Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLACE D&H PORCH | REAR PORCH- GRADE TO 3RD ALL STRINGERS TREAD AND ESPECIALLY WINDERS ARE WEAK BOUNCY, HAVE BEEN BRACED UNDERNEATH AND GLUE EITH 2X4'S THAT ARE ALSO ROTTING WOOD SPLIT/SAGGING STAIRS AT GRADE LOW GUARDRAILS COLUMNS PULLING APART AND BOWED WITH SPLITS AT 3RD LEVEL DECKING ROTTING | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMITS AND PLANS FOR REBUILDING AND RESESIGNED A STRUDY SYSTEM | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR PLATFORM | REPAIR CONCRETE PLATFORM AT REAR NORTH SERVICE WALK IN REAR. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | OPEN MORTAR ON SILLS AT REAR 1ST/3RD. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | ARRANGE FOR INT. INSPECTION TO VERIFY OCCUPANCY AND DETECTORS | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP MGMT. SIGN OF FRONT. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REMOVE DOUBLE KEY LOCK FROM REAR GATE. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | INT. FOYER LOOSE PLASTER ON WALLS AND CEILING IN STAIRWELL | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | REPLACE MISSING PICKETS INT. 1ST TO 3RD. STABLIZING LOOSE TREADS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER PROPERTY FOR 2006,2007 | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | (900485827) REAR PORCH COLUMNS ARE SET ON ANDNOT CENTERED ON UNDERSIZED BASES,FOUNDATION STATUS IS UNKNOWN COLUMNS ARE TWISTED JOINT OF PLUMB.OVERCUT AT SOUTH BEAM CONNECTIONS,ONLY TWO BOLTSAND JAPS AT SPLICES. BEAMS ARE ONLY NAILED INTO THE COLLUMNS AND SEPERATING AT THE CONNECTIONS.STRINGERSARE ONLY NAILED INTO THE BUILDING,COLUMNS AND POSTS AND SEPERATING AT THE CONNECTIONS, NORTH STRINGER AT GRADE IS FRACTURED.NEWEL POSTS ARE OVER CUT AT SPLICE CONNECTIONS AND ONLY NAILED TOGETHER.WORN LOOSE TREADS AND RISERS ARE SEPERATING AT THE CONNECTIONS-TREADS ARE SUPPORTED BY 2X4 MEMBERS SCABBED TO THE BOTTOMS,NAILS ARE PROTRUDING OUT OFTHE TREADS.ONLY 36 INCH HEIGHT GUARDRAILS,MISSING INTERMEDIATE POSTS,DEFECT UPON LOAD,ONLY NAILED INTO THE BUILDING,LOOSEAT (1) AND (3).BROKEN HANDRAIL FROM (2) TO (3) IMPROPER CONNECTIONS - MOST MEMBERS ARE ONLY TOE NAILED TOGETHER WITH SEPERATION AT THE CONNECTIONS.MISSING ROOF ACCESS HATCH.SUBMIT PLANS AND OBTAIN PERMIT FOR REPLACEMENT.SIGN POSTED FOR DANGEROUS AND HAZARDOUS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH AND REAR SERVICE WALKS FRACTURED,SPALLED CONCRETE | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S ID SIGN IS NOT POSTED ON THE BUILDING ECTERIOR | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR GATE DOUBLE KEY LOCK | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | FRONT INTERIOR VESTIBULE AND STAIRWAY,WALLS AND CEILING LOOSE,BUCKLING UP,FRACTURED AND MISSING PLASTER | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRWAY MID LANDING ARE PITCHED DOWNWARD AND ARE SEPERATING FROM THE STRUCTURE,CAPS ALONG THE DECK BOARDS AND WALLS.LOOSE GUARDRAILS AT MID-LANDINGS.BROKEN AND MISSING PICKETS.SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS.SIGN POSTED FOR DANGEROUS AND HAZARDOUS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
PARAPET | FRONT PARAPET WALL MISSING BRICKS.OBTAIN PERMIT FOR REPAIRS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW SASH | FRONT AND NORTH,STORM WINDOW SASHES BROKEN AND MISSING.NORTH AND REAR- WORN WOODEN SASHES. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH BROKEN AND MISSING WINDOW PANES. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH EXTERIOR WALL ABOVE AREAWAY AT REAR- STEP FRACTURES. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | FRONT THRU REAR JUNK BICYCLES AND PARTS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
