The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PLANS & PERMITS REQ - CONTRCTR | ORIGINAL GARAGE SERVICE STATION ALTERED WITHOUT PLANS OR PERMIT TO NOW EXISTING GARAGE SERVICE STATION PLUS TWO ADDITIONAL COMMERCIAL UNITS (BARBER SHOP AND UNLICENSED POOL HALL) BUILD OUT INCLUDES PARTITION WALLS ELECTRIC AND PLUMBING FIXTURES | 4700 W MADISON ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | EITHER OBTAIN APPROPRIATE PERMITS FOR 2 ADDITIONAL COMMERCIAL UNITS (BARBER SHOP POOL HALL) OR REMOVE ALL WORK PERFORMED WITHOUT SAID PERMIT | 4700 W MADISON ST | COMPLAINT | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | SERVICE STATION NO FIRE EXTINGUISHERS ALSO NONE AT THE BARBER SHOP POOL HALL | 4700 W MADISON ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | ALL 3-COMMERCIAL UNITS ARE WITHOUT CARBON MONOXIDE DETECTORS | 4700 W MADISON ST | COMPLAINT | FAILED | View |
MIXED OCCUPANCY SEPARATION | ORIGINAL GARAGE - SERVICE STATION ALTERED TO NOW EXISTING GARAGE - SERVICE STATION PLUS 2 ADDITIONAL MERCANTILE UNITS THIS CONFIGURATION CONSTITUTES A MIXED OCCUPANCY BUILDING AND THEREFORE REQUIRES ADDITIONAL FIRE SEPARATION CURRENT CONDITION NO APPROPRIATE FIRE SEPARATION MINIMUM 4 HOURS SEPARATION REQUIRED BETWEEN GARAGE SERVICE STATION AND THE TWO MERCANTILE UNITS | 4700 W MADISON ST | COMPLAINT | FAILED | View |
GARAGE TO RESIDENTIAL-4HR SEP | MIXED OCCUPANCY (CLASS J AND CLASS F) BUILDING ABSOLUTE CODE REQUIREMENT OF 4 HOUR FIRE SEPARATION BETWEEN THE GARAGE - SERVICE STATION (CLASS J) AND THE TWO MERCANTILE UNITS (CLASS F) | 4700 W MADISON ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PERMIT REQUIRED FOR FIRE SEPARATION PARTITIONS | 4700 W MADISON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO MANAGEMENT SIGN POSTED | 4700 W MADISON ST | COMPLAINT | FAILED | View |
CLASS B DOOR IN STAIRWELL | MIXED USE BUILDING CLASS J AND F PROVIDE CLASS (B) FIRE DOOR WITH SELF CLOSING DEVICE BETWEEN THE 3 COMMERCIAL SPACES | 4700 W MADISON ST | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | ALL EXTERIOR BRICK PAINT FAILURE PEELING PAINT | 4700 W MADISON ST | COMPLAINT | FAILED | View |
PROVIDE OPEN FRONT TOILET SEAT | PROVIDE OPEN FRONT SEATS AT MEN WATER CLOSET | 4700 W MADISON ST | COMPLAINT | FAILED | View |
PROV HOT WTR TO ALL FIXTURES | NO HOT WATER AT EMPLOYEES TOILET ROOM | 4700 W MADISON ST | COMPLAINT | FAILED | View |
PRV BALLCOCK,VB,OR AIR GAP | PROVIDE VACUUM BREAKERS 7'-6" ABOVE FINISHED FLOOR ATTACHED FOR EACH FAUCET OR SHAMPOO BOWLS | 4700 W MADISON ST | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | TO CORRECT ALL PLUMBING VIOLATIONS | 4700 W MADISON ST | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | A LICENSED & BONDED PLUMBING CONTRACTOR IS REQUIRED | 4700 W MADISON ST | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | BARBER SHOP MISSING CEILING TILES | 4700 W MADISON ST | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | SIDE LOT EXCESSIVELY HIGH WEEDS FIRE HAZARD | 4700 W MADISON ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | ON THIS LOT AT LEAST 30 ABANDONED AUTOMOBILES | 4700 W MADISON ST | COMPLAINT | FAILED | View |
CLOSE BOX OPENINGS | UNUSED OPENING ON ELECTRICAL PANEL 1ST FLOOR | 4700 W MADISON ST | COMPLAINT | FAILED | View |