The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR WINDOW SILLS | EAST ELEVATION - OPEN SILL JOINTS | 1942 N PULASKI RD | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | WEST ELEVATION - 2 STORY OPEN WOOD PORCH. 6X6 COLUMNS ARE OVERNOTCHED,FASTENED TO BEAMS WITH LIGHT GAUGE METAL BRACKETS AND ARE ERECTED ON TOP OF COLLAPSING FOUNDATION.2X8 JOISTS ARE SPANNING 12FT AND NAILED TO RIM JOISTS ON INTERMEDIATE LANDING.RAILINGS ARE 36" HIGH,LOOSE AND TOENAILED TO COLUMNS.TREADS AND DECK BOARDS ARE WORN.PLANS AND PERMIT REQUIRED FOR PORCH REPLACEMENT. | 1942 N PULASKI RD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE.UNABLE TO GAIN ENTRY TO BASEMENT APARTMENT TO VERIFY COMPLAINT OF MISSING DETECTORS AND OCCUPANCY. | 1942 N PULASKI RD | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | NORTH ELEVATION - FOUNDATION ALONG SIDE BASEMENT STAIRS - BULGING AND SHIFTING.PERMIT REQUIRED FOR FOUNDATION REPAIRS. | 1942 N PULASKI RD | COMPLAINT | FAILED | View |
REPAIR FENCE | NORTH ELEVATION - 22X7FT HIGH ROLLING WROUGHT IRON GATE INSTALLED WITHOUT A PERMIT.PLANS AND PERMIT NOW REQUIRED SUBJECT TO FIELD INSPECTION AND APPROVAL BY IRON BUREAU. | 1942 N PULASKI RD | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION - OPEN SILL JOINTS | 1942 N PULASKI RD | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | WEST ELEVATION - 2STORY PORCH. 6X6 COLUMNS ARE OVER NOTCHED , FASTENED TO BEAMS WITH LIGHT METAL GAUGE BRACKETS AND ARE ERECTED ON TOP OF COLLAPSING FOUNDATION. 2X8 JOISTS ARE SPANNING 12' AND NAILED TO RIM JOIST ON INTERMEDIATE LANDING. RAILINGS ARE 36" LOOSE AND TOE NAILED TO COLUMNS.PLANS AND PERMITS ARE REQUIRED. FOR PORCH REPAIRS .ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL. | 1942 N PULASKI RD | COMPLAINT | PASSED | View |
PROVIDE | NORTH REAR ELEVATION - 22X7' HIGH ROLLING WROUGHT IRON GATE/FENCE INSTALLED WITHOUT PERMIT. PERMIT REQUIRED SEC. 14A-4-404.7 IT IS UNLAWFUL TO ERECT A FENCE MORE THAN 5 FEET (1524 MM) IN HEIGHT WITHOUT FIRST OBTAINING A PERMIT FROM THE BUILDING OFFICIAL. | 1942 N PULASKI RD | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | WEST ELEVATION - BASEMENT STAIR FOUNDATION WALLS ARE BULGING AND SHIFTING. PERMIT REQUIRED FOR REPAIRS. | 1942 N PULASKI RD | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | NORTH , SOUTH AND EAST ELEVATIONS - FRACTURES , LOOSE AND ERODED MORTAR. | 1942 N PULASKI RD | COMPLAINT | PASSED | View |
REPAIR COPING | NORTH AND SOUTH ELEVATIONS - MISSING AND LOOSE COPINGS | 1942 N PULASKI RD | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | NORTH , SOUTH AND EAST ELEVATIONS - FRACTURES , LOOSE AND ERODED MORTAR. | 1942 N PULASKI RD | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | WEST ELEVATION - 2STORY PORCH. 6X6 COLUMNS ARE OVER NOTCHED , FASTENED TO BEAMS WITH LIGHT METAL GAUGE BRACKETS AND ARE ERECTED ON TOP OF COLLAPSING FOUNDATION. 2X8 JOISTS ARE SPANNING 12' AND NAILED TO RIM JOIST ON INTERMEDIATE LANDING. RAILINGS ARE 36" LOOSE AND TOE NAILED TO COLUMNS.PLANS AND PERMITS ARE REQUIRED. FOR PORCH REPAIRS .ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL. | 1942 N PULASKI RD | COMPLAINT | FAILED | View |