The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | FRONT PORCH STAIR STRINGER OVER NOTCHED, NOT PROPERLY ATTACHED; JOISTS ARE UNDERSIZED FOR SPAN; SCAB WOOD ADDED TO JOISTS; DECK BOARDS DETACHED FROM JOISTS; DECKING ROTTED, BUCKLED AND LOOSE; COLUMN FOOTINGS UNVERIFIED ; METAL HANDRAILS LOOSE; METAL GUARDRAIL LESS THAN 42" HIGH; PERMIT REQUITED FOR REPAIRS TO PORCH. | 5742 S TRUMBULL AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | NORTH ELEVATION GUTTER DEFECTIVE WATER IS DRAINING AT THE CENTER JOINT. | 5742 S TRUMBULL AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR HARDWARE | REAR BASEMENT WINDOW MISSING PANE. | 5742 S TRUMBULL AVE | COMPLAINT | CLOSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR ATTIC LEVEL NO GUARDRAIL AT EXTERIOR DOOR, ROOF LEVEL. | 5742 S TRUMBULL AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | REAR BRICK GARAGE-NORTH WALL SPALLING BRICKS; WASHED OUT MORTAR; DOWNSPOUTS MISSING. | 5742 S TRUMBULL AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR AT AT TIME OF INSPECTION; UNVERIFIED SMOKE DETECTORS AND OCCUPANCY. | 5742 S TRUMBULL AVE | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | NO MANAGEMENT SIGN POSTED ON BUILDING. | 5742 S TRUMBULL AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | FRONT PORCH STAIR STRINGER OVER NOTCHED, NOT PROPERLY ATTACHED; JOISTS ARE UNDERSIZED FOR SPAN; SCAB WOOD ADDED TO JOISTS; DECK BOARDS DETACHED FROM JOISTS; DECKING ROTTED, BUCKLED AND LOOSE; COLUMN FOOTINGS UNVERIFIED ; METAL HANDRAILS LOOSE; METAL GUARDRAIL LESS THAN 42" HIGH; PERMIT REQUITED FOR REPAIRS TO PORCH. | 5742 S TRUMBULL AVE | COMPLAINT | CLOSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR ATTIC LEVEL NO GUARDRAIL AT EXTERIOR DOOR, ROOF LEVEL. | 5742 S TRUMBULL AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE; NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELL, APARTMENTS, BASEMENT, ATTIC, AND ENCLOSED REAR PORCH. UNVERIFIED DETECTORS AND OCCUPANCY. | 5742 S TRUMBULL AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT PORCH - FOUNDATION STATUS UNKNOWN; 2X6 JOISTS SPAN 8'-3"; LOOSE METAL HANDRAILS. PLANS AND PERMIT REQUIRED TO REPAIR FRONT STAIR SYSTEM. | 5742 S TRUMBULL AVE | COMPLAINT | PASSED | View |
INSPECT CONSTRUCTION WORK | RECENTLY REPAIRED/BUILT FRONT PORCH. PLANS AND PERMIT NOT AVAILABLE FOR REVIEW AT TIME OF INSPECTION. | 5742 S TRUMBULL AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN-NOT POSTED. | 5742 S TRUMBULL AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT PORCH-STRINGERS ARE OVERCUT AT EDGE BEAM AND ONLY NAILED INTO THE COLUMN CONNECTIONS. LOOSE HANDRAILS. | 5742 S TRUMBULL AVE | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | ATTIC LEVEL-ROOF ACCESSIBLE THRU EXTERIOR DOOR; MISSING FALL PROTECTION. OBTAIN PERMIT FOR INSTALLATION OF GUARDRAIL. | 5742 S TRUMBULL AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR-NO RESPONSE; UNVERIFIED COMPLAINT OF: SR#121110480-(BASEMENT / ATTIC) ILLEGAL APARTMENT; NO SMOKE ALARMS; NO ADDITIONAL MEANS OF EGRESS. | 5742 S TRUMBULL AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR BASEMENT WINDOW MISSING PANE. | 5742 S TRUMBULL AVE | COMPLAINT | CLOSED | View |