FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2004 THRU 2008 | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS AT NORTHEAST BREEZEWAY-MISSING HANDRAIL 2 REAR EXTERIOR STAIR SYSTEMS (CONDITIONS TYPICAL)-4X4 COLUMNS USED FOR SUPPORT OVER 12 FEET HIGH. 4X4 COLUMNS RESTING ON CONCRETE SLAB. FOUNDATION STATUS UNKNOWN. 4X4 COLUMNS WITH BOLT JOINTS, STRINGERS INADEQUATELY SUPPORTED. RAILINGS TOO LOW. STAIR TREADS WITH EXCESSIVE WEAR AND BROKEN. LOOSE DECKING, RAILINGS TOO LOW. PLANS AND PERMIT REQUIRED. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH-6X6 COLUMNS RESTING ON CONCRETE SLAB-FOUNDATION STATUS UNKNOWN. LOOKOUT BEAMS MISSING TIE STRAPS. 1ST FLOOR LOOKOUT BEAMS BEARING ON 2X4'S THAT BEAR ON TOP OF WINDOW SILL. 2X8 JOIST OVER SPANNED (16+FEET). INADEQUATE BEAM COLUMN CONNECTION, STRINGERS INADEQUATELY SUPPORTED. STAIR TREADS TOO SMALL, RAILINGS TOO LOW. STAIRS ONLY 31 INCHES WIDE, PLANS AND PERMIT REQ. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST ELEVATION/SERVICE WALK-BUCKLED AND SUNKEN CONCRETE | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
DEFECTIVE OUTLETS | BROKEN WALL OUTLET 1626 APT IS IN THE KITCHEN | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | BROKEN DOOR LOCK-REAR EXIT DOOR | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | SCREEN DOOR BROKEN 1626 APT IS UNABLE TO LOCK THE DOOR | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST ELEVATION/SERVICE WALK-BUCKLED AND SUNKEN CONCRETE | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION THREE STORY PORCH, 6X6 COLUMNS REST ON CONCRETE BLOCKS, FOUNDATION STATUS UNKNOWN. 6X6 COLUMNS TWISTING. EXTERIOR BEAMS SEVERLEY SAGGING AT ALL LEVELS, 6X6 LOOK-OUT BEAMS SEPERATING AND NAILED ONLY.2X8 JOISTS OVER SPAN 15'4,2X8 JOIST AGINST MASONARY WALLS NAILED ONLY.STRINGER CONNECTIONS NAILED ONLY. RAILING SECTIONS CONNECTIONS TO MASONARY WALLS NAILED ONLY. PLANS AND PERMIT REQUIRD FOR REPLACEMENT. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | NORTHEAST ELEVATION STAIR SYSTEM,4X4 COLUMNS REST ON CONCRETE SLAB,FOUNDATIONSTATUS UNKNOWN. STRINGER CONNECTIONS TO MASONARY WALLS NAILED ONLY. HAND RAILS MISSING AT MASONARY WALLS. PLANS AND PERMIT REQUIRED FOR REPLACEMENT. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | NO BUILDING REGISTRATION. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE TO MOST APARTMENTS IN ORDER TO VERIFY DETECTORS. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | EAST ELEVATION/ALL FLOORS-MISSING SCREEN DOORS OR TORN SCREENS | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY - SPALLED BRICK SECTIONS WITH WASHED OUT MORTAR. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF HOLE IN CEILING AT APT 2. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
REPAIR CORNICE | WEST ELEVATION /CORNICE - WASHED OUT MORTAR JOINTS. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
PARAPET | FRONT ELEVATION /PARAPET - MASONRY FRACTURES WITH OPEN MORTAR JOINTS. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | FRONT AND WEST ELEVATIONS /EXTERIOR WALL - MASONRY DEFLECTIONS NEAR WINDOW LOCATIONS [MULTIPLE LOCATIONS]. | 1622 W SHERWIN AVE | PERIODIC | FAILED | View |