Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING NO OWNERS I D SIGN POSTED. | 7100 S PRAIRIE AVE | COMPLAINT | FAILED | View |
CHIMNEY | NORTH ELEVATION,WEST CHIMNEY,STEP FRACTURE. | 7100 S PRAIRIE AVE | COMPLAINT | FAILED | View |
USE SANITARY REFUSE CONTAINERS | NORTH ELEVATION,GARBAGE CONTAINERS OVER FLOWING WITH GARABAGE. | 7100 S PRAIRIE AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | WEST ELEVATION,REAR CONCRETE PARKING SLAB,CRACKED WITH HOLES,TRIP HAZARD. | 7100 S PRAIRIE AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | WEST EXTERIOR STAIRS GRADE TO BASEMENT RETAINING WALL,WASHED OUT MORTAR. | 7100 S PRAIRIE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | EAST INTERIOR STAIRS,MISSING SMOKE DETECTOR. | 7100 S PRAIRIE AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | 2ND FLOOR UNIT,HALLWAY CEILING,OPEN OUTLET. | 7100 S PRAIRIE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING NO ENTRY TO 1ST FLOOR UNIT,BASEMENT,TO CHECK OCCUPANCY,DETECTORS. | 7100 S PRAIRIE AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH ELEVATION ... PARAPETT WALL IS PROFOUNDLY TILTED BACK AT A 5 DEGREE ANGLE OVER THE ROOF. THIS CONDITION EXISTS ACROSS THE ENTIRE LENGTH OF THE NORTH ELEVATION (ROUGHLY 50 FEET). THE BRICKWORK AT THE BASE OF THIS PARAPETT WALL IS CONTRIBUTING TO THIS UNSTABLE PARAPETS' CONDITION IN THAT THERE ARE A LARGE AMOUNT OF LOOSE, DIPLACED BRICKS ACROOSS THE ENTIRE LENGTH OF THIS FACADE ... DANGEROUS AND HAZARDOUS. PLANS AND PERMITS REQUIRED FOR REPAIRS. | 7100 S PRAIRIE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION. THE BRICKWORK BELOW THE PARAPET WALL IS SEVERELY DEGRARDED. THERE ARE MULTIPLE LOOSE AND DISPLACED BRICKS. RAIN WATER PENETRATIION HAS BEEN PENETRATING BEHIND THE FACE BRICK FOR A CONSIDERABLE PERIOD OF TIME. THIS CONDITION, LEFT UNABATED, WILL CONTINUE TO DEGRADE THE MASONRY. ALREADY, NUMEROUS BRICKS HAVE BECOME DETACHED FROM THE BACK BRICK DUE TO FAILED MORTAR ADHESION. THIS CONDITION IS TO BE CONSIDERED DANGEROUS AND HAZARDOUS. PLANS AND PERMIT ARE REQUIRED FOR REPAIRS. | 7100 S PRAIRIE AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | NO MANAGEMENT SIGN POSTED. | 7100 S PRAIRIE AVE | COMPLAINT | PASSED | View |
INT WALL/CEILING CHIP PLASTER | 1ST FLOOR BATHROOM ... MOLD ON THE WALLS. ALSO ... THE 1ST FLOOR IS DUPLEXED INTO THE BASEMNT AS BASEMENT LIVING SPACE ... THE MOLD CONDITION IN THIS BASEMNT IS SO SEVERE THAT THE LIVING SPACE IS COMPLETELY UNINHABITABLE. | 7100 S PRAIRIE AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQUIRED | THE 1ST FLOOR APARTMENT HAS BEEN "DUPLEXED" INTO THE BASEMNT. THIS BASEMENT IS NOW LIVING SPACE WITH PARTION WALLS FORMING BEDROOMS AND AND BATHROOM. NO PLANS OR PERMITS ON FILE FOR THESE ALTERATIONS. | 7100 S PRAIRIE AVE | COMPLAINT | PASSED | View |
PROTECT SIDEWALK DURING CONST | PROVIDE PROTECTIVE SIDEWALK CANOPY ACROOS THE ENTIRE LENGTH OF THE NORTH ELEVATION OF THIS BUILDING ... DANGEROUS AND HAZARDOUS BRICKWORK EXISTS AT THIS NORTH ELEVATION. | 7100 S PRAIRIE AVE | COMPLAINT | PASSED | View |
REPAIR LINTELS | NORTH ELEVATION ... NUMEROUS RUSTED LINTELS ... REPLACE WITH NEW LINTELS. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 7100 S PRAIRIE AVE | COMPLAINT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | 7100 S PRAIRIE AVE | PERMIT | PASSED | View |