BACKING -UP INTO L/TUB CLEAN CATCH BASIN & R SEWER (18-29-102.3) 616 N LOCKWOOD AVE COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL BSMT L/TUB WET VENTED MUST RE-PIPE 616 N LOCKWOOD AVE COMPLAINT FAILED View
PRV FLOOR DRAIN WITH METAL STR PROVIDE FLOOR DRAIN IN BSMT WITHIN 5'-0" OF WATER HEATER (18-29-402.5) 616 N LOCKWOOD AVE COMPLAINT FAILED View
OBTAIN PERMIT FOR PLUMBING PROVIDE PERMITS FOR ALL PLUMBING WORK (13-12-080,13-32-010) 616 N LOCKWOOD AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC EMPLOY LICENSE & BONDED PLUMBING CONTRACTOR (18-29-106.1) 616 N LOCKWOOD AVE COMPLAINT FAILED View
INSTALL PROPER SIZE TRAP 2ND FLR NO P-TRAP ON LAV. IN B/ROOM(18-29-209) 616 N LOCKWOOD AVE COMPLAINT FAILED View
RESET LOOSE FIXTURE 2ND FLR B/ROOM LOOSE TOILET (18-29-102.3) 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR REAR STAIR RAILS NOT 42IN 616 N LOCKWOOD AVE COMPLAINT FAILED View
CHIMNEY FOUNDATION STONE WORK WASHED OUT MORTAR 616 N LOCKWOOD AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE FRONT ENTRY DOOR NO PEEPHOLE 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPAIR FLOOR ENTRY WAY FLOOR MIISING TILES 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPAIR FLOOR BASEMENT BROKEN CONCRETE FLOOR 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM BASEMENT STAIRS MISSING RISER 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS 1ST FLR SMOKE DETECTOR NEEDS BATTERY 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM INT STAIRS 1 TO 2 -MISSING BALUSTERS 616 N LOCKWOOD AVE COMPLAINT FAILED View
FLOOR, KIT & BATH NON-ABSORB BATHROOM FLR MISSING FLOOR TILES 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPAIR DOOR, INT. 2ND FLR BEDROOM-BROKEN DOOR 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPLACE DEFECTIVE VALVE,PIPING 2ND FLR B/ROOM BROKEN TUB HANDLE (18-29-102.3) 616 N LOCKWOOD AVE COMPLAINT FAILED View
PROVIDE HOT/COLD WATER TO SINK 2ND FLR B/ROOM HOT & COLD WATER CROSSED (13-196-420) 616 N LOCKWOOD AVE COMPLAINT FAILED View
OBTAIN PERMIT FOR PLUMBING FOR ALL WORK TO BE DONE(13-12-080)(13-32-010) 616 N LOCKWOOD AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC EMPLOY LICENSE & BONDED PLUMBER (18-29-106.1) 616 N LOCKWOOD AVE COMPLAINT FAILED View
STRAP SERVICE CONDUIT RESTRAP LOOSE SERVICE ENTRANCE CABLE 616 N LOCKWOOD AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS 18.250.50 INSTALL SERVICE GROUND TO LINE SIDE OF WATER MAIN 616 N LOCKWOOD AVE COMPLAINT FAILED View
VACANTBUILDING-REGISTER/SECURE 616 N LOCKWOOD AVE COMPLAINT FAILED View
VACANT BUILDING - REGISTER 616 N LOCKWOOD AVE COMPLAINT CLOSED View
VACANTBUILDING-REGISTER/SECURE 616 N LOCKWOOD AVE COMPLAINT CLOSED View
REPAIR PORCH SYSTEM FRONT 1 STORY WOOD PORCH/ COLUMNS - HALF LAP JOINTS ARE NAILED ONLY.RIM JOISTS - ROTTED AND ONLY NAILKED TO COLUMNS. ALL RAILINGS - LOOSE AND PULLING; ONLY NAILED TO COLUMNS.RAILINGS - ONLY 38 INCHES HIGH.DECK BOARDS - ROTTED THROUGHOUT.REAR 1-STORY WOOD PORCH/ COLUMNS - DOUBLE NOTCHED FOR RIM JOISTS AND HALF LAP JOINTS ARE NAILED ONLY. RIM JOISTS ONLY NAILED TO COLUMNS. DECK JOISTS ARE ONLY NAILED TO RIM JOIST, MISSING JOIST HANGERS. STRINGERS - UPPER ENDS INADEQUATELY SUPPORTED WITH NAILS ONLY; ONLY 4 INCHES OF DEPTH REMAINING. RAILINGS ONLY 33 INCHES HIGH; NAILED ONLY TO COLUMNS.PLANS AND PERMIT REQUIRED TO REPAIR FRONT AND REAR PORCHES. 616 N LOCKWOOD AVE COMPLAINT PASSED View
