Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CUT OR REMOVE HIGH WEEDS | OVERGROWN. 18" HIGH. | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | LUMBER. | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES ROTTEN. | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN NOT POSTED. | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | COLUMNS SET ON CONCRETE SLAB - FOUNDATION STATUS UNKNOWN. BEAM ATTACHED TO COLUMN WITH NAILS ONLY. BEAM IS ROTTEN THRU - D&H. RIM JOISTS ATTACHED TO COLUMNS WITH NAILS ONLY. RIM JOIST 1 - 2 ROTTEN THROUGH D&H. DECK JOISTS ATTACHED TO RIM JOISTS WITH NAILS ONLY. STRINGER 1ST TO 2ND FLOOR SPLIT. DECKING ROTTEN AND LOOSE. 36" RAILS ATTACHED TO EXTERIOR WALL, COLUMNS AND POSTS WITH NAILS ONLY.PLANS AND PERMIT REQUIRED TO REPLACE D&H REAR 2-STORY OPEN WOOD PORCH. | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | SOUTH ELEVATION /CHIMNEY CAPPING - MISSING; | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION /1 STORY WOOD PORCH;COLUMNS /6X6 NOT ANCORED TO BASES;DECK JOISTS /FASTENED TO [LEDGER BEAMS, HEADER JOISTS, RIM JOISTS] WITH TOE NAILS ONLY;STRINGERS /UPPER ENDS OF STRINGERS INADEQUATE SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; LOWER ENDS OF STRINGERS INADEQUATE SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY;RAILINGS /GUARD RAILING SECTIONS ¿ LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS ¿ LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALLS WITH NAILS /SCREWS ONLY; REAR 2 STORY WOOD PORCH;TYPICAL CONSTRUCTION [FRONT AND REAR] PORCHES;FOUNDATION /6X6 COLUMN ERECTED ON TOP CONCRETE SLAB; FOUNDATION STATUS UNKNOWN;BEAMS /6X6 [ROOF] LOOK-OUT - STACKED ON TOP OF 6X6 COLUMN, FASENED WITH TOE NAILS ONLY; | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | SCHEDULE FINIAL INSPECTION FOR PERMIT # 100545204; ISSUED 12-03-14; | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S ID SIGN POSTED. | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | NEW FRONT AND REAR PORCHES -REAR -6X6 COLUMN SET ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN.2X12 BEAMS NAILED TO COLUMNS.2X10 JOIST NAILED TO BEAMS.STRINGERS NAILED TO SUPPORTS.GUARD AND HANDRAILS NAILED TO SUPPORTS.FRONT PORCH - ALL JOIST, BEAMS, GUARD AND HANDRAILS NAILED TO SUPPORTS.NEW PERMIT REQUIRED FOR REPAIRS. | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINT OF CEILING LEAKING IN UNIT 2. | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | SOUTH ELEVATION CHIMNEY - MISSING CAP. | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | CONCRETE BROKEN AND UNEVEN. | 7132 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
OPEN | 7132 S UNIVERSITY AVE | PERMIT | FAILED | View |