The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SERVICE WALK, PASSAGE, AREAWAY | SIDE SERVICE WALK FRACTURES. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | NORTH/SOUTH WINDOWS PEELING PAINT. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR EXTERIOR DOOR AT GRADE ROTTED. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT WINDOW AT 1 BOARDED, ALL AROUND PROPERTY WINDOWS CRACKED AND BROKEN. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR PATIO AREA BROKEN GLASS. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | BUILDING V/S. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | FRONT LINTELS AT 1ST AND 2ND RUSTED, PEELING PAINT. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | ALL WINDOW SASH CRACKED. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ALL WINDOW ROTTED. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | ALL WINDOWS REPUTTY. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS, REAR ELEVATION AND REAR ENCLOSED PORCH. DOG IN REAR YARD; UNABLE TO ACCESS REAR PORCH. UNABLE TO VERIFY COMPLAINT OF UNSTABLE PORCH. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION/ EXTERIOR WALL - SPLLING BRICKS WITH WASHED OUT MORTAR (MINOR). | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH ELEVATION/ PARAPET WALL - SPALLING BRICKS WITH WASHED OUT MORTAR. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR YARD- OVERGROWN TREE,BRANCHES HITTING THE POWER LINE.BRANCHES HANGING OVER THE YARD TO THE SOUTH. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | REAR ENCLOSED TWO STORY PORCH,MISSING SMOKE DETECTOR. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALL,NORTH ELEVATION, SPALLED BRICKS,WASHED OUT MORTAR. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- BAEMENT APARTMENT. NO RESPONSE,UNVERIFIED DETECTORS. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING- NO OWNER'S ID SIGN POSTED. | 5654 N MENARD AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | BASEMENT APARTMENT- FRONT ROOM 64, BEDROOM 62. HEATING SYSTEM IS OFF AT TIME OF INSPECTION- NO HEAT PROVIDED. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | BASEMENT APARTMENT- NO PERMANENT HEATING SYSTEM FURNISHED. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
UNAPPROVED HEATING DEVICE | BASEMENT APARTMENT- UNVENTED GAS SPACE HEATER PROVIDED, SHUT OFF BY PEOPLES GAS. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | BASEMENT BOILER ROOM- MISSING SMOKE DETECTOR. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | BASEMENT BOILER ROOM- MISSING CARBON MONOXIDE DETECTOR. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | BASEMENT BOILER ROOM- MISSING SMOKE DETECTOR. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | BASEMENT BOILER ROOM- MISSING CARBON MONOXIDE DETECTOR. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BASEMENT BOILER ROOM CEILING- BROKEN AND MISSING SECTIONS OF PLASTER. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT EXTERIOR DOORKNOB- LOOSE. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
REPAIR DOOR, INT. | BASEMENT APARTMENT REAR EXIT DOOR- 1+3/8 INCH HOLLOW CORE DOOR. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | BASEMENT APARTMENT REAR EGRESS THROUGH DOORWAY ONLY 22+1/2 INCHES WIDE BY 6 FEET HIGH- HAZARDOUS CONDITION. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
INSTALL DEAD BOLT LOCK | BASEMENT APARTMENT FRONT AND REAR ENTRY DOORS- MISSING DEADBOLT LOCKS. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
INT WALL/CEILING PEELING PAINT | BASEMENT APARTMENT KITCHEN WALLS- MILDEW BUILDUP. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
STOP ODORS RPR DFT SEWAGE SYS | BASEMENT APARTMENT/ UNDER KITCHEN SINK- FOUL ODORS. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
INSTALL DOOR VIEWING DEVICE | BASEMENT APARTMENT ENTRY DOOR- MISSING VIEWING DEVICE. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT APARTMENT- SECTIONS OF CEILING ONLY 6 FEET HIGH. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED . | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES ( INCLUDING PLUMBING , ELECTRICAL AND VENTILATION ) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE . | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | FIRST FLOOR APARTMENT - SMOKE DETECTOR OUT OF SERVICE. | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | BASEMENT BOILER ROOM - SMOKE DETECTOR , NOT MOUNTED ONTO WALLS OR CEILING, PLACED ON WINDOW SILL . | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | BASEMENT BOILER ROOM - CARBON MONOXIDE DETECTOR , NOT MOUNTED ONTO WALLS OR CEILING , PLACED ON A WINDOW SILL . | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
1/2HR FLR OVER BSMT,3+DU,PRE57 | BASEMENT BOILER ROOM CEILING - BROKEN , MISSING SECTIONS OF PLASTER . | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
EXIT THROUGH BEDROOM/BATHROOM | BASEMENT APARTMENT - REAR EXIT THROUGH BEDROOM AND THROUGH BACK OF CLOSET WITH 22 INCH DOOR . FIRE AND SAFETY HAZARD . | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
REMV RARELY USED FIXTURE | BASEMENT APARTMENT - REMOVE SHOWER AND BASE FROM REAR BEDROOM AND SEAL SUPPLY AND DRAIN LINES . | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
CEILING HEIGHT - 7' | BASEMENT APARTMENT CEILING - SECTIONS ONLY SIX FOOT HIGH . | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | BASEMENT WALL MOUNTED FURNACE INSTALLED WITHOUT A PERMIT , SUBJECT TO FIELD INSPECTION AND APPROVAL BY HVAC BUREAU. | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
FOLLOW APPROVED PLANS | PERMIT #100624291 ISSUED 1/12/2016 FOR BASEMENT APARTMENT CONVERSION , WORK NOT COMPLETED TO APPROVED PLANS FOR WALL CONSTRUCTION AND WALL FINISH . CEILINGS REQUIRE ALL MATERIALS REMOVED TO FRAMING AND 5/8 FIRE RATED DRYWALL INSTALLED . EXISTING WALLS WITH WOOD PANELING NOT FIRE RATED . SR16-01076435 SENT TO VENTILATION FOR WALL FURNACE AND WATER HEATER FLUE PIPES . | 5654 N MENARD AVE | PERMIT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | 5654 N MENARD AVE | PERMIT | PASSED | View | |
PARAPET | NORTH ELEVATION /PARAPET - CRACKED, CRUMBLING PARGE COAT. | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | REAR ELEVATION - OVERGROWN TREE GROWING INTO POWER LINES [POTENTIAL FIRE HAZARD]. | 5654 N MENARD AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | MOST APARTMENTS- NO RESPONSE, UNVERIFIED DETECTORS, AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |
REPAIR DOOR FRAME, MULLION | BASEMENT APARTMENT REAR EXIT DOOR FRAME MISSING SECTIONS AT TOP. | 5654 N MENARD AVE | COMPLAINT | CLOSED | View |