Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VACANTBUILDING-REGISTER/SECURE | BL00831 | 6909 S INDIANA AVE | COMPLAINT | PASSED | View |
VACANT BUILDING - REGISTER | BL00831 | 6909 S INDIANA AVE | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | BL00831 | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S ID SIGN NOT POSTED. | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED YEARS 2008 THRU 2011. | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
REPAIR COPING | WEST COPING STONES - WASHED OUT MORTAR. | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION - STEP FRACTURES.EAST, NORTH AND SOUTH ELEVATIONS - WASHED OUT MORTAR. | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WEST AND SOUTH ELEVATIONS, WINDOW SILLS - WASHED OUT MORTAR. | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | NORTH TWO STORY PORCH, EAST COLUMN ERECTED ON TOP OF A STONE; FOUNDATION STATUS UNKNOWN.EAST COLUMN HAVE INADEQUATE HALF-LAP JOINTS WITH OVERLAPS OF ONLY 8".EAST COLUMN - OVER NOTCHED AT RIM JOISTS CONNECTIONS.EAST COLUMN - SETTLED.LEDGER BOARD FASTENED TO BUILDING WITH NAILS ONLY.UNDERSIZED 6"X6" BEAM SPAN 6'-7".2ND FLOOR BEAM - PULLING OUT OF COLUMN FIRE CUT ( HAVE A 1-1/2" OPEN GAP). CREATING A DANGEROUS AND HAZARDOUS CONDITION.BEAMS ARE FASTENED TO COLUMNS WITH NAILS ONLY.UNDERSIZED 2"X8" DECK JOISTS SPAN 10'-11".RIM JOISTS AND DECK JOISTS WALLS POCKETS - MORTAR MISSING.LANDING JOISTS FASTENED TO RIM JOISTS WITH NAILS ONLY; LANDING HEADER JOIST IS ROTTED.LANDING IS PULLING AWAY FROM WALL.STRINGERS INADEQUATELY SUPPORTED AT JOISTS AND 4"X4" RAILINGS POSTS (FASTENED WITH NAILS ONLY).STAIRS TREADS AND RISERS ARE LOOSE AND BROKEN; TREADS - ONLY 9-3/8" WIDE.DECKING BOARDS - BROKEN WITH JOLES AND LOOSE.GUARD AND STAIR RAILINGS SECTIONS ARE LOOSE AND PULLING, ONLY 39" HIGH AND FASTENED TO COLUMNS, 4"X4" RAILINGS POSTS AND EXTERIOR WALLS WITH NAILS ONLY.PLANS AND PERMIT ARE REQUIRED TO REPLACE D&H PORCH. | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
RELOCATE SMOKE DETECTOR | FRONT INTERIOR STAIRWAY - SMOKE DETECTOR INSTALLED ON THE 1ST FLOOR. | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | WEST BASEMENT - MISSING CARBON MONOXIDE DETECTOR. | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT CEILINGS - PLASTER HAS HOLES. | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | UNIT 1W NO CARBON MONOXIDE DETECTOR | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER 4 UNITS | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | MISSING COVER IN LIVING ROOM FRONT APARTMENT !ST FLOOR | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | BROKEN GFCI RECEPTACLE IN BATHROOM 1ST FLOOR FRONT APARTMENT | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
TENANT ACCESS TO SERVICE | PROVIDE FOR ALL TENANTS | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
CORRODED CONDUIT & EQUIP | SERVICE ENTRANCE CONDUITS ON EXTERIOR | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | BUILDING INFESTED WITH MICE INCLUDING APT. 6909-1W. | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | BASEMENT - REFUSE AND JUNK ACCUMULATION. | 6909 S INDIANA AVE | COMPLAINT | FAILED | View |