VACANT BUILDING - REGISTER 616 N LOCKWOOD AVE COMPLAINT CLOSED View
UNAPPROVED HEATING DEVICE BASEMENT - USING AUXILLARY HEATERS TO WARM APARTMENT 616 N LOCKWOOD AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS BASEMENT - SMOKE DETECTOR - MISSING 616 N LOCKWOOD AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT - CARBON MONOXIDE DETECTOR MISSING 616 N LOCKWOOD AVE COMPLAINT FAILED View
CEILING HEIGHT - 7' BASEMENT - CEILING HEIGHT IS ONLY 79 1/2". 616 N LOCKWOOD AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY REAR ELEVATION AT REAR YARD,BROKEN CONCRETE SERVICE WALK,UNEVEN SURFACE. 616 N LOCKWOOD AVE COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE BASEMENT WITHOUT A PERMIT. 616 N LOCKWOOD AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN A PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGIONAL STATE. 616 N LOCKWOOD AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING-FIRST FLOOR AND ATTIC,NO RESPONSE,UNVERIFIED DETECTORS ,CONDITIONS AND OCCUPANCY. 616 N LOCKWOOD AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING- NO OWNER'S ID SIGN POSTED. 616 N LOCKWOOD AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY FRONT SERVICE WALK- BROKEN CONCRETE,WITH HOLES. 616 N LOCKWOOD AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING- NO RESPONSE,UNVERIFIED DETECTORS. UNVERIFIED COMPLAINT OF BED BUGS/ROACHES AT APT. #2. 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT EXT STAIRS BROKEN 1ST 616 N LOCKWOOD AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION ENTRY REFUSED BY TENANT / OWNER - UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. 616 N LOCKWOOD AVE COMPLAINT PASSED View
WORK NOT ALLOWED BASEMENT - REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRICAL) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. 616 N LOCKWOOD AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR BASEMENT - SUBMIT PLANS AND OBTAIN PERMIT FOR ALL WORK RELATED TO AUTHORIZE CONVERSION OF BASEMENT INTO A DWELLING UNIT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 616 N LOCKWOOD AVE COMPLAINT FAILED View
ADDITIONAL EXIT BASEMENT - ONLY ONE MODE OF EGRESS - REAR 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR BASEMENT - EXTERIOR DOOR ROTTING AT BOTTON WITH HOLES 616 N LOCKWOOD AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE REAR YARD - SHOPPING CART, DEMO DEBRIS, TRASH IN REAR. 616 N LOCKWOOD AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY SERVICEWALK - BROKEN CONCRETE; UNEVEN AND PROTRUDING 616 N LOCKWOOD AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRAME 1ST FLOOR REAR ENTRY DOOR - ROTTING DOOR JAMB 616 N LOCKWOOD AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS BASEMENT - SMOKE DETECTOR - MISSING 616 N LOCKWOOD AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT - CARBON MONOXIDE DETECTOR - MISSING 616 N LOCKWOOD AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION UNABLE TO INSPECT 1ST & 2ND FLOOR APARTMENTS, ATTIC, STAIRWELLS, AND ENCLOSED REAR PORCH. UNVERIFIED DETECTORS AND CONDITIONS. 616 N LOCKWOOD AVE COMPLAINT FAILED View