CHIMNEY | SOUTH CHIMNEY WASHED OUT MORTAR | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | REAR GUTTERS IS RUSTED THRU DOWNSPOUT IS RUSTED,BROKEN AT THE ELBOW AND DISCONNECTED FROM THE DRAIN. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT VESTIBULE ENTRY DOOR MISSING WINDOW PANE. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR PORCH AT (3) JUNK AND DEBRIS ON THE LANDING | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | (900485827) REAR PORCH COLUMNS ARE SET ON ANDNOT CENTERED ON UNDERSIZED BASES,FOUNDATION STATUS IS UNKNOWN COLUMNS ARE TWISTED JOINT OF PLUMB.OVERCUT AT SOUTH BEAM CONNECTIONS,ONLY TWO BOLTSAND JAPS AT SPLICES. BEAMS ARE ONLY NAILED INTO THE COLLUMNS AND SEPERATING AT THE CONNECTIONS.STRINGERSARE ONLY NAILED INTO THE BUILDING,COLUMNS AND POSTS AND SEPERATING AT THE CONNECTIONS, NORTH STRINGER AT GRADE IS FRACTURED.NEWEL POSTS ARE OVER CUT AT SPLICE CONNECTIONS AND ONLY NAILED TOGETHER.WORN LOOSE TREADS AND RISERS ARE SEPERATING AT THE CONNECTIONS-TREADS ARE SUPPORTED BY 2X4 MEMBERS SCABBED TO THE BOTTOMS,NAILS ARE PROTRUDING OUT OFTHE TREADS.ONLY 36 INCH HEIGHT GUARDRAILS,MISSING INTERMEDIATE POSTS,DEFECT UPON LOAD,ONLY NAILED INTO THE BUILDING,LOOSEAT (1) AND (3).BROKEN HANDRAIL FROM (2) TO (3) IMPROPER CONNECTIONS - MOST MEMBERS ARE ONLY TOE NAILED TOGETHER WITH SEPERATION AT THE CONNECTIONS.MISSING ROOF ACCESS HATCH.SUBMIT PLANS AND OBTAIN PERMIT FOR REPLACEMENT.SIGN POSTED FOR DANGEROUS AND HAZARDOUS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH AND REAR SERVICE WALKS FRACTURED,SPALLED CONCRETE | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | NORTH AND REAR WINDOW SILLS WASHED OUT MORTAR. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | FRONT INTERIOR VESTIBULE AND STAIRWAY,WALLS AND CEILING LOOSE,BUCKLING UP,FRACTURED AND MISSING PLASTER | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRWAY MID LANDING ARE PITCHED DOWNWARD AND ARE SEPERATING FROM THE STRUCTURE,CAPS ALONG THE DECK BOARDS AND WALLS.LOOSE GUARDRAILS AT MID-LANDINGS.BROKEN AND MISSING PICKETS.SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS.SIGN POSTED FOR DANGEROUS AND HAZARDOUS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
PARAPET | FRONT PARAPET WALL MISSING BRICKS.OBTAIN PERMIT FOR REPAIRS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW SASH | FRONT AND NORTH,STORM WINDOW SASHES BROKEN AND MISSING.NORTH AND REAR- WORN WOODEN SASHES. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH BROKEN AND MISSING WINDOW PANES. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR AREAWAY WALL | NORTH,AREAWAY CEILING SAGGING AND LOOSE PLASTER. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH EXTERIOR WALL ABOVE AREAWAY AT REAR- STEP FRACTURES. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | FRONT THRU REAR JUNK BICYCLES AND PARTS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | REAR GUTTERS IS RUSTED THRU DOWNSPOUT IS RUSTED,BROKEN AT THE ELBOW AND DISCONNECTED FROM THE DRAIN. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE WASHED OUT MORTAR,SPALLED BRICKS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT VESTIBULE ENTRY DOOR MISSING WINDOW PANE. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR PORCH AT (3) JUNK AND DEBRIS ON THE LANDING | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
CHIMNEY | SOUTH CHIMNEY WASHED OUT MORTAR | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING MANAGEMENT'S ID SIGN - NOT POSTED. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTRED FROM 2011 THROUGH 2016. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION / MULTIPLE LOCATIONS / WINDOW SILLS - WASHED OUT MORTAR. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. REAR YARD - LOCKED GATES, UNABLE TO INSPECT REAR PORCH. NO ENTRY FOR 2016 ANNUAL INSPECTION. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH-EAST CORNER / STONEWORK ABOVE 3RD FLOOR WINDOW - SEVERELY CRACKED AND SHIFTING. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | NORTH AND REAR WINDOW SILLS WASHED OUT MORTAR. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR AREAWAY WALL | NORTH,AREAWAY CEILING SAGGING AND LOOSE PLASTER. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE WASHED OUT MORTAR,SPALLED BRICKS. | 2444 N CAMPBELL AVE | PERIODIC | FAILED | View |